UEEIC0016Diagnose and rectify faults in a.c. motor drive systems

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UEEIC0016 must cover

40 assessable components: 3 elements (21 performance criteria), 12 performance evidence and 7 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to diagnose and rectify a.c. motor drive system faults

  • 1.1WHS/OHS processes and workplace procedures for a given work area are identified, obtained and applied
  • 1.2Hazards are identified, WHS/OHS risks assessed, and control measures and workplace procedures are implemented in preparation for work
  • 1.3Safety hazards that have not previously been identified are documented on job safety assessments and risk control measures devised and implemented in consultation with relevant person/s
  • 1.4Scope of fault/s is determined from fault report/s, relevant documentation and in consultation with relevant person/s
  • 1.5Relevant person/s is consulted to ensure work is coordinated effectively with others involved on the worksite
  • 1.6Tools, equipment and testing devices needed to diagnose faults are obtained in accordance with workplace procedures and checked for correct operation and safety

2 Diagnose and rectify a.c. motor drive system fault/s

  • 2.1WHS/OHS risk control measures and workplace procedures for carrying out work are followed
  • 2.2Need to inspect, test or measure live work is determined and conducted in accordance with WHS/OHS requirements and workplace procedures, as required
  • 2.3Circuits/machines/plant are inspected, checked and isolated, as required, in accordance with WHS/OHS requirements and workplace procedures
  • 2.4Logical diagnostic methods/techniques are applied to diagnose a.c. motor control system faults employing measurements and estimations of system operating parameters referenced to system operational requirements
  • 2.5Fault scenarios are tested and confirmed as being the source of system problems in accordance with workplace procedures
  • 2.6Causes of the faults are identified and relevant person/s identified to rectify the fault, as required, outside the scope of the a.c. motor drive control system
  • 2.7Faults in the control components of the system are rectified in accordance with a.c. motor control system operation standards
  • 2.8System is inspected and tested to verify that the system operates as intended and to specified requirements
  • 2.9Decisions for dealing with unplanned situations are determined from discussions with relevant person/s, job specifications and requirements
  • 2.10Methods for dealing with unplanned situations are selected on the basis of safety and specified work outcomes
  • 2.11Diagnosis and rectification activities are carried out efficiently, without unnecessary waste of materials or damage to apparatus, the surrounding environment or services using sustainable energy practices

3 Complete and report fault diagnosis and rectification activities

  • 3.1WHS/OHS work completion risk control measures and workplace procedures are followed
  • 3.2Worksite is made safe in accordance with workplace safety procedures
  • 3.3Rectification of faults is documented in accordance with workplace procedures
  • 3.4Relevant person/s is notified in accordance with workplace procedures that the system faults have been rectified

Performance evidence

  • applying logical diagnostic methods
  • applying problem-solving techniques
  • applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including: • implementing workplace procedures and practices • using of risk control measures
  • applying sustainable energy principles and practices
  • completing and reporting fault diagnosis and rectification activities
  • dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
  • documenting fault rectification activities and outcomes in accordance with workplace procedures
  • identifying faults and determining components needed to rectify them
  • inspecting, testing and verifying that the alternating current (a.c.) electrical system operates correctly
  • preparing to diagnose and rectify faults in a.c. motor drive system
  • rectifying faults in a.c. motor drive system controls
  • using fault scenarios to test the cause of system faults

Knowledge evidence

  • relevant job safety assessments or risk mitigation processes
  • relevant manufacturer specifications
  • relevant problem-solving techniques
  • relevant WHS/OHS legislated requirements
  • relevant workplace documentation
  • relevant workplace policies and procedures
  • variable speed drive (VSD) systems for a.c. motors, including: • methods and operating principles • installation requirements • filtering • performance characteristics • set-up and commissioning • common faults, their symptoms and causes

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEEIC0016

What does an assessment tool for UEEIC0016 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEIC0016 needs to address all 40 unit components: 3 elements with 21 performance criteria, 12 performance evidence requirements, 7 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEEIC0016?

Auditori pulls the current release of UEEIC0016 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEIC0016 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEEIC0016 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEIC0016, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEEIC0016 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEEIC0016 free