UEEEL0035Design effective and efficient lighting for public, open and sports areas

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UEEEL0035 must cover

72 assessable components: 3 elements (14 performance criteria), 14 performance evidence and 44 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to design lighting for public, open and sports areas

  • 1.1Work health and safety (WHS)/occupational health and safety (OHS) processes and workplace procedures for a given work area are identified, obtained and applied
  • 1.2Scope of the lighting requirement is identified from design brief
  • 1.3Safety and relevant conditions to the lighting design are identified, obtained and applied in accordance with relevant industry standards
  • 1.4Design development work is planned in consultation with relevant person/s involved in accordance with scheduled timelines

2 Develop lighting design

  • 2.1Relevant performance standards, compliance methods and lighting equipment is applied to lighting design in accordance with relevant industry standards
  • 2.2Alternative lighting designs are reviewed in accordance with the design brief
  • 2.3Safety, functionality, maintenance and budgetary considerations are incorporated in lighting design
  • 2.4Lighting design draft is checked in accordance with design brief and relevant industry standards
  • 2.5Lighting design is documented for submission to relevant person/s for acceptance and approval
  • 2.6Unplanned situations are dealt with in accordance with workplace procedure

3 Obtain approval for lighting design

  • 3.1Lighting design is documented and presented to client representative and/or relevant person/s
  • 3.2Requests for alterations to the design are negotiated with relevant person/s in accordance with workplace procedures
  • 3.3Final design is documented and approval obtained from relevant person/s
  • 3.4Quality of work is monitored in accordance with workplace procedures and relevant industry standards

Performance evidence

  • determining the extent and nature of the lighting requirements from a design brief
  • identifying and understanding safety and other requirements to which the lighting design shall comply
  • planning to meet scheduled timelines
  • applying appropriate knowledge of lighting performance compliance and lighting equipment in designing the lighting
  • considering alternative arrangements for the lighting design, including safety, functional, maintenance and budgetary factors in the lighting design
  • documenting and presenting the lighting design
  • responding appropriately to requests to alter the design
  • documenting and obtaining approval of the lighting design
  • dealing appropriately with unplanned events
  • applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures
  • developing lighting design
  • identifying and applying safety and relevant conditions in accordance with relevant industry standards
  • monitoring quality of work
  • preparing to design lighting for public, open and sports areas

Knowledge evidence

  • open area and sports lighting design for outdoor and sports application lighting, including:
  • reasons for quality lighting in sport
  • key terms in open area and sports lighting encompassing:
  • quantity of light required
  • horizontal luminance
  • vertical illuminance
  • illuminance uniformity
  • uniformity gradient
  • modelling and shadows
  • colour rendering
  • colour temperature
  • glare
  • emergency escape lighting
  • switching mode
  • emergency (continuity) TV lighting
  • obtrusive light
  • the sports lighting design process encompassing:
  • project definition
  • lighting study
  • questions for indoor and outdoor venues
  • lamp selection
  • luminaire selection
  • arrangement of luminaires
  • cost of ownership
  • installation
  • aiming, measuring and commissioning
  • maintenance
  • layout for lighting in multi-purpose halls and enclosed areas
  • sports grounds and stadiums:
  • lighting configuration
  • sports grounds with no spectator stand
  • sports grounds and stadiums with a spectator stand
  • swimming/diving areas
  • other considerations:
  • theatrical lighting effects and dynamic lighting
  • recommendations:
  • recommendations for non-televised events
  • classes of play
  • recommendations for televised events
  • problem-solving techniques
  • relevant manufacturer specifications and operating instructions
  • relevant job safety assessments or risk mitigation processes
  • relevant WHS/OHS legislated requirements
  • relevant workplace quality, instructions, policies and procedures

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEEEL0035

What does an assessment tool for UEEEL0035 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEEL0035 needs to address all 72 unit components: 3 elements with 14 performance criteria, 14 performance evidence requirements, 44 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEEEL0035?

Auditori pulls the current release of UEEEL0035 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEEL0035 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEEEL0035 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEEL0035, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEEEL0035 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEEEL0035 free