HLTANA012 — Maintain quality and supply of anaesthetic equipment and consumables
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for HLTANA012 must cover
81 assessable components: 5 elements (23 performance criteria), 5 performance evidence and 53 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Check functioning and conduct routine maintenance.
- 1.1Check availability of minimum equipment requirements as per Australia New Zealand College of Anaesthetists (ANZCA) policy guidelines.
- 1.2Perform safety checks.
- 1.3Ensure anaesthetic equipment is functioning correctly and rectify any routine problems.
- 1.4Clean and safely store equipment.
- 1.5Report hazardous, damaged or faulty equipment and arrange repairs.
- 1.6Disassemble and decontaminate anaesthetic equipment.
- 1.7Dispose of disposable or single use items in accordance with organisational policies and procedures.
2 Maintain adequate stock levels of anaesthetic consumable items.
- 2.1Access and interpret stock documentation, store and rotate stock, check stock levels and take action to maintain supply.
- 2.2Communicate unavailability of stock to relevant personnel.
- 2.3Identify when to withdraw and dispose of stock in compliance with health hazard notices and environmental protection authority.
- 2.4Dispose of expired stock safely in accordance with legislative requirements and organisational policies and procedures.
- 2.5Ensure product disclosure information, technical data sheets and material safety data sheets are available and referenced as required.
- 2.6Identify suitable alternative product(s) and access if required.
3 Implement planned maintenance.
- 3.1Identify maintenance procedures and appropriate documentation.
- 3.2Maintain anaesthetic and monitoring equipment in accordance with manufacturers’ guidelines.
- 3.3Complete regular servicing in accordance with scope of own role.
- 3.4Complete accurate maintenance documentation and escalate to relevant personnel any issue.
- 3.5Review maintenance records and update.
4 Arrange repairs of anaesthetic equipment.
- 4.1Identify anaesthetic equipment faults and place safety hazard label on anaesthetic equipment.
- 4.2Complete repair request documentation and give to relevant personnel for actioning.
- 4.3Complete routine and minor anaesthetic equipment repairs.
5 Orientate staff to anaesthetic and monitoring equipment.
- 5.1Provide instruction on anaesthetic equipment to other members of the multidisciplinary team.
- 5.2Provide in-service training on anaesthetic equipment to other members of the multidisciplinary team.
Performance evidence
- follow legislation, industry standards and code of practice, manufacturers’ guidelines and organisational policies and procedures to maintain the standard and supply of anaesthetic equipment and supplies for at least one facility, including:
- routine cleaning and care
- arranging repairs
- testing for functionality and safety, including ANZCA level 2 and level 3 check of the anaesthetic machine
- equipment decontamination.
Knowledge evidence
- national, state or territory legal and ethical considerations for management of equipment and consumables, and how these are applied in organisations:
- codes of practice
- duty of care
- infection prevention and control
- records management
- rights and responsibilities of workers and employers
- work role boundaries including responsibilities and limitations
- work health and safety (WHS):
- electrical safety requirements for equipment
- gas safety
- laser safety
- radiation safety
- types of anaesthetic equipment and consumables required:
- medications, forms and other consumables
- anaesthetic airway, breathing, infusion monitoring devices
- emergency equipment
- scavenge systems
- non-disposable equipment
- operating room air change and pollution standards
- areas that require anaesthesia related equipment and consumables:
- anaesthetic and emergency trolleys
- induction room and storerooms
- anaesthetic machines
- procedures for set-up and safety checks, principles and limitation of operation, features, functions and safe use of anaesthetic and monitoring equipment, including their service schedule, storage, disassembly and cleaning requirements, including:
- anaesthetic machine and components, including:
- alarms and measurement devices
- suction and scavenge systems
- ventilator
- bulk and local gas supply equipment including pipeline and cylinders
- vaporisers
- breathing systems, circuits and attachments
- airway and breathing equipment including:
- fibreoptic, video and other intubation adjuncts
- consumables
- breathing circuits and portable ventilators
- invasive and non-invasive monitoring equipment
- emergency equipment
- associated anaesthetic equipment:
- thermoregulation equipment
- infusion and rapid infusion equipment
- anti-thromboembolic device
- ultrasound
- routine problems that occur with different types of equipment and how to rectify within scope of own role
- principles of physics and measurement as it relates to anaesthetic practice, including:
- thermodynamics
- gas laws
- fluid dynamics
- potentiometry
- optics
- transducers
- vaporisation
- ultrasound
- basic electronic components and their function.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing HLTANA012
What does an assessment tool for HLTANA012 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for HLTANA012 needs to address all 81 unit components: 5 elements with 23 performance criteria, 5 performance evidence requirements, 53 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for HLTANA012?
Auditori pulls the current release of HLTANA012 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for HLTANA012 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing HLTANA012 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of HLTANA012, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- HLTANA008 — Prepare patients for anaesthesia
- HLTANA009 — Monitor patients during anaesthesia
- HLTANA010 — Assist with airway management
- HLTANA011 — Respond to anaesthesia related emergencies
- HLTANA013 — Assist with clinical procedures used in anaesthesia
- HLTANA014 — Monitor medications in the anaesthetic environment
Your HLTANA012 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate HLTANA012 free