UEEEL0063 — Provide photometric data for illumination system design
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEEEL0063 must cover
26 assessable components: 2 elements (9 performance criteria), 9 performance evidence and 8 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to provide photometric data
- 1.1Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for a given work area are identified, obtained and applied
- 1.2Illumination parameters of the design are obtained from a design brief, job specification and/or consultations with the client
- 1.3Illumination parameters for particular situations and tasks are obtained and applied in accordance with relevant industry standards
- 1.4Lighting manufacturer specification for products are obtained and reviewed
2 Provide photometric data
- 2.1WHS/OHS risk control work measures and workplace procedures are followed
- 2.2Photometric data is calculated for applications and variety of appropriate lighting products
- 2.3Data illumination is in accordance with relevant industry standards
- 2.4Data is documented in accordance with workplace procedures
- 2.5Photometric data documentation is forwarded to appropriate person/s in accordance with workplace procedures
Performance evidence
- obtaining illumination parameters from a design brief, job specification or by consultation with the client
- understanding compliance and recommended illumination parameters for particular situations and tasks
- understanding manufacturers’ technical information
- documenting photometric data, including justification for conclusions
- dealing with unplanned events
- applying industry standards
- applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures
- following workplace procedures
- providing photometric data, including: - applying manufacturer specifications - calculating photometric data
Knowledge evidence
- photometric principles, vision and colour, including: - nature of light encompassing: - dual nature of light electromagnetic spectrum - frequency and wavelength (nm) - photometric principles and definitions encompassing: - scope and definitions from AS/NZS 1680.1 Interior and workplace lighting - General principles and recommendations, and AS ISO 1000 – 1998 The international system of units (SI) and its application - luminous flux, definition and unit of measurement - luminous intensity, definition and International System of Units (SI) unit of measurement - radians and steradians - illuminance and luminance - basic optics, reflection and refraction - reflectance and transmittance - diffuse surfaces - the point source and the inverse square law - cosine law - relationship between watts and lumens - older imperial measurements (such as the footcandle or lumen per square foot and candlepower) - physiology of the eye and light detection encompassing: - scotopic, mesopic and photopic vision - contrast sensitivity - colour vision – rods and cones - light levels and recognition of colour - adaptation - accommodation and visual acuity - brightness and lightness - image detection - glare and comfort - cognition and visual perception - colour encompassing: - Munsell and CIE colour system - chromaticity coordinates - black body radiation and colour temperature - uniform chromaticity scale diagrams - factors determining colour appearance - photometry encompassing: - the integrating sphere - distribution photometry - selected requirements of AS/NZS 1680.3 Interior and workplace lighting - Measurement, calculation and presentation of photometric data - the goniophotometer - measurement of luminous flux - measurement of luminance and cut-off angle - measurement of illuminance (single luminaire) - graphical representation of photometric data - test reports and data presentation - lux meters and measuring equipment
- required light levels for various situations in accordance with Australian/New Zealand Standards
- relevant industry standards
- relevant job safety assessments or risk mitigation processes
- relevant manufacturer specifications and operating instructions
- relevant WHS/OHS legislated requirements
- relevant workplace documentation
- relevant workplace policies and procedures
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEEEL0063
What does an assessment tool for UEEEL0063 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEEL0063 needs to address all 26 unit components: 2 elements with 9 performance criteria, 9 performance evidence requirements, 8 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEEEL0063?
Auditori pulls the current release of UEEEL0063 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEEL0063 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEEEL0063 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEEL0063, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEEEL0001 — Apply compliance requirements to all aspects of electrical work
- UEEEL0002 — Apply currency of safe working practices and compliance verification of electrical installations
- UEEEL0003 — Arrange circuits, control and protection for electrical installations
- UEEEL0004 — Carry out basic repairs to electrical components and equipment
- UEEEL0005 — Develop and connect electrical control circuits
- UEEEL0006 — Develop detailed and complex drawings for electrical systems using CAD systems
- UEEEL0007 — Develop detailed electrical drawings
- UEEEL0008 — Evaluate and modify low voltage heating equipment and controls
- UEEEL0009 — Evaluate and modify low voltage lighting circuits, equipment and controls
- UEEEL0010 — Evaluate and modify low voltage socket outlets circuits
- UEEEL0011 — Evaluate performance of low voltage electrical apparatus
- UEEEL0012 — Install low voltage wiring, appliances, switchgear and associated accessories
Your UEEEL0063 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEEEL0063 free