MEM18022Maintain fluid power controls

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for MEM18022 must cover

58 assessable components: 6 elements (29 performance criteria), 10 performance evidence and 19 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Determine job requirements

  • 1.1Follow standard operating procedures (SOPs)
  • 1.2Comply with work health and safety (WHS) requirements at all times
  • 1.3Use appropriate personal protective equipment (PPE) in accordance with SOPs
  • 1.4Identify job requirements from specifications, drawings, job sheets or work instructions

2 Install/replace fluid power systems and controls

  • 2.1Interpret and apply fluid power control principles and system/circuit diagrams
  • 2.2Identify system/circuit components and inspect for compliance with specifications
  • 2.3Undertake sequential installation according to manufacturers’ specifications and SOPs

3 Check and adjust fluid power system control sequence and operation

  • 3.1Check controls and system operation against operational specifications using appropriate test equipment and application principles/techniques
  • 3.2Perform adjustments to sequence system to meet/align to operational requirements and specifications
  • 3.3Report modifications/alterations and according to SOPs
  • 3.4Check controls and system operation and commission to specifications

4 Fault find fluid power systems control circuit

  • 4.1Interpret and apply system/circuit diagrams and data sheets
  • 4.2Identify and inspect system/circuit components
  • 4.3Trace system/circuit and diagnose action of components to identify and localise faults
  • 4.4Test system/circuit parts using appropriate test equipment and application principles
  • 4.5Assess system/circuit parts against operational specifications
  • 4.6Localise fault condition at the component level
  • 4.7Evaluate faulty condition, analyse root cause and plan corrective action

5 Maintain, and repair or rectify system control components

  • 5.1Apply correct maintenance procedures
  • 5.2Select and apply repair procedures using appropriate tools, equipment and techniques
  • 5.3Test faulty items, repair or replace using sequential installation procedures according to manufacturers’ recommendations
  • 5.4Select replacement items from appropriate sources
  • 5.5Reassemble system control components according to specifications

6 Check and adjust sequence of fluid power system controls

  • 6.1Identify circuit sensors and controllers using circuit diagrams and fluid power system control principles
  • 6.2Make necessary adjustments to sequence system control circuit to meet operational specification
  • 6.3Check and verify correct operation of system control circuit against operational specification
  • 6.4Commission fluid power system controls to specifications
  • 6.5Adopt appropriate follow-up procedures
  • 6.6Complete service/maintenance report

Performance evidence

  • following work instructions, standard operating procedures (SOPs) and safe work practices
  • obtaining and interpreting specifications system/circuit diagrams, system operation data sheets and control data and identifying and inspecting system components for compliance with specifications
  • planning and undertaking sequential installation of fluid power systems and controls in accordance with manufacturers’ specifications and procedures
  • checking and adjusting control and system operation using appropriate test equipment ensuring that the sequence of operations conforms to specifications and operational requirements
  • recording/reporting any modifications/alterations to the system in accordance with standard operating procedures
  • fault-finding fluid power systems control circuit using fault-finding techniques and appropriate test equipment and identifying and localising components not conforming to operational specifications for repair/replacement
  • repairing/replacing faulty items after testing for compliance to specifications using appropriate tools, equipment and techniques
  • reassembling control components to meet specifications
  • verifying correct operation of system power control circuit and commissioning the fluid power system controls to specifications
  • initiating maintenance and/or service follow-up procedures and completing maintenance and/or service reports according to standard operating procedures

Knowledge evidence

  • safe work practices and procedures and use of personal protective equipment (PPE)
  • system operational and control requirements and specifications
  • application of common fluid power system components and controllers
  • system/circuit components
  • special installation requirements
  • fluid power and common test equipment and their application
  • correct operational sequence of the system
  • typical adjustments to correct sequencing variations from specification
  • procedures for recording/reporting modifications/alterations and consequences of not recording/reporting
  • fluid power system commissioning procedures
  • component(s) not complying with operational specification and typical causes of component failure
  • cause of the faulty condition in the component(s) and appropriate procedures for rectifying the faulty condition
  • appropriate maintenance schedule and procedures
  • appropriate control component repair procedures
  • typical test equipment and applications
  • circuit sensors and controllers
  • common adjustments that can be made to control systems and their effect
  • any maintenance/service follow-up procedures
  • maintenance/service recording/reporting requirements

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing MEM18022

What does an assessment tool for MEM18022 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MEM18022 needs to address all 58 unit components: 6 elements with 29 performance criteria, 10 performance evidence requirements, 19 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for MEM18022?

Auditori pulls the current release of MEM18022 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MEM18022 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing MEM18022 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MEM18022, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your MEM18022 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate MEM18022 free