UETDRDS019Design distribution substations

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UETDRDS019 must cover

34 assessable components: 3 elements (14 performance criteria), 14 performance evidence and 6 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to design distribution substations

  • 1.1Project requirements are determined
  • 1.2Design specifications are determined in accordance with workplace requirements
  • 1.3Tools, equipment and personal protective equipment (PPE) required for site inspections are determined, obtained and confirmed in working order
  • 1.4Requirements for site inspections are determined in accordance with workplace requirements
  • 1.5Work is prioritised and sequenced for completion in accordance with workplace requirements

2 Design distribution substations

  • 2.1Site inspection is performed
  • 2.2Distribution substations are designed in accordance with workplace requirements
  • 2.3Systems modelling is used to evaluate and determine best outcomes in accordance with workplace requirements
  • 2.4Sustainable energy principles are used to evaluate and determine best outcomes in accordance with workplace requirements
  • 2.5Design is checked for compliance against legislation, regulations, standards and codes of practice
  • 2.6Health and safety risks are identified and minimised or eliminated by using safety and control measures in the design process
  • 2.7Quality checks of work are undertaken in accordance with workplace requirements

3 Complete work and documentation

  • 3.1Completed work is checked against project and workplace requirements
  • 3.2Work records, reports and documentation are completed, approved and appropriate personnel notified in accordance with workplace requirements

Performance evidence

  • determining project requirements
  • determining design specifications
  • obtaining, inspecting and using relevant personal protective equipment (PPE) for site inspection
  • determining requirements for site inspections in accordance with workplace requirements
  • prioritising and sequencing work for completion in accordance with workplace requirements
  • performing at least one (1) site inspection
  • demonstrating use of systems modelling to evaluate and determine best outcomes
  • applying sustainable energy principles and practices
  • checking design for compliance against legislation, regulations, standards and codes of practice
  • identifying, and minimising or eliminating health and safety risks by using safety and control measures
  • performing ongoing quality checks of work in accordance with workplace requirements
  • checking final design against project and workplace requirements
  • completing six (6) designs from at least two (2) of the following project types: single transformer substations, multi-transformer substation, upgrade/alteration to existing assets
  • drafting all of the following for each design: single line diagram, above ground layout diagram, earthing layout diagram, primary plant dimensioning checklist, standards compliance checklist, hazard identification, risk assessment and control measures

Knowledge evidence

  • distribution substation design, including: project requirements, design specifications, hazard, risk assessment and risk control requirements, including potential hazards, types and application of PPE, site inspections, use of systems modelling for best outcomes, application of sustainable energy principles and practices, compliance with legislation, regulations, standards, codes of practice, and project and workplace requirements, work records, reports and documentation, manuals, diagrams and drawings, the purpose and features of typical co-generation systems and associated network constraints
  • substations and power transformers including: characteristics, testing and commissioning, maintenance, metering and control equipment, switchgear, earthing, surge protection, auxiliary equipment
  • transformers, including: types, characteristics, basic construction, operation under load/no-load conditions, types and operation of tap changing switches, efficiency and cooling, auxiliary equipment, maintenance, restrictions to parallel operation, harmonics issues and remedies, testing and fault-finding procedures
  • high voltage (HV) switchgear, including: protection and alarms, operating limitations, protection device rating, switching equipment and practices, paralleling requirements, isolation and earthing procedures, common distribution faults
  • automation systems, including: function, main components, operation procedure
  • layout principles for a distribution substation including: relationship to overall power system, purpose, location, equipment layout, fire and oil management, including bund design, flame traps, oil/water separation systems

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UETDRDS019

What does an assessment tool for UETDRDS019 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UETDRDS019 needs to address all 34 unit components: 3 elements with 14 performance criteria, 14 performance evidence requirements, 6 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UETDRDS019?

Auditori pulls the current release of UETDRDS019 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UETDRDS019 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UETDRDS019 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UETDRDS019, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UETDRDS019 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UETDRDS019 free