UEERA0031 — Diagnose and rectify faults in air conditioning and refrigeration control systems
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEERA0031 must cover
34 assessable components: 4 elements (21 performance criteria), 5 performance evidence and 8 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to diagnose and rectify faults
- 1.1WHS/OHS hazards, risk control methods, relevant standards, codes and legislation are obtained and applied in accordance with workplace procedures
- 1.2Details of the air conditioning or refrigeration system fault are obtained from documentation, client and/or from supervisor to establish scope of work to be completed
- 1.3Advice is sought from supervisor, as required, to ensure work is coordinated with others
- 1.4Sources of materials required for work are accessed in accordance with workplace procedures
- 1.5Tools, equipment and testing devices are obtained in accordance with workplace procedures and checked for operational safety
2 Diagnose faults
- 2.1Need to test or measure live electrical work on an operating system is determined in accordance with workplace procedures and WHS/OHS requirements
- 2.2Circuits/machines and/plant are checked as being isolated, where necessary, in accordance with workplace procedures and WHS/OHS requirements
- 2.3Fault finding, using measured and calculated values of system and component parameters, is undertaken methodically in accordance with workplace procedures
- 2.4Faults, beyond the scope of refrigeration and air conditioning system work, are identified and reported in accordance with workplace procedures
- 2.5Control system components are dismantled, where necessary, and parts safely stored to protect them against loss or damage in accordance with workplace procedures
- 2.6Faulty components are rechecked and fault status is confirmed
- 2.7Unexpected situations are resolved in accordance with workplace procedures, safety guidelines and with the approval of an authorised person/supervisor
- 2.8Fault-finding activities are completed without damage to apparatus, circuits, the surrounding environment and/or services using relevant sustainable energy practices in accordance with workplace procedures
3 Repair faults
- 3.1Arrangements are made in accordance with workplace procedures for authorised person/s to rectify faults that are beyond the scope of refrigeration and air conditioning work
- 3.2Equipment is checked as being isolated, where necessary, in accordance with workplace procedures and WHS/OHS requirements
- 3.3Materials required are obtained in accordance with workplace procedures
- 3.4Repairs are completed without damage to other components or apparatus using sustainable energy principles in accordance with workplace procedures
- 3.5Effectiveness of repair work is tested in accordance with workplace procedures
- 3.6Air conditioning and refrigeration control system is reassembled, given a final test and prepared for return to service in accordance with workplace procedures
4 Complete and report fault-finding and rectification activities
- 4.1Work area is cleaned and made safe in accordance with workplace procedures
- 4.2Report is completed in accordance with workplace procedures
Performance evidence
- applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including: applying safe working practices; using risk control measures
- completing and reporting fault-finding and rectification activities
- diagnosing and rectifying faults in refrigeration and air conditioning control systems, including: dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment; finding at least four faults; providing report for rectifications undertaken; rectifying faults without damage; using approved methodical fault-finding techniques
- implementing legislation, industry standards, codes of practice and regulations
- using manufacturer specifications and manuals
Knowledge evidence
- diagnose and rectify faults in refrigeration and air conditioning control systems, including: control systems and components; method and procedures of finding, rectifying and recording control system faults; refrigeration and air conditioning direct digital control applications and basic operation; refrigeration and air conditioning electrical/electronic control types, applications, operation, installation/replacement, setting, adjustment and testing; refrigeration and air conditioning pneumatic control applications and basic operation; refrigeration and air conditioning process characteristics and control parameters; system responses to parameter changes; refrigeration and air conditioning direct digital control applications and basic operation
- relevant legislation, industry standards, codes of practice and regulations
- relevant manufacturer specifications
- relevant risk mitigation processes, including: potential hazards; risk control measures; safe working practices
- relevant WHS/OHS legislated requirements
- relevant workplace documentation
- relevant workplace policies and procedures
- WiFi/router controls for variable air volume (VAV) and remote access controls for refrigeration and air conditioning
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEERA0031
What does an assessment tool for UEERA0031 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERA0031 needs to address all 34 unit components: 4 elements with 21 performance criteria, 5 performance evidence requirements, 8 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEERA0031?
Auditori pulls the current release of UEERA0031 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERA0031 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEERA0031 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERA0031, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEERA0001 — Analyse the operation of HVAC air and hydronic systems
- UEERA0002 — Analyse the psychrometric performance of HVAC/R systems
- UEERA0003 — Analyse the thermodynamic performance of HVAC/R systems
- UEERA0004 — Analyse vibration and noise in refrigeration and air conditioning systems
- UEERA0005 — Apply safety awareness and legal requirements for ammonia refrigerant
- UEERA0006 — Apply safety awareness and legal requirements for carbon dioxide refrigerant
- UEERA0007 — Apply safety awareness and legal requirements for flammable refrigerants
- UEERA0008 — Audit HVAC/R control systems for compliance with regulations and standards
- UEERA0009 — Audit energy use for commercial HVAC/R systems
- UEERA0010 — Commission complex heating, ventilation and air conditioning (HVAC) systems
- UEERA0011 — Commission complex refrigeration systems and equipment
- UEERA0012 — Commission complex refrigeration/air conditioning control systems
Your UEERA0031 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEERA0031 free