UEEHA0017 — Classify areas where a combustible dust hazard may arise
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEEHA0017 must cover
45 assessable components: 3 elements (12 performance criteria), 11 performance evidence and 22 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Determine the combustible characteristics of the material and extent of explosion hazard
- 1.1Knowledge of the factors considered in classification of combustible dust atmospheres is applied
- 1.2Consideration is given to reducing the extent of explosion hazards by the application of hierarchy of risk controls
- 1.3Dust combustibility is determined in consultation with process specialists and relevant sources of information and, where applicable, obtaining confirmation by commissioning laboratory tests
- 1.4Material characteristics such as particle size, moisture content, cloud and layer minimum ignition temperature and electrical resistivity, are obtained from process specialists and relevant sources of information and, where applicable, laboratory tests
- 1.5Dust containment and sources of release, including likely formation of dust layers are identified from process personnel with operational and maintenance experience
- 1.6The probability that dust will be released and form an explosive dust atmosphere in an installation is determined from possible causes and characteristics of release taking into account ventilation and dust extraction
2 Assign the type and extent of zones
- 2.1Sources and grades of release and dust deposits in layering that may occur in the area are established from collected data and consultation with process specialists
- 2.2Area classification zones are attributed according to the frequency and duration of the occurrence of explosive dust atmospheres
- 2.3The extent of each zone is determined in accordance with the relevant standard and in consideration of examples of locations that may give rise to a zone
- 2.4The nature of housekeeping is taken into account
3 Document classification and delineation of zones
- 3.1Area classification processes and procedures are documented as required by the relevant standards including the level of housekeeping on which the classification is based
- 3.2Classification documentation records are provided for future reference and for incorporation in the verification dossier
Performance evidence
- determining dust combustibility in consultation with process specialists and obtaining confirmation from laboratory tests and other sources
- obtaining relevant material characteristics from process specialists and, where applicable, laboratory tests and other sources
- identifying dust containment and sources of release, including likely formation of dust layers from process diagrams and plant drawings
- determining the probability that dust will be released and form an explosive dust atmosphere in an installation from possible causes and the characteristics of release
- considering the application hierarchy of risk controls to reducing the extent of explosion hazards
- establishing the sources and grades of release and dust deposits in layering that may occur in the area from collected data and in consultation with process specialists and site personnel
- attributing area classification zones according to the frequency and duration of the occurrence of explosive dust atmospheres and the extent of each zone
- determining the extent of each zone in accordance with the relevant standard
- consulting with plant management to develop strict housekeeping arrangements to negate the hazards posed by the formation of dust layers
- documenting the area classification processes and procedures as required by the relevant standards
- providing classification documentation records for future reference and for incorporation in the verification dossier
Knowledge evidence
- material characteristic (of a given process)
- dust groups
- normal operation
- abnormal operation
- start-up
- shut-down
- documenting results
- plant and process design
- examples of locations that may give rise to a given zone cited in the relevant standard
- formation of dust atmosphere outside equipment
- extent of dispersion of dust to a point where dust is not hazardous
- assigning grades of release
- frequency and duration of the occurrence of explosive dust atmospheres forming
- factors affecting the extent of zones
- how dust layers form
- behaviour of dust layers
- dust layers as an ignition source
- negating risk of dust layering
- all relevant information and references
- results material combustibility and process studies
- marked up drawings data sheets and table
- justifications for decisions made
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEEHA0017
What does an assessment tool for UEEHA0017 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEHA0017 needs to address all 45 unit components: 3 elements with 12 performance criteria, 11 performance evidence requirements, 22 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEEHA0017?
Auditori pulls the current release of UEEHA0017 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEHA0017 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEEHA0017 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEHA0017, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEEHA0004 — Enter a classified hazardous area to undertake work related to electrical equipment
- UEEHA0008 — Design gas detection systems
- UEEHA0016 — Assess the fitness-for-purpose of explosion-protected equipment
- UEEHA0018 — Classify areas where flammable gas or vapour hazards may arise
- UEEHA0019 — Conduct a conformity assessment review of explosion-protected equipment
- UEEHA0020 — Conduct detailed inspection of electrical installations for hazardous areas
- UEEHA0021 — Design explosion-protected electrical systems and installations
- UEEHA0022 — Determine the explosion-protection requirements to meet a specified classified hazardous area
- UEEHA0023 — Develop and manage periodic electrical inspection and maintenance programs for hazardous areas
- UEEHA0024 — Inspect, maintain and fit plugs/couplers for reeling, trailing and flexible cables - coal mining
- UEEHA0025 — Install explosion-protected equipment and associated apparatus and wiring systems
- UEEHA0026 — Maintain equipment associated with hazardous areas
Your UEEHA0017 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEEHA0017 free