UEEEL0023Terminate cables, cords and accessories for low voltage circuits

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UEEEL0023 must cover

76 assessable components: 3 elements (15 performance criteria), 12 performance evidence and 48 knowledge evidence requirements, plus 1 foundation skills. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to terminate cables, cords and conductors

  • 1.1WHS/OHS requirements and workplace procedures for a given work area are identified and applied
  • 1.2Hazards are identified, risks assessed and risk control measures and workplace procedures implemented in accordance with workplace procedures
  • 1.3Safety hazards that have not previously been identified are noted on job safety assessments and existing risk control measures are implemented
  • 1.4Junction box/terminal enclosures and terminal types are inspected to determine the type and size of cable and conductor termination devices needed
  • 1.5Tools, materials and testing devices needed for terminating cables and cords are obtained in accordance with workplace procedures and checked for correct operation and safety

2 Terminate cables, cords and conductors

  • 2.1WHS/OHS risk control measures and procedures for carrying out the work are followed
  • 2.2Circuits/machines/plant are checked as isolated, as required, in accordance with WHS/OHS requirements and workplace procedures
  • 2.3Cable/cord ends are cut and sheath/insulation stripped with sufficient length to prevent strain on terminations and without undue waste
  • 2.4Cable glands/retaining devices are fitted and secured to ensure cable/cord cannot be pulled out of entry into junction box/terminal enclosure
  • 2.5Conductors are prepared to suit the terminal type they are to be connected to
  • 2.6Conductors are terminated to ensure continuity across the terminal
  • 2.7Methodology for dealing with unplanned situations are discussed with appropriate person/s and documented
  • 2.8Unplanned situations are responded to safely in accordance with workplace procedures, in a manner that minimises risk to personnel, equipment and with the approval of an authorised person

3 Test terminated cables and cords

  • 3.1WHS/OHS work completion risk control measures and workplace procedures are followed
  • 3.2Terminated cables are tested to ensure continuity and insulation resistance comply with relevant industry standards

Performance evidence

  • applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures and practices, including using risk control measures
  • applying sustainable energy principles and practices
  • confirming relevant circuits are isolated
  • dealing with unplanned events in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
  • terminating wiring and accessories for low voltage circuits, including:
  • # cutting cable ends and stripping sheath/insulation to a sufficient length
  • # fitting and securing cable glands/retaining devices correctly
  • # preparing and terminating conductors to suit the type of terminal at which they are to be connected
  • # selecting appropriate cable/cord and conductor devices
  • # testing completed cables to ensure compliant continuity and insulation resistance
  • # inspecting junction box/terminal enclosures and determining the type and size of required cable and conductor termination devices
  • # testing terminated cables and cords

Knowledge evidence

  • cable types and terminations, including:
  • application of various cords and cables types, as defined by the properties of their insulation, sheathing, armouring and/or screening
  • Australian and international colour standards for cords and cables
  • single cables, flexible cables, flexible cords, screened cables, armoured cables, other similar and like cables
  • construction of common cables
  • identification of cords and cables by conductor size, type and rating
  • identification of hardware used in terminating cords and cables
  • requirements to protect and support cables adequately (protection against mechanical damage, protection from adverse temperatures and corrosion and protection from magnetic field that may affect the performance of the cable)
  • structural components of cables and their purpose (conductor material, stranding, insulation type, voltage rating, screening, sheathing, armour and serving)
  • techniques for termination of cords and cables using crimp lugs, tunnel connectors, soldering and solderless lugs
  • cords, cables and plugs, including:
  • techniques for selection of flexible cords for given applications
  • preparation of cord ends for connection
  • fitting standard three pin plug tops and extension sockets to flexible cords
  • connecting a variety of plug tops and extension sockets to different flexible cord types
  • flat thermoplastic sheathed (TPS) wiring systems, including techniques for:
  • installation of flat TPS cable in trunking and duct for the supply of socket outlets
  • using flat TPS cable for lighting looms
  • circular TPS wiring systems, including techniques for:
  • installation of circular TPS cables on cable ladder/tray
  • installation of circular TPS cable
  • thermoplastic insulated (TPI) cables in non-metallic enclosures, including techniques for:
  • cutting and setting rigid non-metallic ducting, trunking and conduit and accessories
  • installation of circuits using TPI cables in non-metallic enclosures
  • TPI cables in metallic enclosures, including techniques for:
  • fitting metallic conduit to metallic trunking and accessories
  • cutting, threading and setting metallic conduit
  • installation of circuits using TPI cables in metallic conduit, ducting and trunking
  • fire protection cabling and systems encompassing:
  • requirements when passing a wiring system through a fire rated wall or floor
  • techniques for recognising different fire protection cable types
  • techniques for installation and termination of fire protection cable
  • steel wire armoured (SWA) cables, including techniques for:
  • identifying accessories used with SWA cables
  • installation of circuits using SWA cables
  • trailing cables and catenary systems, including techniques for:
  • identifying equipment used with trailing cable and catenary systems
  • installation of catenary wiring systems
  • installation of trailing cable systems supplying pendant sockets
  • relevant industry standards and testing requirements for safe operation relating to:
  • cords, cables and plugs
  • circular and flat TPS wiring systems
  • TPI cables in non-metallic enclosures
  • TPI cables
  • fire protection cabling
  • SWA cables
  • trailing cables and catenary systems
  • relevant manufacturer specifications

Foundation skills

  • Foundation skills: Foundation skills essential to performance are explicit in the performance criteria of this unit of competency.

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEEEL0023

What does an assessment tool for UEEEL0023 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEEL0023 needs to address all 76 unit components: 3 elements with 15 performance criteria, 12 performance evidence requirements, 48 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEEEL0023?

Auditori pulls the current release of UEEEL0023 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEEL0023 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEEEL0023 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEEL0023, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units