UEERE0061 — Design grid-connected photovoltaic power supply systems
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEERE0061 must cover
49 assessable components: 2 elements (8 performance criteria), 3 performance evidence and 38 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to design a grid-connected PV power supply system
- 1.1Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures are identified and applied
- 1.2Potential grid-connected supply system options are determined from interpretation of site survey and available information
- 1.3People or organisations involved in the design and installation are identified and roles clarified
- 1.4Industry regulations, legal obligations and job requirements are identified and applied to work in accordance with workplace procedures
2 Develop a grid-connected PV power supply system design
- 2.1Grid-connected power supply systems, performance standards and compliance methods are applied to the design development
- 2.2Safety, functional and budgetary considerations are incorporated in design
- 2.3Grid-connected power supply system design draft is checked for compliance with the design brief, industry standards and regulations, job requirements and workplace procedures
- 2.4Grid-connected power supply system design is documented and submitted in line with industry standards and regulations, job requirements and workplace procedures
Performance evidence
- applying relevant workplace procedures and practices, work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures
- developing grid-connected photovoltaic (PV) power supply system design based on site survey data and within safety and functional requirements and budget limitations and meet design brief
- documenting and presenting final design
Knowledge evidence
- solar resource including: peak sun hours, irradiance, irradiation, latitude, azimuth and altitude angles, tilt angle
- interpretation of solar irradiation data
- how irradiation varies throughout the year on the surface of a fixed collector
- factors affecting the optimal tilt and orientation of PV arrays
- effect on solar resource of tracking
- PV modules, including: cell, module, array
- types, efficiencies and their typical applications
- mechanical and electrical features necessary for the long life of a PV module
- module characteristics including: I-V curve, operating point, MPP, power and voltage temperature co-efficient, Standard Test Conditions (STC), nominal operating cell temperature (NOCT)
- major ratings of a PV module from manufacturer’s information or nameplate data
- configuration of a typical PV array
- the effect of partial shading of a PV module or array
- relevant industry standard requirements for installation of grid-connected PCE
- verification of site survey data and application in design
- PV arrays selection including: selection and sizing of PV array for a grid-connected power conversion equipment (PCE), based on energy demand, budget constraints, architectural constraints or limitations on available PCE sizes
- determining the minimum and maximum number of PV modules in a string for the specified voltage
- system components selection including: balance of the system components, including cabling and wiring systems, circuit protection and isolation equipment for a grid-connected PV system
- schematic diagrams of common grid-connected PCE circuit configurations, including metering arrangements, isolation and connection with respect to residual circuit devices (RCDs)
- other design considerations including: energy yield, specific energy yield
- calculation of incentives
- regulatory and legal obligations
- PCEs including: types of PCEs used in grid connected systems
- the basic function of PCEs
- PCE operation
- PCE characteristics
- PV grid-connected system operation including operation of grid interactive safety requirements
- grid-connected PCE selection including: operating window of the PCE for the expected minimum and maximum effective cell temperatures
- selection of an PCE rating with respect to the output power of the array/s
- major installation requirements for all system components which will ensure correct operation, long life, safety and ease of maintenance consistent with industry standards and relevant WHS/OHS guidelines
- selection of a suitable location for the PV array, PCE and other components, at a given installation site
- typical installation configurations for grid connection of PV systems via power conversion equipment
- installation requirements for a grid connected system
- labelling and signage requirements
- relevant manufacturer specifications
- relevant risk mitigation processes
- relevant WHS/OHS legislated requirements
- relevant workplace documentation
- relevant workplace policies and procedures
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEERE0061
What does an assessment tool for UEERE0061 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERE0061 needs to address all 49 unit components: 2 elements with 8 performance criteria, 3 performance evidence requirements, 38 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEERE0061?
Auditori pulls the current release of UEERE0061 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERE0061 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEERE0061 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERE0061, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEERE0001 — Apply environmentally and sustainable procedures in the energy sector
- UEERE0006 — Conduct periodic maintenance of remote area power supply battery banks
- UEERE0007 — Conduct periodic maintenance of remote area power supply generator sets
- UEERE0008 — Conduct periodic maintenance of remote area power supply photovoltaic arrays
- UEERE0009 — Conduct periodic maintenance of remote area power supply wind generators
- UEERE0013 — Develop strategies to address environmental and sustainability issues in the energy sector
- UEERE0015 — Implement and monitor energy sector environmental and sustainable policies and procedures
- UEERE0018 — Maintain and repair remote area power generation facilities
- UEERE0049 — Apply safe work practices in the rooftop solar industry
- UEERE0050 — Identify and isolate multiple supply systems
- UEERE0051 — Apply electrical principles to renewable energy design
- UEERE0052 — Assess energy loads and uses for energy efficiency in commercial facilities
Your UEERE0061 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEERE0061 free