UETDRRC005 — Maintain, test and verify power systems in a very remote community
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UETDRRC005 must cover
56 assessable components: 4 elements (40 performance criteria), 11 performance evidence and 5 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to maintain, test and verify power systems
- 1.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are referred to and confirmed
- 1.2Work plan is obtained and confirmed in accordance with workplace requirements
- 1.3Materials required for work are identified and obtained in accordance with work plan and workplace requirements
- 1.4Work is prioritised and sequenced for completion in accordance with workplace requirements
- 1.5Hazards are identified, risks assessed and control measures identified and applied
- 1.6Work permits are received and signed in accordance with workplace requirements
- 1.7Switching/isolation schedule is developed in accordance with work plan and workplace requirements
- 1.8Plant, tools, equipment and PPE required for work are determined, obtained and confirmed in working order
- 1.9Specialist test equipment is obtained, confirmed in working order and calibrated in accordance with workplace requirements
- 1.10Worksite is prepared in accordance with work plan and workplace requirements
2 Carry out maintenance, testing and verification of generation power systems
- 2.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are applied and monitored
- 2.2Lifting, climbing, working at heights and the use of plant, tools, equipment and PPE are carried out in accordance with workplace requirements
- 2.3Hazard control measures are monitored in accordance with workplace requirements
- 2.4Generation power system switching/isolation authorisation is obtained in accordance with switching/isolation schedule and workplace requirements
- 2.5Generation power systems are isolated, proved de-energised and earthed in accordance with switching/isolation schedule and workplace requirements
- 2.6Generation power systems equipment and associated hardware is maintained in accordance with work plan and workplace requirements
- 2.7Generation power systems equipment and associated hardware are visually inspected to confirm compliance in accordance with work plan and workplace requirements
- 2.8Generation power system authorisation is obtained to commence restoration in accordance with switching/isolation schedule and workplace requirements
- 2.9Generation power systems are tested and verified compliant in accordance with work plan, work permits and workplace requirements
- 2.10Incidents or unplanned events are responded to in accordance with workplace requirements
- 2.11Quality checks of work are undertaken in accordance with work plan and workplace requirements
3 Solve electrical network apparatus and network circuit problems
- 3.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are applied and monitored
- 3.2Lifting, climbing, working at heights and the use of plant, tools, equipment and PPE are carried out in accordance with workplace requirements
- 3.3Hazard control measures are monitored in accordance with workplace requirements
- 3.4Live testing or measuring requirements are determined in accordance with workplace requirements
- 3.5Electrical network apparatus and network circuits are confirmed as isolated and earthed/short circuited in accordance with workplace requirements
- 3.6Operating parameters of the circuit within the electrical network apparatus are verified in accordance with workplace requirements
- 3.7Operating parameters of the network electrical circuits are verified in accordance with workplace requirements
- 3.8Established methodical processes are used to identify electrical problems from measured and calculated values in accordance with workplace requirements
- 3.9Electrical network apparatus circuit problems are solved without damage to apparatus or circuits to comply with workplace requirements
- 3.10Electrical network circuit problems are solved without damage to apparatus or circuits to comply with workplace requirements
- 3.11Earthing/short circuiting equipment is removed, permit signed off and electrical network apparatus and network circuits re-energised in accordance with workplace requirements
- 3.12Electrical network apparatus and network circuits are tested to determine correct operation in accordance with workplace requirements
- 3.13Incidents or unplanned events are responded to in accordance with workplace requirements
4 Complete work and documentation
- 4.1Completed work is checked for compliance against the work plan and workplace requirements
- 4.2Incidents or unplanned events are reported in accordance with workplace requirements
- 4.3Worksite is rehabilitated, cleaned and made safe in accordance with workplace requirements
- 4.4Plant, tools and equipment are cleaned, checked and returned to storage in accordance with workplace requirements
- 4.5Surplus materials are returned to storage or disposed of in accordance with workplace requirements
- 4.6Work records, reports and documentation are completed, and appropriate personnel notified in accordance with workplace requirements
Performance evidence
- applying relevant legislation, regulations, standards, codes of practice and organisational workplace requirements, including: - work health and safety (WHS)/occupational health and safety (OHS) - identifying hazards, assessing risks, identifying, applying and monitoring control measures - obtaining, inspecting and using relevant personal protective equipment (PPE) - preparing, issuing and signing on and off relevant work permits in accordance with workplace requirements
