UEPMNT304 — Maintain mechanical pumps
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEPMNT304 must cover
73 assessable components: 5 elements (28 performance criteria), 23 performance evidence and 22 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Plan and prepare for work
- 1.1Requirements including scope of work and assigned roles are identified and confirmed with appropriate personnel or by site inspection, in accordance with workplace procedures
- 1.2Work, Health and Safety (WHS)/Occupational Health and Safety (OHS) regulations, legislative requirements, industry standards, codes of practice, manufacturers’ specifications, environmental obligations and workplace procedures are reviewed in preparation for work
- 1.3Resources are obtained and inspected for compliance with job specification
- 1.4Relevant plans, drawings and manuals are selected and used, in accordance with workplace procedures
- 1.5Correct materials and components for work are obtained and inspected, in accordance with workplace procedures, for compliance with job specification
- 1.6Work is planned, sequenced and prioritised, in accordance with workplace procedures
- 1.7Potential hazards are identified and risk control measures are selected and implemented, in accordance with workplace procedures
- 1.8Work area is prepared, in accordance with workplace procedures
2 Remove mechanical pumps for maintenance
- 2.1Isolations are confirmed, where appropriate, in accordance with workplace procedures and site requirements
- 2.2Mechanical pump is disconnected, in accordance with the workplace procedures
- 2.3Mechanical pump is removed, in a manner which will assist in replacement, in accordance with workplace procedures
- 2.4Mechanical pump is inspected for abnormalities, in accordance with workplace procedures
3 Maintain mechanical pumps
- 3.1Maintenance is performed, in accordance with manufacturers’ specification and workplace procedures
- 3.2Mechanical pump is dismantled, in accordance with manufacturers’ specification and workplace procedures
- 3.3Sketches are made, data is noted and components are marked for identification or reassembly, in accordance with workplace procedures
- 3.4New components are inspected for compliance, in accordance with workplace procedures and manufacturers’ specifications
- 3.5Dimensional inspection is performed, with precision measuring devices, in accordance with workplace procedures, to ensure compliance with manufacturers’ specifications and results are recorded
- 3.6Mechanical pump is reassembled, applying appropriate principles and techniques, in accordance with workplace procedures and manufacturers’ specifications
- 3.7Modifications and/or alterations to mechanical pump are undertaken, in accordance with workplace procedures
4 Replace or install mechanical pumps
- 4.1Equipment is prepared for pump replacement, in accordance with workplace procedures
- 4.2Mechanical pump is replaced, in accordance with workplace procedures and manufacturers’ specification
- 4.3Mechanical pump is levelled, aligned, coupled and connected, in accordance with workplace procedures
- 4.4All fastenings are torqued, in accordance with workplace procedures and manufacturers’ specifications
- 4.5Machinery and/or plant, including mechanical pump, are given a test run, and are monitored and adjusted, as required, in accordance with workplace procedures and manufacturers’ specifications
5 Complete work
- 5.1Work is completed, and appropriate personnel are notified, in accordance with workplace procedures
- 5.2Work area is cleared of waste, cleaned, restored and secured, in accordance with workplace procedures
- 5.3Tools and equipment are maintained and stored, in accordance with workplace procedures
- 5.4Work completion details are finalised, in accordance with workplace procedures
Performance evidence
- applying Work, Health and Safety (WHS)/Occupational Health and Safety (OHS) requirements including:
- emergency procedures
- hazard identification
- risk control measures
- safe working practices
- applying coupling levelling and alignment techniques
- communicating with personnel
- completing work in line with schedules
- determining data analysis techniques and tools
- dismantling and reassembling techniques
- identifying resources and materials
- implementing legislation, industry standards, codes of practice and regulations
- interpreting technical drawings, manufactures’ specifications and manuals
- manufacturing and installing seals and gaskets
- recognising worn or damaged components
- removing and maintaining mechanical pumps
- replacing or installing mechanical pumps
- selecting materials and components
- using precision measuring equipment
- using removal and maintenance techniques and procedures
- using tools including specialised tools and jigs
- utilising permit to work system
- working with defined tolerances
Knowledge evidence
- data analysis techniques and tools
- defined tolerances
- dismantle and reassemble techniques
- legislation, industry standards, codes of practice and regulations
- maintenance of mechanical pumps
- manufacture and installation of seals and gaskets
- manufacturers’ specifications and manuals
- materials and components
- permit to work system
- precision measuring equipment
- resources and materials
- technical drawings
- techniques for coupling, levelling and alignment
- tools including specialised tools and jigs
- WHS/OHS legislated requirements including:
- emergency procedures
- hazard identification
- risk control measures
- safe working practices
- workplace documentation,
- workplace policies and procedures
- worn or damaged components
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEPMNT304
What does an assessment tool for UEPMNT304 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEPMNT304 needs to address all 73 unit components: 5 elements with 28 performance criteria, 23 performance evidence requirements, 22 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEPMNT304?
Auditori pulls the current release of UEPMNT304 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEPMNT304 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEPMNT304 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEPMNT304, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEPMNT001 — Carry out routine work activities in an electricity supply industry generation environment
- UEPMNT002 — Carry out routine work activities in an ESI large scale wind generation environment
- UEPMNT003 — Coordinate maintenance on a wind farm
- UEPMNT004 — Diagnose and repair faults in large scale wind turbines
- UEPMNT005 — Diagnose and repair faults in wind turbine control systems
- UEPMNT006 — Diagnose and repair faults in wind turbine electrical systems
- UEPMNT007 — Diagnose and repair mechanical systems faults in wind turbines
- UEPMNT008 — Maintain and monitor wind farm civil assets
- UEPMNT009 — Maintain large scale wind turbines
- UEPMNT010 — Maintain wind turbine control systems
- UEPMNT011 — Maintain wind turbine electrical systems
- UEPMNT012 — Maintain wind turbine mechanical systems
Your UEPMNT304 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEPMNT304 free