ICTCBL247Install, maintain and modify customer premises communications cabling: ACMA Open Rule

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for ICTCBL247 must cover

88 assessable components: 10 elements (45 performance criteria), 19 performance evidence and 18 knowledge evidence requirements, plus 6 foundation skills. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Plan open cabling work

  • 1.1Identify building infrastructure that places critical constraints on cabling
  • 1.2Apply organisational strategies to manage other infrastructure in relation to cabling
  • 1.3Notify appropriate personnel of identified safety hazards at cabling worksite

2 Manage remote power feed

  • 2.1Identify and avoid risks posed by contact with remote power feeding services when performing cabling activity
  • 2.2Make site safe by identifying remote power feeding services that operate at above telecommunications network voltage (TNV) inside customer premises

3 Install and modify cable support, earthing and termination infrastructure

  • 3.1Install fixings and cable support structures of adequate strength, safely and aligned with the environment according to manufacturer and customer specifications
  • 3.2Secure catenary supports to building structure and tension, as required, to ensure cable weight can be carried in operating conditions with interference and safety segregation maintained according to current Australian Standards
  • 3.3Install protective earthing of metal work to industry standards, as required
  • 3.4Inspect installed support structure to ensure cable will not be exposed to damage during installation and general operation
  • 3.5Position terminating equipment and fixing according to industry codes of practice, standards and customer requirements
  • 3.6Inspect back-mount and outlet layout for compliance to manufacturer specifications, and allow adequate work space for ease of access and avoid overlaying
  • 3.7Segregate incoming and outgoing cables for ease of access and avoid overlaying

4 Install cables and earth wires

  • 4.1Install cables according to manufacturer specifications, including tension and bending stress requirements
  • 4.2Identify and avoid sources of possible damage to cable, including hot pipes, sharp edges, cable burn, kinks, crushing or stretching
  • 4.3Allow sufficient excess at cable ends to facilitate termination
  • 4.4Label telecommunication outlet ends of cable uniquely to match identifier at originating location
  • 4.5Place and secure cable to maintain safety and interference segregation according to legislative and industry standards
  • 4.6Install cable fasteners with correct tension, and trim or fit them flush to prevent cable sheath damage, transmission impairment or risk of personal damage
  • 4.7Use appropriate aerial cable installation techniques associated with supported catenaries in external environment to meet minimum above ground clearances and segregation from hazardous electrical services, according to current Australian Standards
  • 4.8Use appropriate underground cable installation techniques associated with minimum depth of cover and segregation from hazardous electrical and other services, according to current Australian Standards
  • 4.9Identify issues surrounding underground cables (excluding blown fibre tube systems) to incorporate a blocking agent within the cable to prevent the ingress of water
  • 4.10Install over-voltage protection devices to all cable pairs according to current Australian Standards, as required, to suppress voltage surges with the over-voltage devices connected to protective earth
  • 4.11Conduct a visual inspection to verify telecommunications reference conductor (TRC) / communications earthing system (CES)/earth wire insulation is protected against damage and is segregated according to relevant industry, legislative and Australian Standards

5 Terminate and test cables and earth wires

  • 5.1Remove cable sheath to allow for correct termination length without damage to underlying conductors and their insulation
  • 5.2Install terminating modules to different telecommunications cables according to manufacturer specifications, and cable pairs neatly and sequentially fan for termination
  • 5.3Terminate conductors according to recommended colour code sequence using appropriate termination tools according to manufacturer specifications
  • 5.4Earth cable shield, as required, according to manufacturer specifications, relevant industry codes of practice and current Australian Standards
  • 5.5Conduct visual inspection to confirm termination colour code sequence has been followed prior to end-to-end testing of wire and pair termination integrity
  • 5.6Terminate earth wires with connectors recommended by manufacturer according to industry codes of practice and current Australian Standards
  • 5.7Ensure earth wire continuity throughout and observe interface requirements with electrical systems
  • 5.8Test earthing installation for continuity and conductive resistance according to industry standards
  • 5.9Confirm compatibility of alterations with existing systems and test new work both in isolation and when integrated with existing systems
  • 5.10Conduct testing of installed cable continuity after termination

6 Inspect cable route to ensure correct separations

  • 6.1Inspect separations along the entirety of the cable route and rectify separations that do not comply with regulations
  • 6.2Install barriers to achieve separations where sufficient spatial separation cannot be met

7 Evaluate earthing needs for cable systems on customer premises

  • 7.1Locate existing earthing systems in customer premises and analyse earthing needs of cable products
  • 7.2Calculate upper and lower limits of resistance for a variety of cable system earths using relevant cable characteristics

8 Label earthing systems

  • 8.1Identify label requirements for telecommunications earthing systems
  • 8.2Attach label to earthing systems according to industry regulations

