UEERA0089 — Service refrigeration appliances
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEERA0089 must cover
53 assessable components: 3 elements (19 performance criteria), 17 performance evidence and 17 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to service refrigerated appliance
- 1.1WHS/OHS hazards, risk control methods, relevant standards, codes and legislation are obtained and applied in accordance with workplace procedures
- 1.2Extent of work to be completed is determined from service and fault requests and/or discussions with supervisor/appropriate person/s in accordance with workplace procedures
- 1.3Advice is sought, as required, from supervisor to ensure work is coordinated with others
- 1.4Sources of materials and parts required for work are identified in accordance with workplace procedures
- 1.5Tools, equipment and testing devices to locate faults are obtained in accordance with workplace procedures and checked for operational safety
2 Service refrigerated appliance
- 2.1Need to test or measure live electrical work is determined in accordance with workplace procedures and WHS/OHS requirements
- 2.2Appliance is checked as being isolated, where necessary, in accordance with workplace procedures and WHS/OHS requirements
- 2.3Safety hazards resulting from defect or fault are identified and documented, and risk control measures are implemented in accordance with workplace procedures and in consultation with appropriate person/s
- 2.4Appliances are tested and components are inspected for wear or defects in accordance with workplace procedures, manufacturer specifications and industry codes of practice
- 2.5Appliance faults, and their cause, are identified using measured and calculated values of appliance parameters in accordance with workplace procedures
- 2.6Appliance is dismantled, where necessary, and parts are safely stored to protect them against loss or damage in accordance with workplace procedures
- 2.7Defective, worn or faulty appliance components are rechecked and their status is confirmed
- 2.8Replacement parts to rectify defects/faults are obtained in accordance with workplace procedures
- 2.9Effectiveness of repair work is tested in accordance with workplace procedures
- 2.10Appliance is reassembled, given a final test and prepared for return to service in accordance with workplace procedures
- 2.11Unexpected situations are resolved in accordance with workplace procedures, safety guidelines and with the approval of an authorised person/supervisor
- 2.12Servicing of refrigerated appliance is completed without damage to apparatus, circuits, the surrounding environment and/or services using relevant sustainable energy practices in accordance with workplace procedures
3 Complete and report fault-finding and repair activities
- 3.1Work area is cleaned and made safe in accordance with workplace procedures
- 3.2Service report is completed and verified by an appropriate person/supervisor in accordance with workplace procedures
Performance evidence
- applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including:
- applying safe working practices
- identifying hazards
- using risk control measures
- completing and reporting fault-finding and repair activities
- implementing legalisation, industry standards, codes of practice and regulations
- preparing to service refrigerated appliance
- servicing refrigerated appliances, including:
- completing service report
- dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
- determining work from service request
- finding faults
- flammable and non-flammable refrigerants
- identifying defective components affecting appliance
- rectifying defects or faults
- testing appliance functions
- using manufacturer specifications and manuals.
Knowledge evidence
- flammable and non-flammable refrigerants
- service appliance refrigeration systems, including:
- appliance refrigeration systems
- capillary systems
- major electrical refrigeration appliances, including refrigerators and freezers
- operational principles of major domestic appliances that use electrical, gas and/or water services that incorporate refrigeration
- operational testing and set-up procedures
- retrofitting of domestic refrigeration systems
- relevant legislation, industry standards, codes of practice and regulations
- relevant manufacturer specifications
- relevant risk mitigation processes, including:
- potential hazards
- risk control measures
- safe working practices
- relevant WHS/OHS legislated requirements
- relevant workplace documentation
- relevant workplace policies and procedures.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEERA0089
What does an assessment tool for UEERA0089 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERA0089 needs to address all 53 unit components: 3 elements with 19 performance criteria, 17 performance evidence requirements, 17 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEERA0089?
Auditori pulls the current release of UEERA0089 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERA0089 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEERA0089 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERA0089, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEERA0001 — Analyse the operation of HVAC air and hydronic systems
- UEERA0002 — Analyse the psychrometric performance of HVAC/R systems
- UEERA0003 — Analyse the thermodynamic performance of HVAC/R systems
- UEERA0004 — Analyse vibration and noise in refrigeration and air conditioning systems
- UEERA0005 — Apply safety awareness and legal requirements for ammonia refrigerant
- UEERA0006 — Apply safety awareness and legal requirements for carbon dioxide refrigerant
- UEERA0007 — Apply safety awareness and legal requirements for flammable refrigerants
- UEERA0008 — Audit HVAC/R control systems for compliance with regulations and standards
- UEERA0009 — Audit energy use for commercial HVAC/R systems
- UEERA0010 — Commission complex heating, ventilation and air conditioning (HVAC) systems
- UEERA0011 — Commission complex refrigeration systems and equipment
- UEERA0012 — Commission complex refrigeration/air conditioning control systems
Your UEERA0089 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEERA0089 free