UETDRRC001 — Install and maintain low voltage overhead services in a very remote community
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UETDRRC001 must cover
42 assessable components: 3 elements (24 performance criteria), 8 performance evidence and 10 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to install and maintain LV overhead services
- 1.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are referred to and confirmed
- 1.2Work plan is obtained and confirmed in accordance with workplace requirements
- 1.3Materials required for work are determined and obtained in accordance with work plan and workplace requirements
- 1.4Hazards are identified, risks assessed and control measures identified and applied
- 1.5Work permits are received and signed in accordance with workplace requirements
- 1.6Plant, tools, equipment and personal protective equipment (PPE) required for work are determined, obtained and confirmed in working order
- 1.7Overhead electrical distribution network is verified as isolated and earthed/short circuited in accordance with workplace requirements
- 1.8Work is prioritised and sequenced for completion in accordance with workplace requirements
- 1.9Worksite is prepared in accordance with work plan and workplace requirements
- 1.10Traffic management plan is confirmed as being in place in accordance with workplace requirements
2 Carry out installation and maintenance of LV overhead services
- 2.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are applied and monitored
- 2.2Lifting, climbing, working at heights and the use of plant, tools, equipment and PPE are carried out in accordance with workplace requirements
- 2.3Hazard control measures are monitored in accordance with workplace requirements
- 2.4Installation and maintenance of the LV overhead service is completed in accordance with work plan and workplace requirements
- 2.5Earthing and short circuiting equipment is removed, permit signed off and overhead electrical distribution network is re-energised in accordance with workplace requirements
- 2.6LV overhead service connections are tested in accordance with work plan and workplace requirements
- 2.7Incidents or unplanned events are responded to in accordance with workplace requirements
- 2.8Quality checks of work are undertaken in accordance with work plan and workplace requirements
3 Complete work and documentation
- 3.1Completed work is checked for compliance against the work plan and workplace requirements
- 3.2Incidents or unplanned events are reported in accordance with workplace requirements
- 3.3Worksite is rehabilitated, cleaned and made safe in accordance with workplace requirements
- 3.4Plant, tools and equipment are cleaned, checked and returned to storage in accordance with workplace requirements
- 3.5Surplus materials are returned to storage or disposed of in accordance with workplace requirements
- 3.6Work records, reports and documentation are completed, and appropriate personnel notified in accordance with workplace requirements
Performance evidence
- applying relevant legislation, regulations, standards, codes of practice and organisational workplace requirements, including: - work health and safety (WHS)/occupational health and safety (OHS) - identifying hazards, assessing risks, identifying, applying and monitoring control measures - obtaining, inspecting and using relevant personal protective equipment (PPE) - obtaining and signing on and off relevant work permits in accordance with workplace requirements - verifying power systems electrical distribution network has been isolated and earthed and short circuited in accordance with work plan and workplace requirements
- connecting low voltage (LV) overhead service cables, including at least two (2) of the following: - three phase * - single phase - two phase - (* must do)
- installing LV overhead service protection devices, including at least one (1) of the following: - service fuse - circuit breakers (pole) - service link
- testing LV overhead service cable connections, including all the following: - polarity test - phase rotation test - continuity test - voltage test - neutral loop impedance - insulation resistance
- restoring supply to LV electricity networks in accordance with work plan and workplace requirements
- working from at least one (1) of the following: - elevated work platform (EWP) - platform - ladder
- dealing with an unplanned event on at least one (1) occasion
- completing relevant work records, reports and documentation
Knowledge evidence
- legislation, regulations, standards, codes of practice and organisational workplace requirements, including: - WHS/OHS - hazard, risk assessment and risk control requirements, including potential hazards - types and application of PPE - safe use of plant, tools and equipment - application, purpose and types of permits
- types and characteristics of LV overhead service equipment, including: - connectors - insulation piercing connectors (IPCs) - service termination devices - fuse holders - fuses - service poles - point-of-attachment brackets - mains connection boxes - construction manuals, system diagrams, plans and drawings
- types, sizes and characteristics of LV overhead service cables, including: - two, three and four-core cable - cable cross-sectional area of conductors - current ratings - cable insulation materials
- types of installation plant, equipment and tools, including: - EWPs - ladders - service cable puller and tension tool - stripping tools - ABC spanner and spreader
- installation techniques, including: - consumer poles - location of attachments - methods of stringing, tensioning and terminating - minimum clearances to assets, structures and the ground - maximum span lengths and service cable tensions
- connection principles, including: - relevant electrical access permit - purpose and function of the multiple earth neutral (MEN) system - types of connection faults - causes and effects of incorrect and poor electrical connections - principles of loop impedance - reasons for and methods used to maintain standard phase sequencing - purpose and operation of service fusing
- testing and commissioning procedures, including: - inspection - equipment functionality - use of independent earth for testing: - continuity - insulation testing - polarity, voltage and phase sequence - neutral integrity - meter function - connection testing forms and documentation
- techniques for maintenance of overhead services, including: - inspection - types of faults - diagnosis and repair of faults - removing and replacing services and fuses
- events constituting an unplanned event or incident
- procedures for responding to an unplanned event or incident
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UETDRRC001
What does an assessment tool for UETDRRC001 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UETDRRC001 needs to address all 42 unit components: 3 elements with 24 performance criteria, 8 performance evidence requirements, 10 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UETDRRC001?
Auditori pulls the current release of UETDRRC001 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UETDRRC001 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UETDRRC001 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UETDRRC001, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UETDRRC002 — Install and maintain low voltage underground services in a very remote community
- UETDRRC003 — Install and maintain public lighting systems in a very remote community
- UETDRRC004 — Install and replace energy meters and associated equipment in a very remote community
- UETDRRC005 — Maintain, test and verify power systems in a very remote community
- UETDRRC006 — Perform low voltage electricity network switching in a very remote community
- UETDRRC007 — Solve problems in electrical network apparatus in a very remote community
- UETDRRC008 — Solve problems in low voltage electrical network circuits in a very remote community
- UETDRRT001 — Install overhead rail traction configurations
- UETDRRT002 — Install overhead traction components and equipment
- UETDRRT003 — Install rail traction bonds
- UETDRRT004 — Install traction overhead wiring systems
- UETDRRT008 — Maintain overhead rail traction configurations