UETDRRC006 — Perform low voltage electricity network switching in a very remote community
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UETDRRC006 must cover
92 assessable components: 4 elements (27 performance criteria), 22 performance evidence and 43 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to perform LV electricity network switching
- 1.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are referred to and confirmed
- 1.2Work plan is obtained and confirmed in accordance with workplace requirements
- 1.3Hazards are identified, risks assessed and control measures identified and applied
- 1.4Plant, tools, equipment and PPE required for work are determined, obtained and confirmed in working order
- 1.5Switching schedule is developed in accordance with work plan and workplace requirements
- 1.6LV network switching is prioritised for completion in accordance with workplace requirements
- 1.7LV network switching schedule is communicated with relevant personnel in accordance with workplace requirements
2 Perform isolation of LV electricity network
- 2.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are applied and monitored
- 2.2Authorisation is obtained to commence LV electricity network switching in accordance with switching schedule and workplace requirements
- 2.3Lifting, climbing, working at heights and the use of plant, tools and equipment are carried out in accordance with workplace requirements
- 2.4Hazard control measures are monitored in accordance with workplace requirements
- 2.5LV electricity network is isolated in accordance with switching schedule
- 2.6Communications are maintained with authorisation authority in accordance with workplace requirements
- 2.7LV electricity network is tested to confirm de-energised and earthed/short circuited in accordance with switching schedule and workplace requirements
- 2.8Incidents or unplanned events are responded to in accordance with workplace requirements
- 2.9Work permits are received and signed in accordance with workplace requirements
- 2.10Authorisation authority is notified isolation is completed in accordance with switching schedule and workplace requirements
3 Perform restoration of LV electricity network
- 3.1Work permits are signed off in accordance with switching schedule and workplace requirements
- 3.2Authorisation is obtained to commence restoration of LV electricity network in accordance with workplace requirements
- 3.3Lifting, climbing, working at heights and the use of plant, tools and equipment, are carried out in accordance with workplace requirements
- 3.4Restore LV electricity network in accordance with switching schedule
- 3.5Authorisation authority is notified restoration is completed in accordance with switching schedule and workplace requirements
4 Complete work and documentation
- 4.1Completed work is checked for compliance against the work plan and workplace requirements
- 4.2Incidents or unplanned events are reported in accordance with workplace requirements
- 4.3Worksite is rehabilitated, cleaned and made safe in accordance with workplace requirements
- 4.4Plant, tools and equipment are cleaned, checked and returned to storage in accordance with workplace requirements
- 4.5Work records, reports and documentation are completed, and appropriate personnel notified in accordance with workplace requirements
Performance evidence
- Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria on at least two separate occasions and include:
- applying relevant legislation, regulations, standards, codes of practice and organisational workplace requirements, including:
- relevant work health and safety (WHS)/occupational health and safety (OHS)
- identifying hazards, assessing risks, identifying, applying and monitoring control measures
- obtaining, inspecting and using relevant personal protective equipment (PPE)
- obtaining and signing on and off relevant work permits in accordance with workplace requirements
- preparing a low voltage (LV) electricity network switching schedule in accordance with workplace requirements
- obtaining authorisation to perform LV electricity network switching
- isolating and restoring LV electricity networks in accordance with switching schedule requirements
- undertaking tests of LV electricity network, including:
- voltage
- phase sequence (rotation)
- polarity
- operating LV switchgear, including at least one (1) of the following:
- LV circuit breaker
- LV links
- LV fuses
- working from at least one (1) of the following:
- elevated work platform (EWP)
- ladder
- dealing with an unplanned event on at least one (1) occasion
- completing relevant work records, reports and documentation.
Knowledge evidence
- Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria and include knowledge of:
- relevant legislation, regulations, standards, codes of practice and organisational workplace requirements, including:
- WHS/OHS
- hazard, risk assessment and risk control requirements, including potential hazards
- types and application of PPE
- safe use of plant, tools and equipment
- application, purpose and types of permits
- requirements for the use of manuals, system diagrams/plans and drawings, including:
- types, characteristics and capabilities of electrical apparatus
- use, characteristics and capabilities of specialised tools and testing equipment
- restrictions pertaining to LV switching equipment
- high voltage (HV) network interconnectors source of possible back-feed
- LV switchgear, including:
- types
- categories
- application
- function
- operating capabilities
- types, characteristics and capabilities of LV specialised switching and testing equipment
- procedures for obtaining correct LV switching authorisation, including:
- identification of hazards, assessing and controlling risks
- safety procedures and precautions
- safe approach distances
- responsibilities and protocols
- identifying switching resources
- procedures for obtaining electrical access permits/authorities
- requirements for team switching
- procedures for coordination of operations
- techniques for overhead and underground LV electricity network switching, including:
- isolation procedures
- testing and earthing/short circuiting LV electrical apparatus
- pre-switching checks
- switching operational procedures
- emergency fault procedures
- restoration procedures
- role and responsibilities of the LV switching operator
- application, function and operating capabilities of switchgear
- preparation of a LV switching schedule, including:
- legislation, standards, codes, supply authority regulations and/or enterprise requirements applicable to switching sheet schedules
- requirements for the use of manuals, system diagrams/plans and drawings - types, characteristics and capabilities of LV electrical equipment to be switched; isolation points and earthing; and responsibilities of the switching operator
- techniques in writing switching schedules - sequence of switching operations, isolation procedures, earthing procedures and switching completion notification procedures
- events constituting an unplanned event or incident
- procedures for responding to an unplanned event or incident.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UETDRRC006
What does an assessment tool for UETDRRC006 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UETDRRC006 needs to address all 92 unit components: 4 elements with 27 performance criteria, 22 performance evidence requirements, 43 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UETDRRC006?
Auditori pulls the current release of UETDRRC006 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UETDRRC006 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UETDRRC006 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UETDRRC006, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UETDRRC001 — Install and maintain low voltage overhead services in a very remote community
- UETDRRC002 — Install and maintain low voltage underground services in a very remote community
- UETDRRC003 — Install and maintain public lighting systems in a very remote community
- UETDRRC004 — Install and replace energy meters and associated equipment in a very remote community
- UETDRRC005 — Maintain, test and verify power systems in a very remote community
- UETDRRC007 — Solve problems in electrical network apparatus in a very remote community
- UETDRRC008 — Solve problems in low voltage electrical network circuits in a very remote community
- UETDRRT001 — Install overhead rail traction configurations
- UETDRRT002 — Install overhead traction components and equipment
- UETDRRT003 — Install rail traction bonds
- UETDRRT004 — Install traction overhead wiring systems
- UETDRRT008 — Maintain overhead rail traction configurations
Your UETDRRC006 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UETDRRC006 free