UEERE0078Install battery storage to power conversion equipment

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UEERE0078 must cover

59 assessable components: 2 elements (15 performance criteria), 11 performance evidence and 33 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Plan for the installation of battery storage to PCE

  • 1.1Nature of the installation is verified from design documentation and any design concerns identified are referred to designer
  • 1.2WHS/OHS processes and procedures for work are identified and applied in accordance with workplace procedures
  • 1.3Hazards associated with battery storage systems are identified and the risk control measures are listed in safe work method statements/job safety analysis
  • 1.4Work is planned in consultation with the customer and others impacted by the work and sequenced appropriately
  • 1.5Designer recommendations, relevant industry standards, regulations and manufacturer specifications are identified and applied to planning the system installation
  • 1.6Material, tools, equipment and measuring devices required for installation are obtained in accordance with workplace procedures and checked for correct operation and safety
  • 1.7Live testing, measurement and isolation requirements determined and applied in accordance with WHS/OHS requirements and workplace procedures

2 Install battery storage systems to PCE

  • 2.1Job safety analysis is undertaken or safe work method statement is prepared and used to inform work processes in accordance with regulations and workplace procedures
  • 2.2Battery storage system components are installed in compliance with industry standards, regulations and job/manufacturer specifications, and with sufficient access to enable terminations, adjustment and maintenance
  • 2.3Wiring is terminated at components and associated equipment in accordance with manufacturer specifications and functional and regulatory requirements
  • 2.4System components are programmed in accordance with design, relevant industry standards, regulations and manufacturer specifications
  • 2.5Quality checks of installed apparatus are conducted in accordance with workplace procedures
  • 2.6Testing and commissioning of the system is conducted in accordance with design documentation, regulations, relevant industry standards and manufacturer specifications
  • 2.7Worksite is cleaned and made safe in accordance with workplace procedures
  • 2.8'As-installed' system and associated equipment are documented, manuals produced, and system is handed over to required person/s as per legislation, regulations, industry standards and job requirements

Performance evidence

  • interpreting system design and verifying installation compliance with relevant industry standards, manufacturer specifications, building codes and regulations and any noncompliance referred to designer
  • applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures
  • coordinating work with relevant person/s
  • determining and applying live testing, measurement and isolation requirements
  • installing battery storage components
  • installing PCE
  • installing balance of system to PCE
  • program components
  • testing and commissioning battery storage system
  • completing required documentation
  • instruct client on safe and correct system operation recommended maintenance and system documentation

Knowledge evidence

  • meaning of the terms that define aspects of batteries including: battery, cell, primary and secondary cells, charge and discharge rate, depth of discharge (DOD), nominal voltage, amp hour capacity, state of charge (SOC), watt hour capacity, usable capacity, cycle life
  • major features of commercially available types of batteries suitable for battery storage systems
  • factors affecting the life of commercially available types of batteries including the estimation of battery life
  • common reasons for failure of commercially available batteries
  • charging regimes suitable for commercially available types of batteries
  • hazards associated with handling, installing or maintaining commercially available types of batteries and risk control measures
  • hazards during fault conditions
  • procedures for safe disposal and recycling of commercially available types of batteries
  • applications for battery storage including: electrical energy supply during grid outages, electrical energy supply direct to loads during periods of high tariffs, network / aggregator provider requirements
  • purpose of each component in battery storage systems for PV systems
  • communications, monitoring and metering
  • objectives of battery storage
  • purpose of each component in a battery storage system for PV system
  • typical configurations of battery storage systems for PV systems
  • types and applications of PCEs
  • electrical systems circuit diagrams of typical battery storage systems
  • all major components
  • protection devices
  • earthing
  • isolation
  • switching
  • metering
  • equipment location plan/s to show the locations of equipment, fittings and cabling
  • single line diagrams of battery storage systems
  • site diagrams to show the locations of equipment, fittings and cabling
  • power conversion equipment
  • fault finding procedures including: fault finding procedures for individual equipment, fault finding procedures for interconnected systems
  • maintenance requirements including relevant industry standards, regulations and manufacturer requirements
  • maintenance requirements for individual equipment
  • maintenance requirements for interconnected systems
  • safe testing of equipment
  • safe testing of system operation
  • commissioning of energy storage system

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEERE0078

What does an assessment tool for UEERE0078 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERE0078 needs to address all 59 unit components: 2 elements with 15 performance criteria, 11 performance evidence requirements, 33 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEERE0078?

Auditori pulls the current release of UEERE0078 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERE0078 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEERE0078 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERE0078, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEERE0078 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEERE0078 free