UEEIC0039Solve problems in flow measurement components and systems

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UEEIC0039 must cover

95 assessable components: 3 elements (16 performance criteria), 10 performance evidence and 69 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to work on flow measurement components and system

  • 1.1Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for a given work area are obtained and applied
  • 1.2Hazards are identified, risks assessed and control measures implemented
  • 1.3Nature of the flow measurement problem is identified from documentation and/or appropriate person/s to determine the scope of work to be undertaken
  • 1.4Appropriate person/s is consulted to ensure work is coordinated effectively with others
  • 1.5Materials required for the work are determined in accordance with workplace procedures
  • 1.6Tools, equipment and testing devices needed to carry out the work are obtained and checked for correct operation and safety in accordance with workplace procedures

2 Solve a flow measurement problems

  • 2.1WHS/OHS risk control work measures and workplace procedures are followed
  • 2.2Need to inspect, test or measure electrical components of live work is determined in accordance with job requirements and workplace safety procedures
  • 2.3Flow measurement apparatus is checked and isolated in accordance with WHS/OHS requirements and workplace procedures
  • 2.4Relevant methods/techniques are used to solve measurement problems and calculated values as they apply to flow measurement systems
  • 2.5Unplanned situations are responded to in accordance with workplace procedures and with the approval of an authorised person/s
  • 2.6Problems are resolved using sustainable energy principles and without damage to apparatus, the surrounding environment or services in accordance with workplace procedures

3 Complete work and document work activities

  • 3.1WHS/OHS work completion risk control measures and workplace procedures are followed
  • 3.2Worksite is cleaned and made safe in accordance with workplace procedures
  • 3.3Justification for solutions used to resolve flow measurement problem is documented
  • 3.4Work completion is documented and appropriate person/s notified in accordance with workplace procedures

Performance evidence

  • applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including:
  • applying safe work practices
  • implementing risk control measures
  • applying sustainable energy principles and practices
  • completing work and documenting work activities
  • connecting pneumatic, hydraulic and electric equipment
  • dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
  • identifying flow measurement components and system
  • identifying specifications, industry standards and equipment manuals
  • solving problems in flow measurement systems.

Knowledge evidence

  • introduction to flow measurement in closed conduits, including:
  • basic principles of fluid flow
  • International System of Units (SI) units pertaining to flow and conversion factors to SI units
  • volumetric and mass flow
  • Reynolds numbers
  • behaviour of fluid flow in pipes
  • correction methods
  • flow terminology
  • pressure loss
  • integration
  • uses of flow meters
  • types and applications of flow transducers
  • transducers input/outputs - measurement and evaluation
  • transducer connections
  • differential pressure flow measurement, including:
  • Bernoullis theorem and square root head law
  • calculations of the differential pressure
  • calibration of the associated secondary instrument
  • installation and types of differential pressure flow meters and primary elements
  • differential pressure flow measurement circuits, including define turndown and accuracy, output signals, square root extractors, scaling factors and signal scaling
  • electromagnetic, vortex and ultrasonic flow meters, including:
  • construction, operating principles, performance, application and installation
  • installation of vortex and ultrasonic flow meters
  • operating principles and applications of ultrasonic flow meters
  • flow measurement in closed conduits, including:
  • basic principles of fluid flow
  • behaviour of fluid flow in pipes
  • correction methods and flow terminology
  • integration, pressure loss, and Reynolds numbers
  • SI units pertaining to flow and conversion factors to SI units
  • types and applications of flow transducers, connections, and transducer input/outputs (I/O) - measurement and evaluation
  • uses of flow meters
  • volumetric and mass flow
  • mass flow measurement and volumetric flow rate correction, including:
  • applications, installation, operating principles and performance of mass flow meters
  • calculations of corrected flow rate
  • calibration of corrected systems components
  • mass flow measurement
  • volumetric flow rate correction
  • mechanical flowmeters for liquid service, including:
  • operating principles of mechanical flow meters
  • performance of mechanical flow meters
  • applications of mechanical flow meters
  • installation of mechanical flow meters
  • operating principles of gas flow meters
  • performance of gas flow meters
  • applications of gas flow meters
  • installation of gas flow meters
  • open-channel flow measurement and flow meter calibration, including:
  • calculations of the head generated
  • flow meter calibration
  • installation of open channel flow meters
  • non-linear head/flow relationships
  • open channel flow measurement
  • operating principles of secondary instruments
  • principles of fluid flow in open channels
  • principles of head/flow relationships
  • problems in flow measurement systems
  • relevant job safety assessments or risk mitigation processes, including risk control measures
  • relevant manufacturer specifications
  • relevant WHS/OHS legislated requirements
  • relevant workplace documentation
  • relevant workplace policies and procedures, including safe work practices
  • specifications, industry standards and equipment manuals
  • sustainable energy principles and practices
  • variable area flow meters and turbine flow meters, including;
  • applications, installation, and operating principles and performance of variable area and turbine meters
  • density correction calculations and scaling factors
  • variable area meters performance factors.

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEEIC0039

What does an assessment tool for UEEIC0039 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEIC0039 needs to address all 95 unit components: 3 elements with 16 performance criteria, 10 performance evidence requirements, 69 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEEIC0039?

Auditori pulls the current release of UEEIC0039 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEIC0039 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEEIC0039 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEIC0039, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEEIC0039 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEEIC0039 free