UEERA0063 — Recover, pressure test, evacuate, charge and leak test refrigerants - appliances
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEERA0063 must cover
35 assessable components: 3 elements (22 performance criteria), 5 performance evidence and 8 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to recover refrigerants, pressure and leak test, evacuate and charge refrigeration appliance
- 1.1WHS/OHS hazards, risk control methods, relevant standards, codes and legislation are obtained and applied in accordance with workplace procedures
- 1.2Safety hazards which have not previously been identified are noted and risk control measures implemented in accordance with workplace procedures
- 1.3Extent of work to be completed is determined from documentation and/or discussion with supervisor/appropriate person/s in accordance with workplace procedures
- 1.4Work is sequenced in accordance with job schedule and workplace procedures
- 1.5Appropriate person/s is consulted, as required, to ensure work is coordinated with others
- 1.6Refrigerants, lubricants and cleaning materials are obtained in accordance with workplace procedures
- 1.7Tools, equipment and testing devices are obtained in accordance with workplace procedures and checked for operational safety
2 Recover refrigerants, pressure and leak test, evacuate and charge refrigeration appliance
- 2.1Checks are carried out to ensure system or component parts are isolated, when necessary, in accordance with workplace procedures and WHS/OHS requirements
- 2.2Circuits, machines and plant are checked as being isolated, where necessary, in accordance with workplace procedures and WHS/OHS requirements
- 2.3Refrigerant is removed from appliance safely and is placed into labelled containers in accordance with workplace procedures and regulatory requirements
- 2.4Precautions are taken in accordance with workplace procedures to prevent damage to components while pressure testing appliance
- 2.5Pressure testing is conducted in accordance with workplace procedures using dry nitrogen at a pressure relative to refrigerant used
- 2.6Leaks are located and rectified using testing methods appropriate to the appliance under test in accordance with workplace procedures
- 2.7Appliance is evacuated to required level and is cleaned of all moisture and other contaminates in accordance with workplace procedures
- 2.8A ‘drop test’ is used to test effectiveness of evacuation in accordance with workplace procedures using an appropriate electronic vacuum gauge
- 2.9Components and lubricants are checked and maintained in accordance with workplace procedures and manufacturer specifications
- 2.10Appliance is charged with appropriate refrigerant in accordance with workplace procedures and manufacturer specifications
- 2.11Problematic situations are resolved in accordance with workplace procedures and are referred to a supervisor
- 2.12Appliance is pressure and leak tested, evacuated and charged without waste of materials or damage to apparatus, the surrounding environment and/or services using relevant sustainable energy practices in accordance with workplace procedures
3 Complete and report on refrigerants recovery pressure and leak test and evacuate and charge work
- 3.1Worksite and equipment are cleaned and made safe in accordance with workplace procedures
- 3.2Contaminated refrigerant is dealt with in accordance with workplace procedures and legislative/regulatory requirements
- 3.3Completion of work is documented and an appropriate person/supervisor is notified in accordance with workplace procedures
Performance evidence
- applying legislation, industry standards, codes of practice and regulations
- applying relevant work, health and safety (WHS)/occupational health and safety (OHS) requirements, including: • applying safe working practices • identifying hazards • implementing safe handling procedures • using risk control measures
- completing and reporting on work activities
- preparing to recover refrigerants, pressure and leak test, evacuate and charge refrigeration appliances
- recovering refrigerants, pressure and leak testing, evacuating and charging refrigerant appliance, including: • completing documentation • conducting pressure testing at appropriate pressure level without damaging components • dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment • evacuating system to required level • evacuating system to required standard using vacuum measuring instruments • locating and rectifying leaks • removing and storing refrigerant • using flammable and non-flammable refrigerants • selecting materials and equipment • using manufacturer specifications and manuals
Knowledge evidence
- flammable and non-flammable refrigerants
- recover, pressure and leak test, evacuate and charge refrigerant appliances, including: • refrigerant properties • safe handling practices • refrigeration oil recovery and reclaim procedures • pressure testing • leak detection • evacuation and dehydration • refrigerant and oil charging • system contamination • refrigeration component replacement
- relevant legislation, industry standards, codes of practice and regulations
- relevant manufacturer specifications
- relevant risk mitigation processes, including: • safe working practices • potential hazards • risk control measures
- relevant WHS/OHS legislated requirements
- relevant workplace documentation
- relevant workplace policies and procedures
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEERA0063
What does an assessment tool for UEERA0063 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERA0063 needs to address all 35 unit components: 3 elements with 22 performance criteria, 5 performance evidence requirements, 8 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEERA0063?
Auditori pulls the current release of UEERA0063 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERA0063 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEERA0063 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERA0063, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEERA0001 — Analyse the operation of HVAC air and hydronic systems
- UEERA0002 — Analyse the psychrometric performance of HVAC/R systems
- UEERA0003 — Analyse the thermodynamic performance of HVAC/R systems
- UEERA0004 — Analyse vibration and noise in refrigeration and air conditioning systems
- UEERA0005 — Apply safety awareness and legal requirements for ammonia refrigerant
- UEERA0006 — Apply safety awareness and legal requirements for carbon dioxide refrigerant
- UEERA0007 — Apply safety awareness and legal requirements for flammable refrigerants
- UEERA0008 — Audit HVAC/R control systems for compliance with regulations and standards
- UEERA0009 — Audit energy use for commercial HVAC/R systems
- UEERA0010 — Commission complex heating, ventilation and air conditioning (HVAC) systems
- UEERA0011 — Commission complex refrigeration systems and equipment
- UEERA0012 — Commission complex refrigeration/air conditioning control systems
Your UEERA0063 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEERA0063 free