SIRCHCS003Test blood pressure and advise on self-monitoring

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for SIRCHCS003 must cover

69 assessable components: 4 elements (20 performance criteria), 10 performance evidence and 37 knowledge evidence requirements, plus 2 foundation skills. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Identify customer needs.

  • 1.1Follow organisational procedures to respect and protect customer privacy.
  • 1.2Question and actively listen to confirm customer needs.
  • 1.3Explain features of initial and repeat blood pressure testing services.
  • 1.4Identify and act on triggers for referral to pharmacist.

2 Test blood pressure.

  • 2.1Follow organisational procedures for testing blood pressure.
  • 2.2Explain limitations of single test as accurate indicator and suggest regular monitoring.
  • 2.3Select quiet and comfortable area and allow customer to relax before testing.
  • 2.4Select blood pressure testing instrument and appropriate cuff size and clearly explain testing procedure to customer.
  • 2.5Apply cuff and use testing instrument according to manufacturer instructions to test pulse, systolic blood pressure and diastolic blood pressure.
  • 2.6Repeat procedure to check accuracy.
  • 2.7Read test results, enter accurate and complete information on testing record and refer to pharmacist for verification.
  • 2.8Provide confirmed record to customer and file copy.

3 Support use of home blood pressure testing equipment.

  • 3.1Follow organisational procedures for supplying home blood pressure testing equipment.
  • 3.2Identify and recommend equipment appropriate to customer needs and clearly explain its features.
  • 3.3Demonstrate use, care and maintenance of digital home blood pressure testing equipment and confirm customer understanding.
  • 3.4Assist customer to identify self-testing strategies to achieve accurate readings.
  • 3.5Show customer how to keep a blood pressure record.

4 Provide information and advice on blood pressure management.

  • 4.1Encourage customer to take and record regular blood pressure readings and report to their doctor.
  • 4.2Advise customer to calibrate home testing equipment against doctor’s equipment reading every six months.
  • 4.3Source, review and provide customers with information on lifestyle, self-care practices and availability of specialist services that support blood pressure management.

Performance evidence

  • access and interpret information on blood pressure conditions and specialist support services from two sources
  • test blood pressure for four different customers
  • demonstrate, recommend and sell home blood pressure testing equipment to two different customers
  • for each customer sale, provide information on:
  • directions for product use
  • care and maintenance of home blood pressure testing equipment
  • self-testing strategies to achieve accurate readings at home
  • format, content and use of customer personal blood pressure records
  • lifestyle and self-care practices
  • specialist services that support blood pressure management.

Knowledge evidence

  • sources of information on blood pressure conditions and specialist support services:
  • federal, state or territory government health education internet sites
  • not for profit health councils
  • industry and professional publications
  • product manufacturer health education materials
  • common symptoms of high and low blood pressure
  • common lifestyle factors that can contribute to or exacerbate abnormal blood pressure and methods of self-care
  • meaning of:
  • systolic blood pressure
  • diastolic blood pressure
  • range of normal blood pressure levels
  • key terminology, jargon and common abbreviations relevant to blood pressure, for:
  • testing and recording blood pressure levels
  • pharmacy and home blood pressure testing equipment
  • pharmacy product range of home blood pressure testing equipment:
  • location
  • different types
  • features and uses
  • care and maintenance
  • customer self-testing strategies to achieve accurate readings at home
  • format, content and use of:
  • pharmacy blood pressure testing records
  • customer personal blood pressure records
  • sources and format of product, lifestyle and self-care information:
  • manufacturer product support materials:
  • Consumer Medicines Information (CMI)
  • product leaflets, brochures, booklets
  • internet sites
  • health-care fact sheets
  • pharmacy manuals
  • reputable health education internet sites; government and not-for profit organisations
  • role boundaries and responsibilities of pharmacy assistants, and circumstances which require and trigger referral to a pharmacist
  • organisational procedures for testing blood pressure and supplying home blood pressure testing equipment:
  • questions that must be asked to collect information about customer needs
  • identifying and acting on triggers for referral to a pharmacist
  • maintaining privacy and confidentiality of customer information
  • recording and maintaining readings and requirements for pharmacist verification.

Foundation skills

  • Numeracy skills: work with numerical concepts about blood pressure levels and calibration requirements for home blood pressure testing equipment.
  • Technology skills: use online information systems to search for information.

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing SIRCHCS003

What does an assessment tool for SIRCHCS003 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for SIRCHCS003 needs to address all 69 unit components: 4 elements with 20 performance criteria, 10 performance evidence requirements, 37 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for SIRCHCS003?

Auditori pulls the current release of SIRCHCS003 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for SIRCHCS003 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing SIRCHCS003 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of SIRCHCS003, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your SIRCHCS003 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate SIRCHCS003 free