UETDRSB011 — Maintain high current d.c. equipment and switchgear
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UETDRSB011 must cover
98 assessable components: 3 elements (19 performance criteria), 50 performance evidence and 29 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to maintain high current d.c. switchgear and equipment
- 1.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be done are reviewed and determined
- 1.2Work plan is obtained and confirmed in accordance with workplace requirements, and where relevant, communicated to the appropriate personnel
- 1.3Hazards are identified, risks assessed, and control measures identified and applied
- 1.4Work is prioritised and sequenced for completion in accordance with work plan and workplace requirements
- 1.5Plant, tools, equipment and personal protective equipment (PPE) required for work are determined, obtained and confirmed in working order
- 1.6Work permits are determined in accordance with workplace requirements
- 1.7Liaison and communication issues with authorised personnel, authorities and clients are resolved to facilitate work, as required
- 1.8Worksite is prepared in accordance with the work plan and workplace requirements
2 Maintain high current d.c. switchgear and equipment
- 2.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are applied and monitored
- 2.2Work permits are received and signed in accordance with workplace requirements
- 2.3Lifting, working at heights, working in confined spaces and the use of plant, tools, equipment and PPE are carried out in accordance with workplace requirements
- 2.4High current d.c. switchgear and equipment is maintained in accordance with workplace requirements
- 2.5Quality checks of work are undertaken in accordance with work plan and workplace requirements
- 2.6Incidents or unplanned events are responded to in accordance with workplace requirements
3 Complete work and documentation
- 3.1Completed work is checked for compliance against the work plan and workplace requirements
- 3.2Work permits are signed off in accordance with workplace requirements
- 3.3Worksite is rehabilitated, cleaned and made safe in accordance with workplace requirements
- 3.4Plant, tools and equipment are cleaned, checked and returned to storage, and surplus resources and materials are managed in accordance with workplace requirements
- 3.5Work records, reports and documentation are completed, and where relevant, appropriate personnel notified in accordance with workplace requirements
Performance evidence
- applying relevant legislation, regulations, standards, codes of practice and organisational workplace requirements including:
- work health and safety (WHS)/occupational health and safety (OHS) requirements
- identifying hazards, assessing risks, and identifying, applying and monitoring control measures
- obtaining, inspecting and using relevant personal protective equipment (PPE)
- dealing with an unplanned event on at least one (1) occasion
- obtaining and signing relevant work permits in accordance with workplace requirements
- completing relevant work records, reports and documentation
- using at least five (5) of the following testing equipment on at least one (1) occasion:
- ammeter
- voltmeter
- insulation resistance tester
- micro-ohm tester
- multimeter
- drop-out tester
- using drawings and diagrams including all of the following:
- building layouts
- cable block diagrams
- cable schedules
- operating and substation arrangement diagrams
- wiring diagrams and schematic drawings
- maintaining high current direct current (d.c.) equipment and switchgear on at least six (6) of the following types:
- d.c. circuit breaker
- rectifier transformer
- rectifier
- isolator and link
- harmonic filter
- negative reactor
- energy dissipation resistor
- maintaining high current d.c. associated equipment on at least ten (10) of the following:
- d.c. feeder
- surge arrester
- isolating link
- busbar
- cable
- cable support
- pit and enclosure
- protection/alarm system
- control wiring
- metering
- supervisory interface
- cabinet
- rail earth contactor (REC)
- maintaining protection using at least three (3) of the following types:
- buchholz
- frame leakage
- overcurrent
- earth leakage
- reverse current
- delta I
- diode protection
Knowledge evidence
- relevant legislation, regulations, standards, codes of practice and organisational workplace requirements, including WHS/OHS requirements
- hazard, risk assessment and risk control requirements, including potential hazards
- types and application of PPE
- safe use of plant, tools and equipment
- application, purpose and types of permits
- events constituting an unplanned event or incident
- procedures for responding to an unplanned event or incident
- workplace records, reports and documentation
- work on energised systems
- diagrams, drawings, and manuals, including:
- electrical and mechanical drawings
- operating and substation arrangement diagrams
- manufacturers’ manuals
- specialised tools, including:
- types, construction and function
- calibration
- care and maintenance
- testing equipment, including:
- types, construction and function
- calibration
- care and maintenance
- high current d.c. equipment, associated equipment and switchgear, including:
- types, construction and function
- maintenance procedures
- procedures for checking maintenance tasks for compliance
- high current d.c. protection equipment:
- types, construction and function
- maintenance procedures
- checking maintenance tasks for compliance
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UETDRSB011
What does an assessment tool for UETDRSB011 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UETDRSB011 needs to address all 98 unit components: 3 elements with 19 performance criteria, 50 performance evidence requirements, 29 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UETDRSB011?
Auditori pulls the current release of UETDRSB011 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UETDRSB011 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UETDRSB011 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UETDRSB011, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UETDRSB001 — Perform substation switching operations to a given schedule
- UETDRSB002 — Commission and maintain discrete control and protection systems
- UETDRSB003 — Commission and maintain distribution field devices
- UETDRSB004 — Conduct surveys using thermovision techniques
- UETDRSB005 — Diagnose and resolve faults in a substation environment
- UETDRSB006 — Inspect substations
- UETDRSB007 — Install and maintain substation direct current systems
- UETDRSB008 — Install high current d.c. equipment and switchgear
- UETDRSB009 — Install high voltage plant and equipment
- UETDRSB010 — Maintain capacitor bank equipment
- UETDRSB012 — Maintain high voltage circuit breakers
- UETDRSB013 — Maintain on-load tap changers (OLTC)
Your UETDRSB011 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UETDRSB011 free