UETDRSB010Maintain capacitor bank equipment

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UETDRSB010 must cover

73 assessable components: 3 elements (18 performance criteria), 25 performance evidence and 30 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to maintain capacitor bank equipment

  • 1.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are reviewed and determined
  • 1.2Work plan is obtained, confirmed and communicated with relevant personnel in accordance with workplace requirements
  • 1.3Hazards are identified, risks assessed, and control measures identified and applied
  • 1.4Work is prioritised and sequenced for completion in accordance with work plan and workplace requirements
  • 1.5Plant, tools, equipment and personal protective equipment (PPE) required for work are determined, obtained and confirmed in working order
  • 1.6Liaison and communication issues with authorised personnel, authorities and clients are resolved to facilitate work, as required
  • 1.7Worksite is prepared in accordance with the work plan and workplace requirements

2 Maintain capacitor bank equipment

  • 2.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are applied and monitored
  • 2.2Work permits are received and signed in accordance with workplace requirements
  • 2.3Lifting, working at heights, working in confined spaces and the use of plant, tools, equipment and PPE are carried out in accordance with workplace requirements
  • 2.4Capacitor bank equipment is maintained in accordance with workplace requirements
  • 2.5Quality checks of work are undertaken in accordance with work plan and workplace requirements
  • 2.6Incidents or unplanned events are responded to in accordance with workplace requirements

3 Complete work and documentation

  • 3.1Completed work is checked for compliance against the work plan and workplace requirements
  • 3.2Work permits are signed off in accordance with workplace requirements
  • 3.3Worksite is rehabilitated, cleaned and made safe in accordance with workplace requirements
  • 3.4Plant, tools and equipment are cleaned, checked and returned to storage, and surplus resources and materials are managed in accordance with workplace requirements
  • 3.5Work records, reports and documentation are completed, and where relevant, appropriate personnel notified in accordance with workplace requirements

Performance evidence

  • applying relevant legislation, regulations, standards, codes of practice and organisational workplace requirements including:
  • work health and safety (WHS)/occupational health and safety (OHS) requirements
  • identifying hazards, assessing risks, identifying, applying and monitoring control measures
  • obtaining, inspecting and using relevant personal protective equipment (PPE)
  • dealing with an unplanned event on at least one (1) occasion
  • obtaining and signing relevant work permits in accordance with workplace requirements
  • completing relevant work records, reports and documentation
  • maintaining at least two (2) of the following types of capacitor bank systems:
  • double star neutral current unbalance
  • voltage unbalance
  • floating star
  • earthed star
  • harmonic filter
  • series
  • maintaining at least two (2) of the following components:
  • internal discharge resistor cans
  • external resistor type
  • switching reactors
  • neutral unbalance current transformer
  • performing at least three (3) of the following types of tests:
  • insulation resistance
  • capacitance
  • unbalance current/voltage
  • primary injection
  • high voltage (HV) direct current d.c. withstand

Knowledge evidence

  • relevant legislation, regulations, standards, codes of practice and organisational workplace requirements, including WHS/OHS requirements
  • hazard, risk assessment and risk control requirements, including potential hazards
  • types and application of PPE
  • safe use of plant, tools and equipment
  • application, purpose and types of permits
  • events constituting an unplanned event or incident
  • procedures for responding to an unplanned event or incident
  • workplace records, reports and documentation
  • operational manuals and system diagrams
  • capacitor banks, including:
  • types
  • characteristics
  • isolation and discharge
  • maintenance requirements
  • common defects and rectification
  • testing, including:
  • insulation resistance
  • capacitance
  • unbalance current/voltage
  • primary injection
  • HV direct current d.c. withstand
  • ancillary components, including:
  • internal discharge resistor cans
  • external resistor type
  • switching reactors
  • neutral unbalance current transformer
  • specialised tools, including:
  • types, construction and function
  • calibration
  • care and maintenance

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UETDRSB010

What does an assessment tool for UETDRSB010 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UETDRSB010 needs to address all 73 unit components: 3 elements with 18 performance criteria, 25 performance evidence requirements, 30 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UETDRSB010?

Auditori pulls the current release of UETDRSB010 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UETDRSB010 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UETDRSB010 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UETDRSB010, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UETDRSB010 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UETDRSB010 free