UEEEL0045Diagnose and rectify faults in traction lift systems

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UEEEL0045 must cover

248 assessable components: 3 elements (20 performance criteria), 12 performance evidence and 216 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to diagnose and rectify lift system faults

  • 1.1WHS/OHS requirements and workplace procedures for a given work area are identified and applied
  • 1.2WHS/OHS risk control measures and workplace procedures in preparation for work are followed
  • 1.3Scope of work to be undertaken is determined from workplace procedures or fault/breakdown reports and/or discussions with appropriate person/s
  • 1.4Advice is sought from the work supervisor to ensure work is coordinated effectively with others
  • 1.5Tools, equipment and testing devices to carry out work are obtained in accordance with workplace procedures and checked for correct operation and safety

2 Diagnose and rectify lift system faults

  • 2.1WHS/OHS risk control measures and workplace procedures for carrying out work are followed
  • 2.2Need to test or measure live electrical work is determined in accordance with WHS/OHS requirements and, as required, conducted within workplace safety procedures
  • 2.3Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
  • 2.4Safety hazards resulting from fault or breakdown are documented on job safety assessments, risks assessed and control measured implemented in consultation with appropriate person/s
  • 2.5Logical diagnostic methods are applied to diagnose lift system apparatus faults employing measurements and estimations of system operating parameters referenced to system operational requirements
  • 2.6Suspected fault-finding scenarios are tested as being possible cause/s of lift system fault in accordance with workplace procedures
  • 2.7Cause of lift system fault/s is identified and appropriately competent person/s engaged to rectify the fault where it is outside the scope of the lift systems
  • 2.8Fault/s in the lift components of the system is rectified to apparatus manufacturer specifications and lift system relevant operational standards
  • 2.9System is inspected and tested to verify that the lift system operates as intended and to manufacturer specified requirements
  • 2.10Control methods for dealing with unplanned situations are responded to on the basis of workplace safety and specified work outcomes
  • 2.11Diagnosis and fault/s rectification activities are carried out efficiently without unnecessary waste of materials or damage to apparatus, the surrounding environment or services using sustainable energy practices

3 Complete rectification activities and documentation

  • 3.1WHS/OHS work rectification risk control measures and workplace procedures are followed
  • 3.2Reusable, faulty or worn components are tagged and despatched for repair in accordance with workplace procedures
  • 3.3Rectification of fault/s is documented in accordance with workplace procedures
  • 3.4Appropriate person/s is notified that the lift system fault/s has been rectified in accordance with workplace procedures

Performance evidence

  • applying sustainable energy principles and practices
  • applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures
  • completing and reporting fault diagnosis and rectification activities
  • dealing with unplanned events in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
  • diagnosing and rectifying faults in traction lift systems, including:
  • brakes
  • door components
  • governors
  • lift machines
  • safety devices
  • safety gear
  • preparing to diagnose and rectify faults.

