MEM18049 — Disconnect/reconnect fixed wired equipment up to 1000 volts a.c./1500 volts d.c.
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for MEM18049 must cover
46 assessable components: 4 elements (22 performance criteria), 10 performance evidence and 14 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Determine job requirements
- 1.1Follow standard operating procedures (SOPs)
- 1.2Comply with work health and safety (WHS) requirements at all times
- 1.3Use appropriate personal protective equipment (PPE) in accordance with SOPs
- 1.4Identify job requirements from specifications, drawings, job sheets or work instructions
2 Disconnect equipment
- 2.1Determine electrical characteristics of equipment and circuit by reference to circuit drawings, schematics, reference manuals, equipment specifications, identification plate and/or consultation with technical adviser
- 2.2Determine and record equipment characteristics, including direction of rotation, where appropriate
- 2.3Identify point/s of electrical isolation and isolate equipment in accordance with procedures
- 2.4Use all lock-off equipment and signage requirements appropriately
- 2.5Prove electrical isolation using appropriate techniques, procedures and test equipment
- 2.6Note, record and label conductor layout
- 2.7Disconnect conductors and terminate and make safe disconnected cables/connections
3 Connect equipment
- 3.1Identify characteristics of the equipment to be connected and determine connection requirements
- 3.2Check circuit for safe isolation using appropriate test equipment, procedures and techniques
- 3.3Check connections and prepare conductors for termination
- 3.4Connect conductors to equipment in accordance with specifications and regulatory requirements
- 3.5Fasten/seal all cables/wires/conduit to specifications
- 3.6Remove all lock-off equipment and signage
- 3.7Check and test equipment and circuit for compliance with specifications and regulatory and legislative requirements
4 Perform emergency first aid
- 4.1Assess situation to identify points of danger to the injured person and potential rescuer
- 4.2Undertake rescue/recovery of injured person or provide assistance to injured person in accordance with recognised standards/procedures
- 4.3Make contact with the appropriate medical and rescue authorities
- 4.4Record details of first aid given
Performance evidence
- following work instructions, standard operating procedures (SOPs) and safe work practices
- identifying and interpreting specifications, charts, lists, circuit drawings, schematics, regulatory and legislative requirements to disconnect/reconnect fixed wired equipment up to 1000 volts a.c./1500 volts d.c.
- checking that the electrical equipment is isolated and tagged where necessary in strict accordance with work health and safety (WHS) requirements and procedures using appropriate lock-off equipment and tags/signs
- disconnecting equipment by labelling and recording conductors and making safe disconnected cables/connections using appropriate tools, test equipment, procedures and techniques
- confirming isolation prior to reconnecting fixed wired equipment and checking connections and preparing conductors for termination in accordance with manufacturers’ specifications and regulatory requirements
- connecting conductors to equipment and fasten/seal cables/wires/conduits using appropriate procedures and tools to relevant specifications and regulatory requirements
- testing terminated cables to ensure continuity and insulation resistance and complying with following requirements: checking continuity of the protective earth conductor to determine whether it is sufficiently low; testing the resistance between the protective earth conductor and the neutral conductor to determine whether it is sufficiently low – not greater than 2 Ohms; testing the insulation resistance of active conductors to confirm that it is greater than 1 Megohm
- removing all lock-off devices and signage and checking/testing equipment and circuits for compliance to specifications
- rescuing/recovering of injured person in accordance with appropriate standards/procedures and providing first aid, where appropriate, including contacting the appropriate medical and rescue authorities
- recording details of first aid given.
Knowledge evidence
- safe work practices and procedures and use of personal protective equipment (PPE)
- basic knowledge of electrical theory for the operation of the circuit/equipment
- relevant regulatory requirements
- procedures for: determining and recording equipment characteristics; proving and removing electrical isolation; labelling conductors and recording conductor layout; disconnecting conductors and terminating disconnected cables/connections; terminating conductors and checking connections and specifications that apply; connecting conductors to equipment; fastening and sealing the cables, wires and conduits and tools, techniques and equipment to be used; checking and testing the compliance of the equipment with specifications and tools, techniques and equipment to be used; recording first aid
- tools, techniques and equipment required to determine equipment characteristics, prove electrical isolation and disconnect/reconnect and terminate conductors
- point(s) of isolation for the fixed wired equipment and reasons for selecting the chosen isolation point(s)
- safe isolation and proving dead
- range of isolation procedures for the fixed wired equipment
- lock-off equipment and signs to be used and reasons for using and procedures for lock-off equipment and signage
- characteristics of the circuit and the equipment
- operational specifications of the fixed wired equipment
- points of danger to the injured person or potential rescuer
- recognised procedures for the movement and treatment of the injured person, including safe rescue of victim from a live situation, clearing of airways, care of spinal injuries, treatment of cuts/lesions, burns/scalds and treatment of shock
- appropriate local medical and rescue services.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing MEM18049
What does an assessment tool for MEM18049 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MEM18049 needs to address all 46 unit components: 4 elements with 22 performance criteria, 10 performance evidence requirements, 14 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for MEM18049?
Auditori pulls the current release of MEM18049 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MEM18049 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing MEM18049 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MEM18049, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- MEM03001 — Perform manual production assembly
- MEM03002 — Perform precision assembly
- MEM03003 — Perform sheet and plate assembly
- MEM03004 — Perform electronic/electrical assembly (production)
- MEM03005 — Rework and repair (electrical/electronic production)
- MEM03006 — Set assembly stations
- MEM04001 — Operate melting furnaces
- MEM04002 — Perform gravity die casting
- MEM04003 — Operate pressure die casting machine
- MEM04004 — Prepare and mix sand for metal moulding
- MEM04006 — Operate sand moulding and core making machines
- MEM04007 — Pour molten metal
Your MEM18049 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate MEM18049 free