9 Create or update cable plans and records

  • 9.1Document installation details on record sheets and plans, and store according to customer requirements
  • 9.2Label cable pairs clearly as required to provide an accurate identification according to manufacturer specifications, industry standards and customer requirements
  • 9.3Record cabling details in cable pair record books to provide an accurate record, according to industry codes of practice and current Australian Standards
  • 9.4Complete telecommunications cabling advice (TCA) forms

10 Monitor work activity

  • 10.1Supervise unregistered cablers undertaking work in line with scope of own role and organisational procedures
  • 10.2Ensure installation and maintenance activity comply with legislative requirements and industry standards for safety and network integrity

Performance evidence

  • complete a cabling installation and termination for: three different types of telephone sockets: Australian modular socket, RJ45, RJ12 or RJ11 modular socket, Mode 3 alarm socket; one network termination device (NTD), including the completion of TCA1 compliance forms and NTD records
  • read and interpret drawings related to cable layouts, outlet location, cable coding system, and identifiers and distributor locations
  • comply with all work, health and safety (WHS) requirements and work practices
  • meet Australian Communications and Media Authority (ACMA) requirements
  • apply cable conductor identification codes to connector pins
  • conduct tests and interpret cable test results
  • identify the correct telecommunications cable by its colour identifier
  • terminate systems at both distributor and outlet locations
  • install and terminate two jumperable distributors (campus distributor or building distributor) with a capacity of 100 pair or greater
  • terminate one non-jumperable distributor (local distributor)
  • terminate both cable ends for at least one 50 pair cable, 10 or 20 pair cable and one 4 pair data cable, including accurate completion of installation records, drawing alterations and compliance forms
  • place cables on support structures and building faces for both internal and external locations
  • secure cables with appropriate fasteners for the above locations
  • apply work practices that avoid cable damage
  • install at least one common type of earthing system used in customer premises for cabling systems
  • interpret and apply relevant legislation, regulations, codes, and standards
  • install earthing to suit cabling conditions
  • identify and rectify faulty cabling
  • use appropriate personal protective equipment when performing cabling tasks

Knowledge evidence

  • legislation, regulations, codes, standards, rules, guidance notes and other formal agreements that impact on work, in particular: Australian Communications and Media Authority (ACMA) Telecommunications Cabling Provider Rules, cabling registrars, cabler registration rules, regulations and standards; current Communications Alliance Standards including AS/CA S009 Installation requirements for customer cabling (Wiring Rules); national and state/territory WHS requirements; workplace and worksite requirements; cabling environment, cable type, cable identification, termination systems, earthing and protection, records; ACMA certified components list; labelling requirements
  • basic electrical principles of: insulation, resistance; capacitance; impedance – as causes of, impedance, attenuation and cross-talk; cable screening types; colour codes; cable conductor – types of codes
  • customer switching systems and services
  • printed circuit boards
  • customer cabling environment for which cabling registration may be required for internal, external, above ground or below ground installation
  • information required to operate equipment according to a test specification
  • various cable types, their identifiers, termination systems (including jumperable and non-jumperable distributor), separations, support systems and fastening techniques used for telecommunications cabling
  • documentation and records required when cabling
  • manufacturer requirements for safe operation of equipment
  • earthing and protection strategies and technologies relevant to different cabling applications
  • test methods and performance requirements
  • typical issues and challenges that occur on site
  • installation requirements for underground and aerial cables including: minimum depth of cover (below ground); segregation from hazardous electrical and other services; earthing requirements; design parameters for underground cables with regards to the purpose they will serve and the prevention of water ingress
  • devices for a range of telecommunications cabling applications, including, ethernet data systems, audio and video systems, security systems and fire protection systems
  • integral bearer wires and application according to current Australian Standards
  • cable blocking agents used to prevent the ingress of water underground (excluding blown fibre tube systems)
  • features of cables designed for underground use that may be laid in conduit trenches or directly buried
  • responsibilities and process for communications installation works

Foundation skills

  • Reading: Recognises the structures and distinguishing features of a range of familiar text types
  • Writing: Sequences writing to produce cohesive text and uses layout consistent with text type
  • Oral Communication: Demonstrates awareness of choices for register, especially in situations that are familiar
  • Numeracy: Interprets and comprehends whole and familiar or routine fractions, decimals and percentages when measuring and preparing cables for installation
  • Navigate the world of work: Takes personal responsibility for adherence to legal/regulatory responsibilities relevant to own work context, and draws attention to any issues that may affect self or others
  • Get the work done: Implements actions as per plan, making slight adjustments if necessary, and addressing some unexpected issues. Automatically implements standard procedures for routine decisions in response to familiar problems

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing ICTCBL247

What does an assessment tool for ICTCBL247 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for ICTCBL247 needs to address all 88 unit components: 10 elements with 45 performance criteria, 19 performance evidence requirements, 18 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for ICTCBL247?

Auditori pulls the current release of ICTCBL247 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for ICTCBL247 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing ICTCBL247 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of ICTCBL247, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your ICTCBL247 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate ICTCBL247 free