MEM10024 — Install and troubleshoot luminaires and ancillary equipment
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for MEM10024 must cover
87 assessable components: 3 elements (17 performance criteria), 22 performance evidence and 48 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Determine job requirements
- 1.1Follow standard operating procedures (SOPs)
- 1.2Comply with work health and safety (WHS) requirements at all times, including appropriate risk control measures
- 1.3Use appropriate personal protective equipment (PPE) in accordance with SOPs
- 1.4Determine through the interpretation of electrical diagrams, drawings, lighting standards and/or from consultation the luminaire and ancillary equipment requirements for the electrical installation
2 Install luminaires and ancillary equipment
- 2.1Obtain the number and type of luminaires and associated ancillary equipment through established procedures
- 2.2Obtain necessary tools, equipment and testing instruments needed for installing luminaires and ancillary equipment
- 2.3Isolate and tag circuits and equipment in accordance with procedures, where required
- 2.4Install luminaires and accessories complying with job specifications, and regulatory and legislative requirements
- 2.5Check installed accessories are straight and square in the required locations and within acceptable tolerances
- 2.6Terminate lighting circuits to luminaires, switches and other control devices in accordance with manufacturer specifications and regulatory requirements
- 2.7Test luminaires and ancillary equipment to ensure compliance
3 Troubleshoot luminaires and ancillary equipment
- 3.1Identify the fault and resulting safety hazards and implement risk control measures in consultation with appropriate personnel
- 3.2Apply diagnostic techniques to troubleshoot luminaires, ancillary equipment and associated lighting circuits using appropriate test equipment
- 3.3Repair/replace faulty circuits/components according to manufacturer specifications and regulatory requirements
- 3.4Test repaired/replaced circuit/component for functionality in accordance with regulatory requirements
- 3.5Dispose of discharge lamps in accordance with environmental guidelines and procedures
- 3.6Document installation and troubleshooting of luminaires, ancillary equipment and associated circuits in accordance with SOPs
Performance evidence
- following work instructions, standard operating procedures (SOPs) and safe work practices
- identifying and interpreting circuits, drawings, specifications and plans relevant to the work to be undertaken
- determining the electrical and non-electrical isolation requirements to prevent the creation of hazards linked from the loss of machine/system/process control according to established procedures
- using lock out tag procedures with appropriate tags/signs
- proving electrical isolation and following established safety rules prior to working on electrical equipment or wiring
- ensuring all electrical equipment and tools are tested and tagged and up to date
- installing accessories ensuring that they are straight and square in the required location
- using safe working practices and take additional care when working with lights that operate at high voltage or contain capacitors
- terminating two (2) or more of the following lighting circuits:
- single light controlled by a single switch
- multiple lights controlled by a single switch
- two and three-way switching using:
- loop at the light method
- loop at the switch method
- complying with the Australian/New Zealand Wiring Rules requirements for the installation and termination of lighting equipment and accessories, including related hazards and safety requirements including maintaining fire integrity
- measuring and recording illumination for comparison against lighting standard AS/NZS 1680.1:2006 Interior and workplace lighting – General principles and recommendations, using a suitable light meter
- locating and repairing faults in luminaires and ancillary equipment
- troubleshooting and repairing faults in common lighting circuits
- replacing lamps with ‘like for like’
- performing periodic servicing of emergency lighting and smoke detector systems and recording intervals of servicing, including remedial action taken
- disposing of discharge lamps according to environmental guidelines and established procedures
- documenting installation and troubleshooting, including remedial action taken in accordance with SOPs.
Knowledge evidence
- safe work practices and procedures and use of personal protective equipment (PPE)
- lighting applications, including:
- basic principles, terminology and units in describing process and concepts of illumination
- the major design requirements of luminaires regarding reflection or diffusion of light and direct the light onto the working place
- functional category types of luminaires:
- direct with 90-100% downward light component
- indirect with 90-100% upward light component
- general diffusing with approximately equal upward and downward components
- semi direct with 10-40% upward and 60-90% downward
- semi direct with 60-90% upward and 10-40% downward
- maintenance of luminaires, including lamp replacement and cleaning
- common faults in luminaires
- disposal of discharge lamps in accordance with environmental guidelines and established procedures
- elementary lighting design, including:
- requirements to clearly show up the task or work area
- recommended maintenance luminance
- the advantages of the use of reflectors and diffusers
- determining illuminance on a working plane using the ‘point by point’ method and lumen method
- the use of a lux meter to determine lighting and illumination requirements
- emergency evacuation lighting in buildings, including:
- escape and standby lighting
- installation requirements of emergency lighting luminaires
- installation of smoke detection in domestic and residential premises
- inspection and maintenance of emergency lighting and smoke detectors
- recording requirements
- light sources, including:
- lamp type and their characteristics
- the operating principles of various types of lamps and luminaries and the purpose of their auxiliary control equipment
- energy efficiency
- the cause of low power factor and the measures used to improve power factor in discharge lighting
- Australian/New Zealand Wiring Rules requirements for the installation of lighting equipment and accessories, including related hazards and safety requirements
- application of various types of lamps and luminaires
- ‘stroboscopic effect’ and the methods used to overcome, including:
- ‘non-stroboscopic’ circuit (inclusion of a capacitor in one fluorescent lamp circuit to provide phase shift in relation to the other lamp circuit)
- connecting adjacent lamps to different phases in large installations
- electronic lamp circuits operating at high frequencies
- lighting circuits, including:
- single light controlled by a single switch
- multiple lights controlled by a single switch
- two and three-way switching using the loop at the light method and the loop at the switch method
- lighting control, including:
- manual control involving the use of two-way and intermediate switches
- time switches both analogue and digital for programmed control
- time delay switches that are adjustable and may be air-valve or electronic type
- photo-sensitive electronic control used to control outdoor and street lighting
- passive infrared (PIR) technology used in scanning devices to detect movement of a hot or cold body and automatically switch on security or convenience lighting
- various types light dimmers, including electronic
- lighting management systems, e.g. C-Bus.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing MEM10024
What does an assessment tool for MEM10024 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MEM10024 needs to address all 87 unit components: 3 elements with 17 performance criteria, 22 performance evidence requirements, 48 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for MEM10024?
Auditori pulls the current release of MEM10024 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MEM10024 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing MEM10024 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MEM10024, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- MEM03001 — Perform manual production assembly
- MEM03002 — Perform precision assembly
- MEM03003 — Perform sheet and plate assembly
- MEM03004 — Perform electronic/electrical assembly (production)
- MEM03005 — Rework and repair (electrical/electronic production)
- MEM03006 — Set assembly stations
- MEM04001 — Operate melting furnaces
- MEM04002 — Perform gravity die casting
- MEM04003 — Operate pressure die casting machine
- MEM04004 — Prepare and mix sand for metal moulding
- MEM04006 — Operate sand moulding and core making machines
- MEM04007 — Pour molten metal
Your MEM10024 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate MEM10024 free