UEERA0084 — Service and repair self-contained flammable refrigerants air conditioning and refrigeration systems
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEERA0084 must cover
50 assessable components: 3 elements (21 performance criteria), 13 performance evidence and 16 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to service and repair flammable refrigerants refrigeration and air conditioning systems
- 1.1WHS/OHS hazards, risk control methods, relevant standards, codes and legislation are obtained and applied
- 1.2Hazards not previously identified are reported and advice on risk control measures sought from supervisor
- 1.3Details of the work are obtained from documentation and/or from supervisor to determine the scope of work to be completed
- 1.4Advice is sought from supervisor, as required, to ensure work is coordinated effectively with others
- 1.5Materials required for the work are identified and obtained in accordance with workplace procedures
- 1.6Tools, equipment and testing devices required for the work are obtained and checked for correct operation and safety in accordance with workplace procedures
2 Repair and service flammable refrigerants refrigeration and air conditioning systems
- 2.1Measuring system operating parameters are conducted in accordance with WHS/OHS requirements and workplace safety procedures
- 2.2Checks are conducted to ensure system/component parts are isolated, as required, in accordance with workplace procedures and WHS/OHS requirements
- 2.3Refrigerant is removed from system safely in accordance with relevant legislation, standards and code requirements, manufacturer instructions and workplace procedures
- 2.4Pressure testing is conducted and precautions taken to prevent damage to components in accordance with workplace procedures and WHS/OHS requirements
- 2.5Pressure testing is conducted at a pressure compatible with flammable refrigerants in accordance with industry standards and WHS/OHS requirements
- 2.6System leaks are located and rectified using testing methods appropriate to the system in accordance with industry standards and workplace procedures
- 2.7System is evacuated for an operational flammable refrigerant system in accordance with relevant industry standards and workplace procedures
- 2.8System is charged safely with flammable refrigerants and compatible lubricants in accordance with relevant legislation, standards and code requirements, manufacturer instructions and workplace procedures
- 2.9Actual and specified range of operating conditions are determined from measured and calculated values as they apply to flammable refrigerants vapour compression systems in accordance with workplace procedures and industry standards
- 2.10Methods for dealing unplanned situations are discussed, as required, with relevant person/s for approval and documented in accordance with workplace procedures
- 2.11Operating conditions are determined without damage to apparatus, circuits, the surrounding environment and/ or services using sustainable energy practices
3 Complete and report servicing and repairing flammable refrigerants refrigeration and air conditioning systems
- 3.1Worksite is cleaned and made safe in accordance with workplace procedures
- 3.2Contaminated refrigerant and lubricant are dealt with in accordance with legislative/regulatory and industry standards and requirements
- 3.3Operation conditions are documented and include identification of any parameter that is not within the specified range for the system
- 3.4Work supervisor is notified of work completion in accordance with workplace procedures
Performance evidence
- applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures
- charging the system with the appropriate type and quantity of flammable refrigerants
- completing documentation
- completing work and reporting on servicing and repairing flammable refrigerants refrigeration and air conditioning systems
- conducting pressure testing at the appropriate pressure level and without damaging components
- dealing with unplanned events
- evacuating the system to the required standard and using appropriate vacuum measuring instruments
- locating and rectifying leaks
- obtaining and recording measurements
- preparing to service and repair flammable refrigerants refrigeration and air conditioning systems
- removing and storing refrigerant correctly
- selecting appropriate materials and equipment
- servicing and repairing flammable refrigerants refrigeration and air conditioning systems.
Knowledge evidence
- charging requirements and procedures
- compressor lubricant types, applications and safe handling
- evacuation requirements and procedures
- flammable refrigerant (A2, A2L and A3) types, applications, dangers, safe handling, storage and transport
- flammable refrigerant refrigeration and air conditioning systems, components and operating conditions
- leak detection requirements and procedures
- pressure testing requirements and procedures
- refrigerant removal/recovery and flushing requirements and procedures
- relevant job safety assessments or risk mitigation processes
- relevant legislation, industry standards and codes of practice, including hazards associated with flammable refrigerants
- relevant manufacturer specifications
- relevant WHS/OHS legislated requirements
- relevant workplace documentation
- relevant workplace policies and procedures
- system access tools and procedures
- tube joining tools and procedures.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEERA0084
What does an assessment tool for UEERA0084 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERA0084 needs to address all 50 unit components: 3 elements with 21 performance criteria, 13 performance evidence requirements, 16 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEERA0084?
Auditori pulls the current release of UEERA0084 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERA0084 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEERA0084 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERA0084, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEERA0001 — Analyse the operation of HVAC air and hydronic systems
- UEERA0002 — Analyse the psychrometric performance of HVAC/R systems
- UEERA0003 — Analyse the thermodynamic performance of HVAC/R systems
- UEERA0004 — Analyse vibration and noise in refrigeration and air conditioning systems
- UEERA0005 — Apply safety awareness and legal requirements for ammonia refrigerant
- UEERA0006 — Apply safety awareness and legal requirements for carbon dioxide refrigerant
- UEERA0007 — Apply safety awareness and legal requirements for flammable refrigerants
- UEERA0008 — Audit HVAC/R control systems for compliance with regulations and standards
- UEERA0009 — Audit energy use for commercial HVAC/R systems
- UEERA0010 — Commission complex heating, ventilation and air conditioning (HVAC) systems
- UEERA0011 — Commission complex refrigeration systems and equipment
- UEERA0012 — Commission complex refrigeration/air conditioning control systems
Your UEERA0084 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEERA0084 free