What an assessment for UETDRIS011 must cover
88 assessable components: 3 elements (25 performance criteria), 24 performance evidence and 39 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to install and maintain LV underground services
- 1.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are referred to and confirmed
- 1.2Work plan is obtained and confirmed in accordance with workplace requirements
- 1.3Materials required for work are determined and obtained in accordance with work plan and workplace requirements
- 1.4Work is prioritised and sequenced for completion in accordance with work plan and workplace requirements
- 1.5Hazards are identified, risks assessed and control measures identified and applied
- 1.6Plant, tools, equipment and personal protective equipment (PPE) required for work are determined, obtained and confirmed in working order
- 1.7Worksite is prepared in accordance with the work plan and workplace requirements
- 1.8Traffic management plan is confirmed as being in place in accordance with workplace requirements
- 1.9Safety observer role and responsibilities are discussed and confirmed in accordance with workplace requirements
- 1.10Communication method between the workers and safety observer is determined and confirmed in accordance with workplace requirements
2 Carry out installation and maintenance of LV underground services
- 2.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are applied and monitored
- 2.2Lifting, working at heights and the use of plant, tools, equipment and PPE are carried out in accordance with workplace requirements
- 2.3Hazard control measures are monitored in accordance with workplace requirements
- 2.4Safety observer is positioned to observe the work in accordance with workplace requirements
- 2.5Communication methods between workers and safety observer are used in accordance with workplace requirements
- 2.6LV underground service and hardware are installed in accordance with the work plan and workplace requirements
- 2.7LV underground service and hardware are maintained in accordance with the work plan and workplace requirements
- 2.8Incidents or unplanned events are responded to in accordance with workplace requirements
- 2.9Quality checks of work are undertaken in accordance with work plan and workplace requirements
3 Complete work and documentation
- 3.1Completed work is checked for compliance against the work plan and workplace requirements
- 3.2Incidents or unplanned events are reported in accordance with workplace requirements
- 3.3Worksite is rehabilitated, cleaned and made safe in accordance with workplace requirements
- 3.4Plant, tools and equipment are cleaned, checked and returned to storage in accordance with workplace requirements
- 3.5Surplus materials are returned to storage or disposed of in accordance with workplace requirements
- 3.6Work records, reports and documentation are completed in accordance with workplace requirements
Performance evidence
- applying relevant legislation, regulations, standards, codes of practice and organisational workplace requirements, including:
- work health and safety (WHS)/occupational health and safety (OHS)
- identifying hazards, assessing risks, identifying, applying and monitoring control measures
- obtaining, inspecting and using relevant personal protective equipment (PPE)
- determining communication method with safety observer
- confirming safety observer is in position in accordance with workplace requirements
- applying energised/live low voltage (LV) working requirements and procedures in accordance with workplace requirements
- connecting LV underground services to at least two (2) of the following:
- underground pillar/pit connection (single phase)
- underground pillar/pit connection (three phase)
- underground to overhead connection
- using the following specialised energised LV equipment:
- insulating mats/covers
- insulating gloves
- testing of LV underground service connections, including at least four (4) of the following tests:
- polarity*
- neutral integrity*
- phase rotation
- continuity
- voltage
- insulation resistance
- (* must do)
- dealing with an unplanned event on at least one (1) occasion
- completing relevant work records, reports and documentation
Knowledge evidence
- relevant legislation, regulations, standards, codes of practice and organisational workplace requirements, including:
- WHS/OHS
- hazard, risk assessment and risk control requirements, including potential hazards
- types and application of PPE
- safe use of plant, tools and equipment
- safety observer:
- role and responsibilities
- communication methods
- events constituting an unplanned event or incident
- procedures for responding to an unplanned event or incident
- requirements for the use of workplace construction manuals, system diagrams/plans and drawings, including:
- types of LV underground services
- methods of construction and installation
- minimum depths for underground services to be buried and proximity to other assets and structures
- materials for underground service installation
- methods of laying underground service cables
- characteristics and applications of different types of cables
- diagnosis and repair of faults
- jointing and terminating methods in a:
- fuse box
- pillar and pit
- customer installation
- testing and commissioning underground services, including:
- pre-energising tests - insulation resistance and continuity test
- inspection
- test equipment functionality and interpretation
- polarity, voltage and phase sequence tests
- neutral and phase identification tests
- neutral integrity tests
- recording results
- connection principles, including:
- energised/live work requirements and procedures
- purpose and function of multiple earth neutral (MEN) system
- types of connection faults
- causes and effects of incorrect and poor electrical connections
- principles of loop impedance
- reasons for and methods used to maintain standard phase sequencing
- purpose and operation of service fusing
- use of independent earth for testing
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UETDRIS011
What does an assessment tool for UETDRIS011 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UETDRIS011 needs to address all 88 unit components: 3 elements with 25 performance criteria, 24 performance evidence requirements, 39 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UETDRIS011?
Auditori pulls the current release of UETDRIS011 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UETDRIS011 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UETDRIS011 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UETDRIS011, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UETDRIS007 — Install and maintain distribution overhead conductors and cables
- UETDRIS008 — Install and maintain electrical apparatus
- UETDRIS010 — Install and maintain low voltage overhead services
- UETDRIS012 — Install and maintain poles, structures and hardware
- UETDRIS013 — Install and maintain public lighting systems
- UETDRIS014 — Install and replace energy meters and associated equipment
- UETDRIS015 — Install low voltage mobile generator
- UETDRIS017 — Perform high voltage field switching operation to a given schedule
- UETDRIS018 — Perform low voltage field switching operation to a given schedule
- UETDRIS020 — Contribute to coordinated high voltage live work
- UETDRIS021 — Coordinate and direct switching programs
- UETDRIS022 — Coordinate permit procedures
Your UETDRIS011 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UETDRIS011 free