MEM24022 — Undertake penetrant tests
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for MEM24022 must cover
45 assessable components: 5 elements (23 performance criteria), 11 performance evidence and 11 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Establish job requirements
- 1.1Comply with relevant WHS and regulatory requirements, codes of practice, standards and standard operating procedures (SOPs) for penetrant testing
- 1.2Identify job requirements from specifications, drawings, job sheets or work instructions
2 Prepare for testing
- 2.1Liaise with client to explain testing requirements and schedule tests
- 2.2Use established safe work practices and personal protective equipment to ensure personal safety and that of others
- 2.3Assemble all specified testing equipment, materials and containers and safety equipment
- 2.4Identify inspection areas and determine if special access requirements appropriate for the NDT test need to be communicated to the client
- 2.5Clean and prepare inspection areas for testing using appropriate test procedures and materials
- 2.6Assess inspection areas visually and identify obvious discontinuities.
3 Conduct penetrant tests
- 3.1Select the most appropriate penetrant test technique for the material or application
- 3.2Select test equipment and conduct pre-use checks in accordance with relevant standards and/or procedures
- 3.3Select and apply appropriate test media in accordance with workplace/industry practices
- 3.4Conduct penetrant tests in accordance with relevant standards and work instructions
- 3.5Minimise environmental impacts of testing and generation of waste
4 Interpret and report the results of penetrant tests
- 4.1Review conduct of the test and confirm test procedures were applied correctly
- 4.2Monitor and assess indications and determine the type of discontinuity for each relevant indication
- 4.3Apply acceptance criteria to discontinuities to detect defects
- 4.4Classify defects in accordance with relevant national and international codes and standards
- 4.5Confirm defects in accordance with workplace procedures and industry practices
- 4.6Seek advice for problems outside technical competence or knowledge
- 4.7Record any site observations that may affect results
- 4.8Report test results and complete all job records in accordance with relevant standards and SOPs
5 Maintain a safe work environment
- 5.1Restore test site, clean inspection area and equipment and dispose of all waste in accordance with enterprise procedures
- 5.2Store and maintain penetrant testing equipment in accordance with standard operating procedures and WHS requirements.
Performance evidence
- preparing the inspection area on at least two specimens for testing and identifying discontinuities including observed changes in material homogeneity in accordance with procedures
- complying with workplace procedures and WHS requirements at all times during penetrant testing
- identifying and interpreting specifications, standards, drawings, charts, lists and other reference material for performing penetrant testing on at least two specimens
- selecting the most appropriate penetrant test technique for the material or application
- undertaking penetrant testing using three or more of the following techniques on at least two specimens: colour contrast water wash, colour contrast solvent remover, fluorescent water wash, fluorescent solvent remover, fluorescent post emulsified, process penetrant line methods using automated/mechanised timed systems
- applying test media and undertaking penetrant testing using appropriate techniques for the materials in at least two specimens
- checking/confirming indicators and identifying all defects including accurate identification of location and size of discontinuities and defects for at least two specimens
- classifying all defects for at least two specimens in accordance with national and international codes and standards
- performing measurements associated with penetrant testing on at least two specimens
- reporting test results for at least two specimens in accordance with workplace procedures and customer service requirements
- conducting all required testing with minimal environmental impact.
Knowledge evidence
- principles, applications and limitations of penetrant testing techniques
- requirements of any applicable standards, Safe Work Australia guidelines, State/Territory regulatory codes of practice/standards to penetrant testing
- penetrant testing techniques, methods and procedures for the range of situations used in job role
- tools, equipment, instruments
- cleaning and preparation processes and procedures, statutory and WHS requirements relevant to the preparation process
- established procedures and techniques for assessment of test results
- types of discontinuities and their consequences/effect on the material
- range of defects, common faults and damage to test equipment and materials
- implications of test results for the particular material/application
- methods and procedures for recording and reporting test results
- maintenance and storage procedures for test equipment.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing MEM24022
What does an assessment tool for MEM24022 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MEM24022 needs to address all 45 unit components: 5 elements with 23 performance criteria, 11 performance evidence requirements, 11 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for MEM24022?
Auditori pulls the current release of MEM24022 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MEM24022 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing MEM24022 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MEM24022, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- MEM03001 — Perform manual production assembly
- MEM03002 — Perform precision assembly
- MEM03003 — Perform sheet and plate assembly
- MEM03004 — Perform electronic/electrical assembly (production)
- MEM03005 — Rework and repair (electrical/electronic production)
- MEM03006 — Set assembly stations
- MEM04001 — Operate melting furnaces
- MEM04002 — Perform gravity die casting
- MEM04003 — Operate pressure die casting machine
- MEM04004 — Prepare and mix sand for metal moulding
- MEM04006 — Operate sand moulding and core making machines
- MEM04007 — Pour molten metal
Your MEM24022 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate MEM24022 free