UEEEL0027 — Carry out low voltage electrical field testing and report findings
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEEEL0027 must cover
91 assessable components: 3 elements (17 performance criteria), 13 performance evidence and 61 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to carry out electrical field inspection and testing
- 1.1WHS/OHS requirements and workplace procedures for a given work area are identified, obtained and applied
- 1.2WHS/OHS risk control measures and workplace procedures in preparation for the work are followed
- 1.3Scope of work to be undertaken is determined from reports and/or discussions with appropriate person/s
- 1.4Advice is sought from the work supervisor to ensure work activity is coordinated effectively with others
- 1.5Tools, equipment and testing devices required to locate faults are obtained in accordance with workplace procedures and checked for correct operation and safety
2 Carry out electrical field inspection and testing
- 2.1WHS/OHS risk control measures and workplace procedures for carrying out work are followed
- 2.2Need to inspect, test and measure live electrical work is determined in accordance with WHS/OHS requirements and workplace procedures
- 2.3Circuits/machines/plant are isolated in accordance WHS/OHS requirements and workplace procedures
- 2.4Safety hazards from fault/s and/or breakdown are documented and risk control measures implemented in consultation with appropriate person/s
- 2.5Field testing and measuring techniques of electrical systems, circuits, and apparatus are conducted in accordance with workplace procedures
- 2.6Circuit/apparatus/components are dismantled as required to facilitate testing and parts stored for protection against loss or damage
- 2.7Tests are determined from report and appropriate testing/measuring instruments selected in accordance with manufacturer instructions and relevant industry standards
- 2.8Unplanned events are responded to in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
- 2.9Testing activities are carried out without damage to apparatus, circuits, environment or services using sustainable energy practices
3 Complete electrical field testing and report findings
- 3.1WHS/OHS work completion risk control measures and workplace procedures are followed
- 3.2Apparatus is reassembled after testing as required and work area is cleaned and made safe in accordance with workplace procedures
- 3.3Test findings and recommendation for actions are reported in accordance with workplace procedures
Performance evidence
- applying relevant industry standards
- applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures
- applying sustainable energy practices
- carrying out inspection and testing, including:
- selecting and setting up relevant testing/measuring instruments
- using relevant testing techniques
- using testing and measuring instruments
- completing electrical field inspection, testing and report findings
- dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
- following workplace procedures and instructions
- preparing electrical field testing, including:
- identifying work from reports and/or discussion with appropriate person/s
- locating tools, equipment and testing devices.
Knowledge evidence
- advanced electrical testing and measuring devices, including:
- testing/measuring devices and their application
- circuit arrangement and safety procedures for connection of testing/measuring devices into a circuit
- taking readings
- storage, maintenance and care of testing/measuring devices
- measurement concepts, including:
- notion of error, accuracy and resolution
- sources of measurement error and uncertainties
- instrument specifications and calibration certificates
- test and measuring instrument safety certification levels and their application
- types of field measuring instruments and their application, including:
- instrument meter movements and readouts, including moving coil, moving iron and dynamometer meter movements, liquid crystal display (LCD) digital and screen readouts
- role of a microprocessor/controller in measuring instrument
- measuring low voltages (LV) and direct currents (d.c.) and alternating currents (a.c.), including:
- LV and current measurement techniques embodied in microprocessor-based instruments
- causes of inaccuracies and overcoming them
- test instrument set-up and safety procedures
- interpreting test readings
- measuring high voltages (HV) and d.c. and a.c. including:
- HV and current measurement techniques embodied in microprocessor-based instruments
- causes of inaccuracies and overcoming them
- test instrument set up and safety procedures
- interpreting test readings
- measuring fault levels and (earth) fault-loop impedance, including:
- fault and fault-loop impedance measurement techniques embodied in microprocessor-based instruments
- causes of inaccuracies and overcoming them
- test instrument set-up and safety procedures
- interpreting test readings
- measuring power, energy, reactive power, power factor and maximum demand, including:
- power measurement techniques embodied in microprocessor-based instruments
- causes of inaccuracies and overcoming them
- test instrument set-up and safety procedures
- interpreting test readings
- measuring power quality, including:
- power measurement techniques embodied in microprocessor-based instruments
- causes of inaccuracies and overcoming them
- test instrument set-up and safety procedures
- interpreting test readings, including power quality measurement, including waveform distortion, harmonics, power factor and transients
- power cable faults and fault detection techniques, including:
- poor connection (high resistance)
- open circuit
- insulation breakdown and arcing
- Varley and Murray loop tests
- pulse test
- echo test
- radio-based tests
- application and limitations of the various cable fault detection techniques, including:
- cable fault detection techniques embodied in microprocessor-based instruments
- causes of inaccuracies and overcoming them
- test instrument set-up and safety procedures
- interpreting test readings
- problem-solving techniques
- relevant industry standards and codes of practice for electrical inspection and testing
- relevant job safety assessments or risk mitigation processes
- relevant manufacturer specifications and operating instructions for tools and equipment
- relevant quality workplace procedures
- relevant sustainable energy practices
- relevant tools, equipment, resources and materials
- relevant WHS/OHS legislated requirements
- relevant workplace documentation
- relevant workplace policies, procedures and instructions.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEEEL0027
What does an assessment tool for UEEEL0027 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEEL0027 needs to address all 91 unit components: 3 elements with 17 performance criteria, 13 performance evidence requirements, 61 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEEEL0027?
Auditori pulls the current release of UEEEL0027 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEEL0027 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEEEL0027 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEEL0027, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEEEL0001 — Apply compliance requirements to all aspects of electrical work
- UEEEL0002 — Apply currency of safe working practices and compliance verification of electrical installations
- UEEEL0003 — Arrange circuits, control and protection for electrical installations
- UEEEL0004 — Carry out basic repairs to electrical components and equipment
- UEEEL0005 — Develop and connect electrical control circuits
- UEEEL0006 — Develop detailed and complex drawings for electrical systems using CAD systems
- UEEEL0007 — Develop detailed electrical drawings
- UEEEL0008 — Evaluate and modify low voltage heating equipment and controls
- UEEEL0009 — Evaluate and modify low voltage lighting circuits, equipment and controls
- UEEEL0010 — Evaluate and modify low voltage socket outlets circuits
- UEEEL0011 — Evaluate performance of low voltage electrical apparatus
- UEEEL0012 — Install low voltage wiring, appliances, switchgear and associated accessories
Your UEEEL0027 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEEEL0027 free