UEEEC0036Fault find and repair sonar apparatus and systems

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UEEEC0036 must cover

104 assessable components: 3 elements (21 performance criteria), 15 performance evidence and 68 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to find and repair faults

  • 1.1WHS/OHS requirements and workplace procedures for relevant work area are identified, obtained and applied
  • 1.2Risk control measures are applied in accordance with workplace procedures prior to commencing work
  • 1.3Risks/hazards are identified, assessed and reported to relevant person/s, and control measures implemented
  • 1.4Extent of faults are determined from reports, other documentation and discussions with relevant person/s
  • 1.5Relevant person/s is consulted to ensure the work is coordinated effectively with others
  • 1.6Tools, equipment and testing devices required to diagnose faults are obtained in accordance with workplace procedures and checked for correct operation and safety

2 Find and repair fault

  • 2.1Workplace risk control measures and procedures are applied
  • 2.2Need to test and measure live work is determined in accordance with WHS/OHS requirements and workplace procedures
  • 2.3Circuits/machines/plant are checked and isolated, as required, in accordance with WHS/OHS requirements and workplace procedures
  • 2.4Logical diagnostic methods are applied to diagnose sonar apparatus and system faults employing measurements and estimations of system operating parameters referenced to system operational requirements
  • 2.5Suspected fault scenarios are tested in accordance with workplace procedures and job specifications
  • 2.6Source of the fault is identified and relevant person/s engaged to rectify fault in accordance with workplace procedures and relevant industry standards
  • 2.7Faults in electronic components are rectified to raise sonar apparatus and system to its operation standard
  • 2.8System is tested to verify that the system operates as intended and to specified requirements
  • 2.9Decisions for dealing with unplanned situations are made based on job specifications and requirements and discussions with relevant person/s
  • 2.10Methods for dealing with unplanned situations are selected on the basis of safety and specified work outcomes
  • 2.11Diagnosis and rectification activities are carried out efficiently without waste of materials, damage to apparatus, the surrounding environment or services applying sustainable energy practices

3 Complete and report fault-finding and repair activities

  • 3.1WHS/OHS work completion risk control measures and workplace procedures are followed
  • 3.2Worksite is made safe in accordance with workplace procedures
  • 3.3Rectification of faults is reported in accordance with workplace procedures
  • 3.4Relevant person/s is notified that the system faults have been rectified in accordance with workplace procedures

Performance evidence

  • applying logical diagnostic methods
  • using fault scenarios to test the source of system faults
  • identifying faults and competency needed to rectify them
  • rectifying faults in system electronics
  • verifying that the system operates correctly
  • documenting fault rectification
  • applying relevant risk identification, assessment, reporting and control requirements
  • applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including the use of risk control measures
  • applying sustainable energy principles and practices
  • coordinating work with relevant person/s
  • dealing effectively with unplanned events
  • determining live testing/measurement requirements
  • determining scope of work
  • identifying and accessing materials, tools, apparatus and testing devices
  • isolating circuits/machines/systems.

Knowledge evidence

  • sonar apparatus and system fault finding and repair, safe working practices and relevant standards codes and regulations, including:
  • electronic communications, sonar system operating principles:
  • the purpose and application of sonar systems
  • sonar equipment encompassing:
  • types and their applications
  • sub-system components (i.e. functional blocks) and their function encompassing:
  • transducer
  • input amplifier
  • sonar interface unit
  • beam forming network (transmit/receive)
  • signal processing
  • own Doppler nullification
  • display system
  • headset
  • interfaces
  • transmitter
  • T/R switch
  • timer/timing
  • sonar operating parameters
  • sonar transmission characteristics
  • electronic communications, sonar transducers and arrays:
  • hazards and risk control measures
  • transducer types, their operating principles and parameters
  • transducer array encompassing:
  • types and their construction
  • applications
  • transducer hull outfits
  • beam forming principles and requirements
  • transducer installation and operational maintenance
  • electronic communications, sonar measurement and set-up:
  • sonar parameters and measurements
  • sonar physical parameters
  • constraints and consequences
  • electronic communications, radar and sonar displays devices:
  • types and their applications – cathode-ray tube (CRT), plasma, liquid-crystal display (LCD), monochrome, colour and touch screen
  • sub-system components (i.e. functional blocks) and their operating parameters encompassing:
  • extra high tension (EHT) transformers
  • detectors
  • video distribution
  • time base generators
  • phase locked loops
  • microprocessors
  • memory devices
  • demodulators
  • focusing/deflection devices
  • delay lines
  • bleed resistors
  • high voltage (HV) generation
  • calibration testing and maintenance procedures
  • typical fault finding, their symptoms and cause
  • advanced electronic (sonar) testing and measuring devices and techniques:
  • test/measuring devices and their application - frequency counters, and synthesisers, spectrum analysers, noise and distortion meters and radio frequency (RF) communications service monitor
  • connection of test/measuring devices into a circuit encompassing:
  • safety procedures
  • loading and matching
  • storage and delay
  • circuit arrangement of test/measuring devices
  • taking and interpreting readings
  • notion of decibels, including dBm, dBr, dBu and dBo
  • fault finding and repair:
  • typical faults, their symptoms and cause
  • fault diagnosis procedures and testing
  • component replacement
  • equipment adjustments
  • relevant manufacturer specifications
  • relevant WHS/OHS legislated requirements
  • relevant workplace documentation
  • relevant workplace policies and procedures.

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEEEC0036

What does an assessment tool for UEEEC0036 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEEC0036 needs to address all 104 unit components: 3 elements with 21 performance criteria, 15 performance evidence requirements, 68 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEEEC0036?

Auditori pulls the current release of UEEEC0036 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEEC0036 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEEEC0036 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEEC0036, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEEEC0036 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEEEC0036 free