CPCCBL3012 — Construct fireplaces and chimneys
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for CPCCBL3012 must cover
53 assessable components: 8 elements (31 performance criteria), 3 performance evidence and 18 knowledge evidence requirements, plus 1 foundation skills. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare for work.
- 1.1Select, fit correctly and use personal protective equipment (PPE) appropriate for job.
- 1.2Read, interpret and apply fireplace and chimney construction requirements from current plans, specifications, standards and codes.
- 1.3Follow requirements in workplace safety and environmental documentation and workplace procedures.
- 1.4Use measurements and apply formulas to calculate material quantities.
- 1.5Identify potential hazards and determine and implement control measures.
- 1.6Select appropriate plant, equipment and tools, check condition and report damage or faults to relevant person.
- 1.7Check conformity of materials against the specifications and place materials in preparation for the work.
2 Set out and construct base and hearth.
- 2.1Locate and set out fireplace base to specified size.
- 2.2Mix mortar to quality and consistency specifications.
- 2.3Lay masonry base level, straight and plumb to the correct gauge and bond.
3 Construct firebox and inner hearth.
- 3.1Set out the first course for fire box and jambs to specified dimensions.
- 3.2Set out gathering/curve of fireback on floor.
- 3.3Construct firebox maintaining gauge, level and plumb to allowable tolerances.
- 3.4Form gather with corbelled brickwork to provide the specified throat size.
- 3.5Install the lintel at the specified height to meet bearing rules and maintain bond.
4 Form smoke shelf and throat.
- 4.1Form smoke shelf to the specified shape with mortar parging.
- 4.2Cover finished smoke shelf to protect from damage during construction.
- 4.3Check and alter throat size to meet the specified size.
5 Form smoke chamber.
- 5.1Lay gathering over/corbelling to specified angle and correct bond.
- 5.2Parge smoke chamber to minimum thickness to achieve a smooth mortar finish.
6 Construction flue.
- 6.1Lay gathering with directional change to break the light.
- 6.2Parge inside of flue.
7 Complete chimney stack.
- 7.1Install lead chimney tray at the specified height.
- 7.2Extend chimney square and plumb to finished height.
- 7.3Lay chimney capping or sand cement flaunching to prevent water intrusion.
- 7.4Finish joints to specified profile and depth.
- 7.5Clean excess mortar and brush down face work.
- 7.6Lay brickwork hearth and complete to meet Australian Standards.
8 Clean up.
- 8.1Clear the work area, and dispose of, reuse or recycle materials following workplace and environmental requirements.
- 8.2Clean tools and equipment, check for serviceability and report damage or faults
- 8.3Store and secure tools and equipment following workplace procedures.
Performance evidence
- install chimney flashing
- install weather proof chimney capping
- comply with fireplace and chimney standards and codes
Knowledge evidence
- terminology relating to fireplace and chimney construction
- current and relevant standards and building codes: minimum and maximum dimensions for components
- current and relevant standards and building codes: allowable tolerances
- current and relevant standards and building codes: flashing requirements
- current and relevant standards and building codes: key requirements of the National Construction Code (NCC) relevant to fireplaces and chimneys
- characteristics, applications and limitations of specified materials and products for fireplace and chimney construction: mortar specifications (M code)
- characteristics, applications and limitations of specified materials and products for fireplace and chimney construction: parging ingredients
- characteristics, applications and limitations of specified materials and products for fireplace and chimney construction: refractory bricks
- processes and techniques for fireplace and chimney construction: brick bond patterns
- processes and techniques for fireplace and chimney construction: roof flashing and weathering
- processes and techniques for fireplace and chimney construction: working drawing and specifications
- functional and operational features of plant, equipment and hand and power tools: power assisted tools
- workplace safety: erecting and dismantling work platforms
- workplace safety: working at heights
- workplace safety: job safety and environmental analysis (JSEA)
- workplace safety: exposure to silica
- workplace safety: exposure to loud noise
- environmental requirements for workplace processes and waste disposal
Foundation skills
- technology skills: use digital tools and devices to source job information and communicate effectively with others.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing CPCCBL3012
What does an assessment tool for CPCCBL3012 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for CPCCBL3012 needs to address all 53 unit components: 8 elements with 31 performance criteria, 3 performance evidence requirements, 18 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for CPCCBL3012?
Auditori pulls the current release of CPCCBL3012 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for CPCCBL3012 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing CPCCBL3012 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of CPCCBL3012, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- CPCCBL2001 — Handle and prepare bricklaying and blocklaying materials
- CPCCBL2002 — Use bricklaying and blocklaying tools and equipment
- CPCCBL3001 — Lay paving
- CPCCBL3002 — Carry out masonry veneer construction
- CPCCBL3003 — Carry out cavity brick construction
- CPCCBL3004 — Construct masonry steps and stairs
- CPCCBL3005 — Lay masonry walls and corners
- CPCCBL3006 — Lay multi-thickness walls and piers
- CPCCBL3007 — Install glass blockwork
- CPCCBL3009 — Install flashings and damp proof course
- CPCCBL3010 — Construct masonry arches
- CPCCBL3011 — Construct curved walls
Your CPCCBL3012 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate CPCCBL3012 free