MEM10007Modify control systems

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for MEM10007 must cover

45 assessable components: 5 elements (15 performance criteria), 8 performance evidence and 22 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Determine job requirements

  • 1.1Follow standard operating procedures (SOPs)
  • 1.2Comply with work health and safety (WHS) requirements at all times
  • 1.3Use appropriate personal protective equipment (PPE) in accordance with SOPs
  • 1.4Identify job requirements from specifications, drawings, job sheets or work instructions

2 Plan commissioning procedure

  • 2.1Determine control system format and understand operational intent
  • 2.2Sequence commissioning procedures effectively to meet requirement of components and control application

3 Check control system installation

  • 3.1Verify correct installation of system components against specifications
  • 3.2Ensure appropriate test equipment is functional and calibrated before use
  • 3.3Ensure components or control loop/system is powered up and checked for correct supply in accordance with specifications
  • 3.4Ensure all readings/measurements are obtained, interpreted and recorded

4 Adjust control system and assess performance

  • 4.1Adjust control loop/system components to meet control characteristics, application and process specifications utilising appropriate techniques
  • 4.2Make final verifications including any operational adjustments to ensure required performance

5 Commission modifications

  • 5.1Ensure necessary modifications to change performance in order to meet manufacturers’ or operational specifications or safety and legislative requirements are undertaken or actioned
  • 5.2Provide reports on system/process characteristics for warranty, handover and legislative purposes
  • 5.3Document all modifications and record result according to SOPs

Performance evidence

  • following work instructions, standard operating procedures (SOPs) and safe work practices
  • identifying and interpreting specifications and drawings for determining control system to meet specifications and control application
  • planning commissioning procedure involving the development of a commissioning procedure, testing of operation and adjustment to conform to specification
  • verifying control system components, including all instruments and devices which make up or control a loop/system against specifications
  • using appropriate test equipment to check control system installation in accordance with specifications in a safe and effective manner
  • adjusting control loop/system components and making final verifications to ensure required performance of control application
  • making modifications to change performance to meet specifications and safety and legislative requirements
  • providing reports where required and documenting all modifications in accordance with SOPs.

Knowledge evidence

  • safe work practices and procedures and use of personal protective equipment (PPE)
  • control system format
  • operational intent of the processes being controlled by the control system
  • specifications of the control system and the processes being controlled
  • regulatory and legislative requirements associated with the commissioning procedure
  • procedures for commissioning the control system
  • procedures for ensuring that control characteristics, application and process specifications are achieved
  • components of the operational processes
  • installation specifications for each component of the operational processes
  • measuring techniques and equipment appropriate to the measurements to be taken
  • test equipment and techniques appropriate to the commissioning of the control
  • calibration procedures for the selected test equipment
  • procedures for energising components and/or the control loop/system
  • supply requirements of components and the control loop/system
  • recording requirements for readings/measurements taken
  • adjustments that can be made to the control loop/system components and effects of adjustments on the control characteristics and operational processes
  • measurements/tests to be undertaken to verify control system and process operation and reasons for selecting the chosen measurements/tests
  • procedures to be followed if the operational specifications of the control system and/or process cannot be achieved
  • effect of changes to control system components on system performance
  • appropriate authority to approve any modifications
  • reporting requirements associated with the commissioning of control systems
  • requirements and reasons for recording modifications.

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing MEM10007

What does an assessment tool for MEM10007 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MEM10007 needs to address all 45 unit components: 5 elements with 15 performance criteria, 8 performance evidence requirements, 22 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for MEM10007?

Auditori pulls the current release of MEM10007 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MEM10007 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing MEM10007 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MEM10007, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your MEM10007 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate MEM10007 free