UEPMNT368 — Repair and maintain stationary gas fuelled reciprocating engines
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEPMNT368 must cover
49 assessable components: 3 elements (26 performance criteria), 10 performance evidence and 13 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to repair and maintain gas fuelled reciprocating engines
- 1.1Work, Health and Safety (WHS)/Occupational Health and Safety (OHS) procedures are identified and implemented, in accordance with workplace procedures
- 1.2Health and safety risks are identified and risk control measures are followed, in accordance with workplace procedures
- 1.3Safety hazards that have not previously been identified are noted, and risk control measures are implemented and followed, in accordance with workplace procedures
- 1.4Formal authority to proceed with repair and maintenance work is obtained, in accordance with workplace procedures
- 1.5Repair and maintenance work is sequenced, in accordance with workplace procedures
- 1.6Nature and location of repair and maintenance work is determined from documentation, or appropriate personnel, to establish scope of work and assigned roles
- 1.7Stationary gas fuelled reciprocating engine plant, equipment and component specifications and manufacturers’ manuals are obtained
- 1.8Material needed for repair and maintenance work is obtained, in accordance with workplace procedures and is checked against job requirements
- 1.9Tools and equipment, including personal protective equipment and testing devices are obtained, in accordance with workplace procedures and are checked for correct operation and safety
2 Repair and maintain gas fuelled reciprocating engines
- 2.1Regulatory and code of practice recording and reporting requirements are completed, in accordance with workplace procedures
- 2.2Gas and electrical circuits, machines and/or power generation plant are checked prior to commencement and are recorded as being isolated and safe, in accordance with workplace procedures
- 2.3Nature and possible cause of stationary gas fuelled reciprocating engine faults, or out of specification performance, are identified from defect reports or operational records
- 2.4Fault finding using observation, measurement, calculations, comparison with normal system and component parameter values is undertaken
- 2.5Faults beyond the scope of gas fuel train, ignition or fume exhaust work are identified and arrangements are made for authorised personnel to rectify faults
- 2.6Stationary gas fuelled reciprocating engine is disconnected, to carry out maintenance and repairs, in accordance with workplace procedures
- 2.7Components are removed or dismantled, where necessary, and parts are stored to protect them against loss or damage
- 2.8Faulty components are rechecked and their fault status is reconfirmed
- 2.9Materials required to rectify faults are obtained, in accordance with workplace procedures
- 2.10Repair and maintenance work is carried out without waste of materials or damage to apparatus, circuits, the surrounding environment or services, in accordance with workplace procedures and sustainable energy principles and practices
- 2.11Stationary gas fuelled reciprocating engine repair is tested, in accordance with workplace procedures
- 2.12Stationary gas fuelled reciprocating engine is reassembled, reconnected and tested to ensure it is operating safely and that it complies with relevant workplace and legislative requirements
3 Complete and report on repair and maintenance
- 3.1Final check of stationary gas fuelled reciprocating engine is made to verify compliance with legislative and certification requirements
- 3.2Work area is cleared and materials are disposed of or recycled, in accordance with workplace procedures
- 3.3Tools and equipment are cleaned, checked, serviced and stored, in accordance with manufacturers’ recommendations and workplace procedures
- 3.4Work site is cleaned and made safe, in accordance with workplace procedures
- 3.5Maintenance and repair work is documented and appropriate personnel are notified, in accordance with workplace procedures
Performance evidence
- applying Work, Health and Safety (WHS)/Occupational Health and Safety (OHS) requirements including: emergency procedures, hazard identification, risk control measures
- communicating with personnel
- determining permit to work requirements
- disconnecting and reconnecting stationary gas fuelled reciprocating engine
- finding and rectifying faults
- preparing to repair and maintain stationary gas fuelled reciprocating engines
- repairing and maintaining stationary gas fuelled reciprocating engines including identifying faults completing and reporting on repair and maintenance work
- safe working practices implementing legislation, industry standards, codes of practice and regulations
- using manufacturers’ specifications and manuals
- working with sustainable energy principles and practices
Knowledge evidence
- documentation and report requirements
- fault finding
- gas fuelled reciprocating engines
- gas fuels
- legislation, industry standards, codes of practice and regulations
- manufacturers’ specifications and manuals
- permit to work system
- reconnection and disconnection of stationary gas fuelled reciprocating engines
- stationary gas fuelled reciprocating engine repair and maintenance
- sustainable energy principles and practices
- WHS/OHS legislated requirements including: emergency procedures, hazard identification, risk control measures, safe working practices
- workplace documentation
- workplace policies and procedures
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEPMNT368
What does an assessment tool for UEPMNT368 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEPMNT368 needs to address all 49 unit components: 3 elements with 26 performance criteria, 10 performance evidence requirements, 13 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEPMNT368?
Auditori pulls the current release of UEPMNT368 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEPMNT368 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEPMNT368 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEPMNT368, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEPMNT001 — Carry out routine work activities in an electricity supply industry generation environment
- UEPMNT002 — Carry out routine work activities in an ESI large scale wind generation environment
- UEPMNT003 — Coordinate maintenance on a wind farm
- UEPMNT004 — Diagnose and repair faults in large scale wind turbines
- UEPMNT005 — Diagnose and repair faults in wind turbine control systems
- UEPMNT006 — Diagnose and repair faults in wind turbine electrical systems
- UEPMNT007 — Diagnose and repair mechanical systems faults in wind turbines
- UEPMNT008 — Maintain and monitor wind farm civil assets
- UEPMNT009 — Maintain large scale wind turbines
- UEPMNT010 — Maintain wind turbine control systems
- UEPMNT011 — Maintain wind turbine electrical systems
- UEPMNT012 — Maintain wind turbine mechanical systems
Your UEPMNT368 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEPMNT368 free