Knowledge evidence

  • brake types, function, operation, inspection and adjustment, circuitry and manual release, including:
  • brake circuitry
  • electrical operations, including stall motor, solenoid and hydraulic
  • geared machine brakes
  • gearless machine brakes
  • inspection and adjustment of mechanical and electrical brakes
  • internal and external mechanical brakes
  • manual release devices and safety procedures
  • communication at site
  • electro-hydraulic lifts circuitry, controls and components, including:
  • electrical circuitry
  • faulty components diagnosis
  • governor switch
  • hydraulic circuitry
  • hydraulic components
  • levelling switch
  • over travel limits
  • pump motor and starter
  • servicing
  • stop button
  • up, down limit switches
  • up, down solenoids
  • electro-hydraulic lifts - mechanical operation – fluid power principles and components, operation, arrangements, lift code and other requirements and emergency passenger release, including:
  • bleeding lines
  • control of hydraulic pressure
  • directional flow including pressure gauge
  • filters
  • fluids
  • general operation
  • hydraulics
  • oil cooler
  • oil reservoir
  • Pascal’s Law
  • pump
  • ram/cylinders, including single and multi-stage
  • safety considerations of fluids under pressure
  • seals
  • solenoid values
  • types of arrangements, including side acting, direct and suspended
  • electric lifts – mechanics, including:
  • governor operation testing and rope tension testing
  • governor types, including vertical shaft, overspeed devices and horizontal shaft
  • governors
  • release procedures for each type of safety gear/governor combination
  • safety gear types: A instantaneous, B flexible guide clamp, C wedge clamp and D oil buffer
  • emergency release procedures - trapped passengers – WHS/OHS considerations and communication with passengers, including:
  • determining numbers and condition of passengers
  • direction of lift travel before stopping
  • emergency medical support
  • fault indication
  • hand winding
  • information related to impending movement and opening of doors
  • moving under power
  • passenger safety
  • reassurance as to safety of passengers
  • status of doors
  • warnings about standing near doors and using controls
  • escalators and moving walks components, including:
  • balustrade lighting
  • controller
  • drive chain
  • handrail
  • handrail earthing
  • machine brakes
  • rollers and tension carriage
  • safety devices
  • step/pallet chains
  • steps/pallets/belts
  • track systems
  • truss
  • geared types including rack and pinion and chain, including:
  • application
  • brakes
  • drum
  • efficiency
  • electric prime mover (motor types and control)
  • speed/load characteristics
  • lift car, including:
  • access
  • buttons and indicators
  • communication devices
  • door operator
  • frame
  • safety gear
  • superstructure
  • travelling cable
  • lift components - electro-mechanical employing relay logic components, including:
  • acceleration circuits
  • button circuit
  • directional circuitry
  • door operator circuitry
  • fans
  • floor selector circuitry
  • indicator/lantern circuit
  • key switch circuits
  • mains supply
  • motor room control (selector)
  • power circuits
  • re-levelling circuitry
  • slowing and stopping circuitry
  • well control (transducer)
  • lift components - electro-mechanical safety circuits, including:
  • car door locks
  • car top switch
  • car trap-door limit switch
  • circuit switches are all highlighted
  • emergency stop
  • fire service
  • landing door locks
  • pit switch
  • safety gear switch
  • tappet switch
  • terminal stopping
  • lift components – electrical, including:
  • brushes
  • fuses
  • lamps
  • limit switches
  • motor/generator
  • relays: reverse phase and phase failure
  • selectors
  • tachos
  • terminals
  • transformers
  • lift components - electronic, including:
  • capacitors
  • electronic boards
  • encoders
  • input/output (I/O) board
  • processor board
  • rectifiers
  • resistors
  • selectors
  • transducers
  • lift control circuits using relay logic, including:
  • acceleration, button, indicator/lantern, key switch and power circuits
  • directional, door operator, floor selector, re-levelling and slowing and stopping circuitry
  • fans
  • mains supply
  • motor room control (selector)
  • well control (transducer)
  • lift electrical layout and special requirements, including:
  • colour coding and labelling
  • communication cabling
  • conduits
  • segregation low voltage (LV)/extra-low voltage (ELV)
  • special lift symbols
  • travelling cable
  • troughing
  • lift machine room, including:
  • access
  • controller
  • floor selector
  • governor
  • machine
  • lift pit, including:
  • access
  • buffers
  • compensators
  • safety equipment
  • lift safety circuits, including:
  • car door locks
  • car top switch
  • car trap-door limit switch
  • circuit breakers
  • circuit switches
  • door protection
  • emergency stop
  • fire service
  • governor/switch
  • landing door locks
  • limit switches
  • overloads
  • phase failure relay
  • pit switch
  • reverse phase relay
  • safety gear switch
  • tappet switch
  • terminal stopping
  • lift systems - drive types, construction and operation of passenger, goods and service lifts, including:
  • drive constructions
  • drive types
  • emergency procedures
  • goods
  • passenger
  • rive operations
  • service
  • single and team manual handling
  • lift well equipment, including:
  • counterweights
  • guide rails
  • landing doors and locks
  • limit switches/operating devices
  • ropes
  • roping systems
  • maintenance, replacement and adjustment of mechanical lift components, including:
  • air cords
  • bearings: roller, sleeve, guide shoes and slipper
  • car doors
  • door guides
  • landing doors
  • selectors
  • tapes/chains
  • traction, including:
  • application
  • brakes
  • efficiency
  • electric prime mover (motor types and control)
  • speed/load characteristics
  • relevant job safety assessments or risk mitigation processes
  • relevant manufacturer specifications
  • relevant WHS/OHS legislated requirements
  • relevant workplace documentation
  • relevant workplace policies and procedures
  • sustainable energy principles and practices
  • relevant technical industry standards, regulations, statutory requirements and codes for lifts systems.

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEEEL0045

What does an assessment tool for UEEEL0045 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEEL0045 needs to address all 248 unit components: 3 elements with 20 performance criteria, 12 performance evidence requirements, 216 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEEEL0045?

Auditori pulls the current release of UEEEL0045 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEEL0045 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEEEL0045 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEEL0045, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEEEL0045 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEEEL0045 free