- isolating and restoring generation power systems, including: - identifying isolation points - preparing a generation isolation and restoration permit to work schedule - obtaining authorisation to isolate and restore generation power systems - isolating and restoring generation power systems in accordance with switching/isolation schedule
- maintaining generation power system, including: - conducting routine safety inspections - inspecting generation power system facilities - carrying out scheduled generator engine service - checking generation power system fuel facilities - conducting generation power station operational readings
- testing and maintaining generation power systems, including: - electrical equipment and switchgear - electrical earthing systems - identifying non-compliance - rectifying non-compliance or defects - completing testing documentation
- confirming network apparatus and network electrical circuits are isolated
- determining the operating parameters of a circuit within the electrical network apparatus
- using established methodical processes to solve electrical problems in accordance with workplace requirements, including: - choosing correct instruments and ranges for testing and measuring values - connecting instruments to measure and calculate values in electrical network apparatus and network circuits - identifying electrical network apparatus and network circuits problems, including at least three (3) of the following: - high (HV)/low voltage (LV) - high resistance - low resistance - fault current (fuses) - kilowatt hour meter faults (no supply, reverse polarity etc) - public lighting faults - working from at least one (1) of the following: - elevated work platform (EWP) - platform - ladder
- connecting and testing electrical network apparatus and network circuits to determine correct operation
- removing earthing/short circuiting equipment and re-energising electrical network apparatus and network circuits in accordance with workplace requirements
- dealing with an unplanned event on at least one (1) occasion
- completing relevant work records, reports and documentation
Knowledge evidence
- legislation, regulations, standards, codes of practice and organisational workplace requirements, including: - WHS/OHS - environmental - wiring rules requirements – continuity test and insulation resistance test - hazard, risk assessment and risk control requirements, including potential hazards - types and application of PPE - safe use of plant, tools and equipment - types, purpose and application of work permits - organisational workplace requirements, including: - generation power systems - electrical safety - isolation and restoration switching schedules
- generation power systems, including: - balance of plant - piping and instrument diagrams - control and switch rooms - electrical switchgear - electrical protection
- generation power system isolation and restoration, including: - generation permit to work - lock out, tag out (LOTO) - authorisations
- generation power system testing, including: - electricity network voltages - commissioning - safe use, care and storage of electrical instruments - fault loop impedance, including: - term fault loop impedance of an alternating current (a.c.) power system - measuring fault loop impedance of typical circuits - procedures for testing fault loop impedance - single phase systems - multi-phase systems - impedance in a.c. circuits
- documentation and reports, including: - work records - tests and commissions - incidents and unplanned events - periodic inspections - non-compliance and defects - events constituting an unplanned event or incident - procedures for responding to an unplanned event or incident
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UETDRRC005
What does an assessment tool for UETDRRC005 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UETDRRC005 needs to address all 56 unit components: 4 elements with 40 performance criteria, 11 performance evidence requirements, 5 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UETDRRC005?
Auditori pulls the current release of UETDRRC005 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UETDRRC005 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UETDRRC005 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UETDRRC005, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UETDRRC001 — Install and maintain low voltage overhead services in a very remote community
- UETDRRC002 — Install and maintain low voltage underground services in a very remote community
- UETDRRC003 — Install and maintain public lighting systems in a very remote community
- UETDRRC004 — Install and replace energy meters and associated equipment in a very remote community
- UETDRRC006 — Perform low voltage electricity network switching in a very remote community
- UETDRRC007 — Solve problems in electrical network apparatus in a very remote community
- UETDRRC008 — Solve problems in low voltage electrical network circuits in a very remote community
- UETDRRT001 — Install overhead rail traction configurations
- UETDRRT002 — Install overhead traction components and equipment
- UETDRRT003 — Install rail traction bonds
- UETDRRT004 — Install traction overhead wiring systems
- UETDRRT008 — Maintain overhead rail traction configurations
Your UETDRRC005 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UETDRRC005 free