ICTCBL246Install, maintain and modify customer premises communications cabling: ACMA Restricted Rule

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for ICTCBL246 must cover

77 assessable components: 7 elements (30 performance criteria), 14 performance evidence and 27 knowledge evidence requirements, plus 6 foundation skills. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Plan restricted cabling work

  • 1.1Identify building infrastructure that places critical constraints on cabling
  • 1.2Apply organisational strategies to manage other infrastructure in relation to cabling
  • 1.3Notify appropriate personnel of identified safety hazards at cabling work site

2 Manage remote power feed

  • 2.1Identify and avoid risks posed by contact with remote power feeding services when performing cabling activity
  • 2.2Make site safe by identifying remote power feeding services that operate at above telecommunications network voltage (TNV) inside customer premises

3 Install cables and protective earth wires

  • 3.1Install cables according to manufacturer application specifications, including tension and bending stress requirements
  • 3.2Identify and avoid sources of possible damage to cable, including hot pipes, sharp edges and cable burn
  • 3.3Allow sufficient excess at cable ends to facilitate termination
  • 3.4Place and secure cable to maintain safety and interference segregation according to legislative and industry standards
  • 3.5Install cable fasteners with correct tension to prevent cable sheath damage or transmission impairment and trimmed flush to prevent risk of personal damage
  • 3.6Use appropriate underground cable installation techniques associated with minimum depth of cover and segregation from hazardous electrical and other services according to current Australian Standards
  • 3.7Identify issues surrounding underground cables (excluding blown fibre tube systems) to incorporate a blocking agent within the cable to prevent the ingress of water
  • 3.8Use appropriate aerial cable installation techniques associated with minimum clearance, segregation from hazardous electrical and other services and minimum height requirements according to current Australian Standards
  • 3.9Install over-voltage protection devices to all cable pairs according to Australian Standards, as required, to suppress voltage surges and protect from earth potential rise (EPR) hazards and protectively earth the devices
  • 3.10Protect earth wire insulation against damage and segregate protective earths according to relevant legislative and industry standards

4 Terminate and test cables and earth wires

  • 4.1Remove cable sheath to allow for correct termination length and without damage to underlying conductors and their insulation
  • 4.2Install cable modules according to manufacturer specifications, and cable pairs neatly and sequentially fan for termination
  • 4.3Terminate conductors according to recommended colour code sequence using appropriate termination tools according to manufacturer specifications
  • 4.4Earth cable shield, as required, according to manufacturer specifications, relevant industry codes of practice and Australian Standards
  • 4.5Conduct visual inspection to confirm termination colour code sequence has been followed prior to end-to-end testing of wire and pair termination integrity
  • 4.6Terminate earth wire according to industry codes of practice and Australian Standards
  • 4.7Ensure earth wire continuity throughout and observe interface requirements with electrical systems
  • 4.8Test earthing installation for continuity, insulation resistance and conductive resistance according to industry standards and Australian Standards
  • 4.9Confirm compatibility of alterations with existing systems and test new work both in isolation and when integrated with existing systems

5 Inspect cable route to ensure correct separations

  • 5.1Inspect separations along the entirety of the cable route and rectify separations that do not comply with regulations
  • 5.2Install barriers to achieve separations where sufficient spatial separation cannot be met

6 Create records

  • 6.1Provide customer with a job sign-off telecommunications cabling advice form at the completion of each cabling task
  • 6.2Complete NTD record cards for work undertaken

7 Monitor work activity

  • 7.1Supervise unregistered cablers undertaking work in line with scope of own role and organisational procedures
  • 7.2Ensure cabling activity is according to legislative requirements for safety and network integrity including the relevant Australian Standards

Performance evidence

  • complete a cabling installation and termination for:
  • three different types of telephone sockets:
  • Australian modular socket
  • RJ45, RJ12 or RJ11 modular socket
  • Mode 3 alarm socket
  • one network termination device (NTD), including the completion of TCA1 compliance forms and NTD records
  • apply cable conductor identification codes to connector pins
  • conduct tests and interpret cable test results
  • interpret and apply standards and regulations
  • comply with all related work health and safety (WHS) requirements and work practices
  • meet Australian Communications and Media Authority’s (ACMA) requirements
  • install earthing to suit cabling conditions
  • identify and rectify faulty cabling
  • use appropriate personal protective equipment when performing cabling tasks.

Knowledge evidence

  • legislation, regulations, codes, standards, rules, guidance notes and other formal agreements that impact on work, in particular:
  • Australian Communications and Media Authority (ACMA) Telecommunications Cabling Provider Rules, cabling registrars, cabler registration rules, regulations and standards
  • current Australian Standards including AS/CA S009:2013 Installation requirements for customer cabling (Wiring Rules)
  • national and state/territory WHS requirements
  • workplace and worksite requirements
  • cabling environment, cable type, cable identification, termination systems, earthing and protection, records
  • ACMA certified components list
  • labelling requirements
  • basic electrical principles of:
  • insulation, resistance
  • capacitance
  • impedance – as causes of, impedance, attenuation and cross-talk
  • cable conductor – types of codes
  • customer switching systems and services
  • printed circuit boards
  • cable screening types
  • colour codes
  • various cable types, their identifiers, termination systems, separations, support systems and fastening techniques used for communications cabling
  • features and operating requirements of recognised cabling specific industry test equipment
  • information required to operate equipment according to a test specification
  • manufacturer requirements for safe operation of equipment
  • test methods and performance requirements
  • installation requirements for underground and aerial cables including:
  • minimum depth of cover (below ground)
  • segregation from hazardous electrical and other services
  • earthing requirements
  • design parameters for underground cables with regards to the purpose they will serve and the prevention of water ingress.

Foundation skills

  • Reading: Recognises and responds to some conventions of complex texts Recognises when unknown words are essential to meaning and uses a range of decoding strategies to identify them
  • Writing: Uses a legible handwriting style or a computer font appropriate to the audience and purpose
  • Oral Communication: Demonstrates awareness of choices for register, especially in situations that are familiar
  • Numeracy: Relies substantially on hands-on (concrete) and real life materials, personal experience and prior knowledge to make estimations and check the reasonableness of processes Identifies appropriate tools and uses them to take measurements Interprets information based on results of technical tests
  • Navigate the world of work: Takes personal responsibility for adherence to legal/regulatory responsibilities relevant to own work context, and draws attention to any issues that may affect self or others
  • Get the work done: Implements actions as per plan, making slight adjustments if necessary, and addressing some unexpected issues Automatically implements standard procedures for routine decisions in response to familiar problems

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing ICTCBL246

What does an assessment tool for ICTCBL246 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for ICTCBL246 needs to address all 77 unit components: 7 elements with 30 performance criteria, 14 performance evidence requirements, 27 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for ICTCBL246?

Auditori pulls the current release of ICTCBL246 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for ICTCBL246 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing ICTCBL246 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of ICTCBL246, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your ICTCBL246 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate ICTCBL246 free