What an assessment for UEPMNT404 must cover

76 assessable components: 5 elements (28 performance criteria), 26 performance evidence and 22 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Plan and prepare for work

  • 1.1Requirements including scope of work and assigning roles are identified and confirmed with appropriate personnel or by site inspection, in accordance with workplace procedures
  • 1.2Work, Health and Safety (WHS)/Occupational Health and Safety (OHS) regulations, legislative requirements, industry standards, codes of practice, manufacturer specifications, environmental obligations and workplace procedures are reviewed in preparation for work
  • 1.3Resources are obtained and inspected for compliance with job specification
  • 1.4Relevant plans, drawings and manuals are selected and used, in accordance with workplace procedures
  • 1.5Correct materials and components for work are obtained and inspected, in accordance with workplace procedures, for compliance with job specification
  • 1.6Work is planned, sequenced and prioritised, in accordance with workplace procedures
  • 1.7Potential hazards are identified and risk control measures are selected and implemented, in accordance with workplace procedures
  • 1.8Work area is prepared, in accordance with workplace procedures

2 Remove complex mechanical pumps for maintenance

  • 2.1Isolations for work are confirmed, in accordance with workplace procedures
  • 2.2Complex mechanical pump is disconnected, in accordance with workplace procedures
  • 2.3Complex mechanical pump is removed, in accordance with workplace procedures
  • 2.4Complex mechanical pump is inspected for abnormalities, in accordance with workplace procedures

3 Maintain complex mechanical pumps

  • 3.1Maintenance is performed on complex mechanical pump, in accordance with workplace procedures and manufacturers’ specifications
  • 3.2Complex mechanical pump is dismantled for maintenance, in accordance with workplace procedures and manufacturers’ specifications
  • 3.3Sketches are made, data noted and components marked for identification or reassembly, in accordance with workplace procedures
  • 3.4New components are inspected, in accordance with workplace procedures, for compliance with manufacturers’ specifications
  • 3.5Dimensional inspection is performed with precision measuring devices, in accordance with workplace procedures, to ensure compliance with manufactures’ specifications and results are recorded
  • 3.6Complex mechanical pump is reassembled, using industry principles and approved techniques, in accordance with workplace procedures and manufacturers’ specifications
  • 3.7Modifications or alterations are undertaken, in accordance with workplace procedures

4 Replace or install complex mechanical pumps

  • 4.1Equipment and plant is prepared for complex mechanical pump replacement, in accordance with workplace procedures
  • 4.2Complex mechanical pump is replaced, in accordance with workplace procedures and manufacturers’ specifications
  • 4.3Complex mechanical pump is levelled, aligned, coupled and connected, in accordance with workplace procedures
  • 4.4All fastenings are torqued, in accordance with workplace procedures and manufacturers’ specifications
  • 4.5Machinery, plant and pump are given a test run, then monitored and adjusted, as required, in accordance with workplace procedures and manufacturers’ specifications

5 Complete work

  • 5.1Work is completed and appropriate personnel are notified, in accordance with workplace procedures
  • 5.2Work area is cleared of waste, cleaned, restored and secured, in accordance with workplace procedures
  • 5.3Tools and equipment are cleaned, maintained and stored, in accordance with workplace procedures
  • 5.4Work completion details are finalised, in accordance with workplace procedures

Performance evidence

  • analysing using data analysis techniques
  • applying Work, Health and Safety(WHS)/Occupational Health and Safety (OHS) requirements including:
  • emergency procedures
  • hazard identification
  • risk control measures
  • safe working practices
  • communicating with personnel
  • completing work as per scheduled requirements
  • determining permit to work requirements
  • dismantling and reassembling techniques for maintaining complex mechanical valves
  • implementing legislation, industry standards, codes of practice and regulations
  • interpreting manufacturers’ specifications and manuals
  • levelling and aligning with approved techniques
  • maintaining complex mechanical pumps using maintenance techniques and procedures
  • operating with torque techniques
  • planning for maintenance of complex mechanical pump work
  • reading technical drawings and data
  • recognising worn or damaged components
  • removing complex mechanical pumps for maintenance using removal techniques
  • replacing or installing complex mechanical pumps using installation techniques and procedures
  • selecting materials and components
  • testing using diagnostic and testing techniques
  • undertaking isolations and torqueing
  • using tools
  • utilising precision measuring equipment
  • working with and applying fluid dynamics principles

Knowledge evidence

  • analysis and data recording techniques
  • diagnostic and testing techniques
  • fluid dynamics
  • isolations
  • legislation, industry standards, codes of practice and regulations
  • level and alignment techniques
  • maintenance of complex mechanical pumps generation plant and equipment, its location and operation
  • manufacturers’ specifications and manuals
  • materials and components of pumps
  • permit to work system
  • precision measuring equipment
  • technical drawings and data
  • tools
  • torque techniques
  • typical arrangements of power production plant
  • WHS/OHS legislated requirements including:
  • emergency procedures
  • risk control measures
  • hazard identification
  • safe working practices
  • workplace documentation
  • workplace policies and procedures

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEPMNT404

What does an assessment tool for UEPMNT404 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEPMNT404 needs to address all 76 unit components: 5 elements with 28 performance criteria, 26 performance evidence requirements, 22 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEPMNT404?

Auditori pulls the current release of UEPMNT404 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEPMNT404 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEPMNT404 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEPMNT404, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEPMNT404 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEPMNT404 free