UEGNSG313Monitor and operate flow control, pressure measuring and regulating devices for gas transmission

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UEGNSG313 must cover

50 assessable components: 3 elements (27 performance criteria), 9 performance evidence and 14 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to monitor complex gas flow control device and equipment

  • 1.1Work requirements for monitoring and operating complex gas flow control, pressure measuring and regulating device/s are interpreted from plan/s, specifications and instructions
  • 1.2Relevant gas supply monitoring requirements and workplace procedures for work are communicated to relevant person/s
  • 1.3Work health and safety (WHS)/occupational health and safety (OHS), environmental and sustainable energy workplace policies and procedures related to gas supply monitoring and operating of complex flow controls are obtained and confirmed
  • 1.4Work activities are prioritised and sequenced following consultation with relevant person/s for completion within acceptable timeframes and in accordance with workplace procedures
  • 1.5WHS/OHS and environmental risk control measures for identified hazards are prioritised, implemented and monitored
  • 1.6Relevant work permits are obtained to access, isolate/de-energise systems and perform work in accordance with job requirements and workplace procedures
  • 1.7Resources, appropriately licensed person/s, equipment, tools and personal protective equipment (PPE) required for the work are identified, scheduled and obtained in safe working order
  • 1.8Liaison and communication with authorised person/s, authorities, clients and land owners are undertaken to resolve gas supply issues and work activities monitored in accordance with workplace procedures
  • 1.9Person/s participating in work activities are fully briefed and respective responsibilities confirmed, as required, in accordance with workplace procedures
  • 1.10Third-party issues are referred to appropriate person/s in accordance with workplace procedures
  • 1.11Site preparation, safety plan and work schedule are confirmed in accordance with workplace procedures

2 Monitor complex gas flow control device and equipment system performance

  • 2.1WHS/OHS and environmental workplace policies, procedures and safe work practices are followed to eliminate or minimise risk of harm from incidents and hazards
  • 2.2Information on gas supply device and equipment performance is collected and reported in accordance with organisational requirements
  • 2.3Dealings with customers are consistent with workplace procedures and specific needs of customer/s are identified and considered in targeting client service
  • 2.4Routine inspections of system are scheduled and monitored in accordance with the work schedule and workplace procedures
  • 2.5Hazard warnings and safety signs are recognised and hazards are identified, assessed and WHS/OHS risks are reported to the authorised person/s for directions in accordance with workplace procedures
  • 2.6System performance data and usage is collected, analysed and reported with any unplanned events from monitoring operation of complex gas flow control in accordance with workplace procedures
  • 2.7Samples are taken in accordance with workplace procedures and known solutions to a variety of problems are applied
  • 2.8Ongoing checks of quality of work are undertaken in accordance with given instructions and workplace procedures

3 Control and adjust gas flow and complete records and reports

  • 3.1Gas flow and overflow regulating systems are inspected and adjusted to meet demand and customer requirements
  • 3.2Incidents and injuries are reported in accordance with workplace procedures, as required
  • 3.3Gas flow and diversion/s are determined to facilitate repair or emergency activities in accordance with organisational requirements
  • 3.4Process faults and operational conditions of the gas transmission system are identified, addressed and reported in accordance with organisational requirements
  • 3.5Work site is cleaned up and confirmed safe in accordance with workplace procedures
  • 3.6Tools, equipment and any surplus resources and materials are cleaned, checked and returned to storage in accordance with workplace procedures
  • 3.7Relevant work permit/s are signed off in accordance with job requirements
  • 3.8Work completion records, reports and documentation are finalised and processed and appropriate person/s notified

Performance evidence

  • applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including:
  • workplace procedures and practices
  • using risk control measures
  • applying sustainable energy principles and practices
  • completing records and reports
  • controlling and adjusting gas supply flow
  • dealing effectively with unplanned events in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
  • monitoring and operating of complex gas flow control, measuring and regulating devices for gas pressure and flow control in gas transmission systems in accordance with relevant legislation, code of practice, regulations and workplace procedures
  • monitoring gas supply system performance

Knowledge evidence

  • differences in pipeline pressures, including high/low flow pressures
  • gas conditioning and monitoring equipment, including principles of operation, fault finding, adjustments, replacement and minor repairs
  • gas facilities/station venting, purging and pressurisation operations
  • gas flow measurement equipment types
  • gas pressure control equipment, including principles of operation
  • gas transmission pipeline flow control, pressure, measuring and regulating devices
  • gas transmission systems relevant legislation, codes of practice and regulations
  • monitoring and operating complex flow control, measuring and regulating devices on gas transmission systems
  • principles of control systems used in monitoring and control of applicable organisational gas infrastructure
  • relevant manufacturer specifications, manuals and procedures
  • relevant safe work method statements (SWMS)/job safety assessments or risk mitigation processes including safe working practices
  • relevant WHS/OHS legislated requirements
  • relevant workplace documentation, records and reports
  • relevant workplace policies and procedures

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEGNSG313

What does an assessment tool for UEGNSG313 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEGNSG313 needs to address all 50 unit components: 3 elements with 27 performance criteria, 9 performance evidence requirements, 14 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEGNSG313?

Auditori pulls the current release of UEGNSG313 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEGNSG313 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEGNSG313 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEGNSG313, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEGNSG313 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEGNSG313 free