UETDRRC004 — Install and replace energy meters and associated equipment in a very remote community
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UETDRRC004 must cover
45 assessable components: 3 elements (24 performance criteria), 8 performance evidence and 13 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to install and replace energy meters and associated equipment
- 1.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are referred to and confirmed
- 1.2Work plan is obtained and confirmed in accordance with workplace requirements
- 1.3Materials required for work are determined and obtained in accordance with work plan and workplace requirements
- 1.4Plant, tools, equipment and personal protective equipment (PPE) required for work are determined, obtained and confirmed in working order
- 1.5Hazards are identified, risks assessed and control measures identified and applied
- 1.6Work is prioritised and sequenced for completion in accordance with workplace requirements
- 1.7Electrical network circuit is confirmed as being isolated and earthed/short circuited in accordance with workplace requirements
- 1.8Work permits are received and signed in accordance with workplace requirements
- 1.9Worksite is prepared in accordance with work plan and workplace requirements
2 Carry out the installation or replacement of energy meters and associated equipment
- 2.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are applied and monitored
- 2.2Lifting, climbing, working at heights, the use of plant, tools, equipment and PPE are carried out in accordance with workplace requirements
- 2.3Hazard control measures are monitored in accordance with workplace requirements
- 2.4Installation or replacement of whole current energy meters is carried out in accordance with workplace requirements
- 2.5Earthing/short circuiting equipment is removed, permit signed off and electrical network circuits re-energised in accordance with workplace requirements
- 2.6Whole current energy meters and associated equipment are tested in accordance with workplace requirements
- 2.7Whole current energy meters and associated equipment are programmed and sealed in accordance with workplace requirements
- 2.8Incidents or unplanned events are responded to in accordance with workplace requirements
- 2.9Quality checks of work are undertaken in accordance with work plan and workplace requirements
3 Complete work and documentation
- 3.1Completed work is checked for compliance against the work plan and workplace requirements
- 3.2Incidents or unplanned events are reported in accordance with workplace requirements
- 3.3Worksite is rehabilitated, cleaned and made safe in accordance with workplace requirements
- 3.4Plant, tools and equipment are cleaned, checked and returned to storage in accordance with workplace requirements
- 3.5Surplus materials are returned to storage or disposed of in accordance with workplace requirements
- 3.6Work records, reports and documentation are completed, and appropriate personnel notified in accordance with workplace requirements
Performance evidence
- applying relevant legislation, regulations, standards, codes of practice and organisational workplace requirements, including: work health and safety (WHS)/occupational health and safety (OHS), identifying hazards, assessing risks, identifying, applying and monitoring control measures, obtaining, inspecting and using relevant personal protective equipment (PPE), preparing to enter the workplace including the use of work permits, clearances and isolation permissions, confirming electrical network circuits have been isolated and earthed/short circuited in accordance with work plan and workplace requirements
- installing or replacing at least one (1) of the following whole current energy meters: induction disk energy meter, electronic energy meter, electronic summator
- installing at least two (2) of the following associated metering equipment: service fuses, service links, meter panels, controlled output meters
- re-energising electrical network circuits in accordance with workplace requirements
- completing at least three (3) of the following tests of whole current energy meters: polarity* (must do), continuity, insulation resistance, meter functionality (load), neutral integrity, phase sequence (rotation), voltage
- working from at least one (1) of the following: elevated work platform (EWP), platform, ladder
- dealing with an unplanned event on at least one (1) occasion
- completing relevant work records, reporting and documentation
Knowledge evidence
- legislation, regulations, standards, codes of practice and organisational workplace requirements, including: WHS/OHS, hazard, risk assessment and risk control requirements, including potential hazards, types and application of PPE, safe use of plant, tools and equipment, application, purpose and types of permits
- whole current energy meters, including: construction, operation, error codes
- associated metering equipment, including: construction, operation
- metering arrangements, including: direct, distributed master, multiple master, plug-in, multiple earth neutral (MEN) system
- cable types and applications
- installation tools, equipment and testing devices
- installation and removal of energy meters, including: stripping cable, cable terminations, meter wiring positions, service protection device (SPD), meter boards
- testing procedures, including: continuity, insulation resistance, polarity, phase sequence, neutral integrity, meter functionality
- procedures for recording energy meter documentation
- customer education on energy meters
- techniques for the maintenance of energy metering, including: fault finding, fault rectification, meter reading, tariff changes
- events constituting an unplanned event or incident
- procedures for responding to an unplanned event or incident
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UETDRRC004
What does an assessment tool for UETDRRC004 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UETDRRC004 needs to address all 45 unit components: 3 elements with 24 performance criteria, 8 performance evidence requirements, 13 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UETDRRC004?
Auditori pulls the current release of UETDRRC004 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UETDRRC004 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UETDRRC004 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UETDRRC004, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UETDRRC001 — Install and maintain low voltage overhead services in a very remote community
- UETDRRC002 — Install and maintain low voltage underground services in a very remote community
- UETDRRC003 — Install and maintain public lighting systems in a very remote community
- UETDRRC005 — Maintain, test and verify power systems in a very remote community
- UETDRRC006 — Perform low voltage electricity network switching in a very remote community
- UETDRRC007 — Solve problems in electrical network apparatus in a very remote community
- UETDRRC008 — Solve problems in low voltage electrical network circuits in a very remote community
- UETDRRT001 — Install overhead rail traction configurations
- UETDRRT002 — Install overhead traction components and equipment
- UETDRRT003 — Install rail traction bonds
- UETDRRT004 — Install traction overhead wiring systems
- UETDRRT008 — Maintain overhead rail traction configurations
Your UETDRRC004 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UETDRRC004 free