CPCCRT3006 — Fix shingles to roofs and facades
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for CPCCRT3006 must cover
73 assessable components: 6 elements (29 performance criteria), 8 performance evidence and 36 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Plan and prepare to fix shingles to roofs and facades.
- 1.1Read and interpret work instructions and plan sequence of work.
- 1.2Plan all work to comply with laws and regulations, the National Construction Code (NCC), Australian Standards, work health and safety (WHS) and environmental requirements, manufacturers’ specifications and workplace requirements.
- 1.3Select and use personal protective equipment (PPE) for each stage of the task.
- 1.4Inspect work site, assess hazards and apply risk controls, including required signage and barricades.
- 1.5Select tools and equipment, check for serviceability and report any faults.
- 1.6Select materials required for task, calculate quantities, handle safely, and prepare and position ready for use.
2 Prepare roof face.
- 2.1Check that fall safety devices have been installed correctly.
- 2.2Handle, assemble and erect elevator at job location.
- 2.3Set out roof surface, board/batten, sark and strike.
- 2.4Check roof surface and structure for stability and for safe access to roof.
3 Install shingles/shakes.
- 3.1Load, support and distribute shingles/shakes evenly on roof.
- 3.2Lay sarking below initial course of shingles/shakes.
- 3.3Fix shingles/shakes in line, with spacing and guttering overhang.
- 3.4Lay subsequent courses with sarking and shingles.
- 3.5Maintain staggered joints and bonds with overlapping shingles/shakes.
- 3.6Split shingles/shakes and cut to form junctions with walls or roof surfaces.
- 3.7Finish valleys.
- 3.8Finish gable ends to line and overhang.
4 Finish hips and ridges.
- 4.1Select same-size shingles/shakes for hips and ridges.
- 4.2Bevel-cut edges of shingles/shakes to provide butt joints in capping sections.
- 4.3Cover, fix and finish hips and ridges to line.
5 Clad walls and facades.
- 5.1Select method of finishing shingles/shakes on wall or facade.
- 5.2Sheet and fix sheathed surfaces to framework.
- 5.3Set out wall or facade spacing for battens and exposure of shingles/shakes.
- 5.4Fit sarking and shingles/shakes.
- 5.5Construct junctions at corners to finishes.
- 5.6Finish flashings.
6 Clean up.
- 6.1Clear work area and dispose of materials, and reuse or recycle materials in accordance with legislation, regulations, codes of practice.
- 6.2Clean, check, maintain and store tools and equipment in accordance with manufacturers’ specifications.
Performance evidence
- fixing shingles and/or shakes to a roof frame, incorporating: setting out, boarding and/or battening, sarking and striking
- a 1.5 metre hip
- a 1.5 metre valley
- a 1.5 metre gable
- a 1.5 metre top ridge
- an external wall of minimum 1 square metre, incorporating: an internal corner with flashing
- sarking, battening and finishing
- All work must be performed to the standard required in the workplace and must comply with laws and regulations, the National Construction Code (NCC), Australian Standards, work health and safety (WHS) and environmental requirements, manufacturers’ specifications and workplace requirements.
Knowledge evidence
- compliance requirements of the NCC and Australian Standards for fixing shingles to roofs and facades
- workplace quality policies and standards for fixing shingles to roofs and facades
- safety requirements for fixing shingles to roofs and facades, including: job safety analyses and/or safe work method statements in accordance with Safe Work Australia Code of Practice for Construction Work or state and/or territory equivalent
- safety requirements for fixing shingles to roofs and facades, including: safety data sheets (SDS)
- safety requirements for fixing shingles to roofs and facades, including: personal protective equipment (PPE)
- environmental requirements for fixing shingles to roofs and facades
- characteristics and applications of shingle/shake materials: shingles/shakes: terracotta
- characteristics and applications of shingle/shake materials: shingles/shakes: timber
- characteristics and applications of shingle/shake materials: timber shingles/shakes: straight split
- characteristics and applications of shingle/shake materials: timber shingles/shakes: taper split
- characteristics and applications of shingle/shake materials: timber shingles/shakes: hand split
- characteristics and applications of shingle/shake materials: timber shingles/shakes: re-sawn
- processes for installation of roof battens, sarking and flashing: preparation for shingles/shakes on roof surfaces: battened/boarded and sarked
- processes for installation of roof battens, sarking and flashing: preparation for shingles/shakes on roof surfaces: boarded, counter battened and sarked
- types and uses of materials storage and environmentally friendly waste management
- measuring and marking for fixing shingles to roofs and facades
- types and uses of plans, drawings and specifications for fixing shingles to roofs and facades
- types and uses of tools for fixing shingles to roofs and facades
- processes for the calculation of material requirements for fixing shingles to roofs and facades
- quality requirements for fixing shingles to roofs and facades
- types and uses of roof and facade construction systems and structures and shingling considerations: hip finishes: mitred
- types and uses of roof and facade construction systems and structures and shingling considerations: hip finishes: lead
- types and uses of roof and facade construction systems and structures and shingling considerations: hip finishes: ridge
- types and uses of roof and facade construction systems and structures and shingling considerations: hip finishes: metal
- types and uses of roof and facade construction systems and structures and shingling considerations: hip finishes: bonnet
- types and uses of roof and facade construction systems and structures and shingling considerations: roof protrusions: chimneys
- types and uses of roof and facade construction systems and structures and shingling considerations: roof protrusions: dormer windows
- types and uses of roof and facade construction systems and structures and shingling considerations: roof protrusions: two storey insert
- types and uses of roof and facade construction systems and structures and shingling considerations: roof protrusions: skylights
- types and uses of roof and facade construction systems and structures and shingling considerations: roof protrusions: pipes and flues
- types and uses of roof and facade construction systems and structures and shingling considerations: roof protrusions: roof ventilators
- types and uses of roof and facade construction systems and structures and shingling considerations: roof protrusions: cupolas
- types and uses of roof and facade construction systems and structures and shingling considerations: joining at wall corners: butted against boards
- types and uses of roof and facade construction systems and structures and shingling considerations: joining at wall corners: laced with flashing behind for internal
- types and uses of roof and facade construction systems and structures and shingling considerations: joining at wall corners: butted against timber stop for both external and internal
- roof and facade shingling techniques and procedures
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing CPCCRT3006
What does an assessment tool for CPCCRT3006 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for CPCCRT3006 needs to address all 73 unit components: 6 elements with 29 performance criteria, 8 performance evidence requirements, 36 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for CPCCRT3006?
Auditori pulls the current release of CPCCRT3006 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for CPCCRT3006 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing CPCCRT3006 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of CPCCRT3006, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
Your CPCCRT3006 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate CPCCRT3006 free