UEEEC0030Fault find and repair electronic medical equipment

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UEEEC0030 must cover

69 assessable components: 3 elements (21 performance criteria), 15 performance evidence and 33 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to find and repair faults

  • 1.1Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for relevant work area are identified, obtained and applied
  • 1.2Risk control measures are applied in accordance with workplace procedures prior to commencing work
  • 1.3Risks/hazards are identified, assessed and reported to relevant person/s, and control measures implemented
  • 1.4Extent of faults is determined from reports, other relevant documentation and discussions with relevant person/s
  • 1.5Relevant person/s is consulted to ensure the work is coordinated effectively with others
  • 1.6Tools, equipment and testing devices required to diagnose faults are obtained in accordance with workplace procedures and checked for correct operation and safety

2 Find and repair faults

  • 2.1Workplace risk control measures and workplace procedures are applied
  • 2.2Need to test and measure live work is determined in accordance with WHS/OHS requirements and workplace procedures
  • 2.3Circuits/machines/plant are isolated, as necessary, in accordance with WHS/OHS requirements and workplace procedures
  • 2.4Logical diagnostic methods are applied to diagnose electronic medical equipment faults employing measurements and estimations of system operating parameters referenced to system operational requirements
  • 2.5Suspected fault scenarios are tested as being the source of system problems
  • 2.6Source of the fault is identified and appropriately qualified person/s engaged to rectify the fault where it is outside the scope of capability in accordance with workplace procedures
  • 2.7Faults in electronic components are rectified to raise electronic medical equipment to its operation standard
  • 2.8System is tested to verify that it operates as intended and to specified requirements
  • 2.9Decisions for dealing with unexpected situations are made based on job specifications, work requirements and discussions with relevant person/s
  • 2.10Methods for dealing with unplanned situations are selected on the basis of safety and specified work outcomes
  • 2.11Diagnosis and rectification activities are carried out efficiently without waste of materials, damage to apparatus, the surrounding environment or services applying sustainable energy practices

3 Complete and report fault-finding and repair activities

  • 3.1Workplace risk control measures and workplace procedures are applied
  • 3.2Worksite is made safe in accordance with workplace procedures
  • 3.3Rectification of faults is reported in accordance with workplace procedures
  • 3.4Relevant person/s is notified that the system faults have been rectified in accordance with workplace procedures

Performance evidence

  • applying logical diagnostic methods
  • using fault scenarios to test the source of system faults
  • identifying faults and competency needed to rectify them
  • rectifying faults in system electronics
  • verifying that the system operates correctly
  • documenting fault rectification
  • dealing with unplanned events
  • applying relevant risk identification, assessment, reporting and control requirements
  • applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including the use of risk control measures
  • applying sustainable energy principles and practices
  • coordinating work with relevant person/s
  • determining live testing/measurement requirements
  • determining scope of work
  • identifying and accessing materials, tools, apparatus and testing devices
  • isolating circuits/machines/systems

Knowledge evidence

  • electronic medical equipment fault finding and repair, safe working practices and relevant standards, codes and regulations, including:
  • medical equipment principles: equipment categories, types, functions and operation
  • hazards and safety procedures
  • causes of failure
  • safety testing requirements and methods
  • categories and examples of medical equipment, including:
  • cardiovascular systems: blood warmers, cardiac catheterisation systems and defibrillators
  • electrocardiogram (ECG) machines, ECG monitors, heart-lung machines and infusion
  • pumps, intra-aortic balloon pumps, pacemakers, syringe pump and cardiac output measurement equipment
  • respiratory systems: anaesthetic delivery and monitoring units, medical gases, oxygen concentrator, pulse oximeter, respiratory humidifier, respiratory support units and ventilators
  • neurological systems: electroencephalograph (EEG) recorder, electromyograph (EMG) recorder and intracranial pressure (ICP) monitoring
  • renal systems: haemodialysis machine, continuous veno-venous hemofiltration (CVVH) machine and peritoneal dialysis
  • medical imaging: x-ray equipment, computerised axial tomography (CAT scan), magnetic resonance imaging (MRI), nuclear medicine and diagnostic ultrasound equipment
  • physiological equipment: blood pressure monitors, foetal cardiotocograph, infant care systems, multiparameter systems, thermometry, telemetry, networking and patient warmers
  • miscellaneous equipment: electrosurgery, electric stimulators, and endoscopy and laparoscopy systems, laser, operating microscopes, therapeutic diathermy and ultrasound
  • medical equipment, anatomy and physiology and infection control:
  • nature of infection
  • control of microbial growth
  • infection control strategies
  • body systems
  • medical equipment safe working practices:
  • risk management and assessment of risk encompassing: principle and purpose of risk management, and processes for conducting a risk assessment
  • hazards associated with medical equipment, encompassing: infections, toxic materials, electrical components, radiation
  • risks and control measures associated with working with medical equipment
  • fault finding and repair:
  • typical faults, their symptoms and cause
  • fault diagnosis procedures and testing
  • component replacement
  • equipment adjustments
  • relevant manufacturer specifications
  • relevant WHS/OHS legislated requirements
  • relevant workplace documentation
  • relevant workplace policies and procedures

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEEEC0030

What does an assessment tool for UEEEC0030 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEEC0030 needs to address all 69 unit components: 3 elements with 21 performance criteria, 15 performance evidence requirements, 33 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEEEC0030?

Auditori pulls the current release of UEEEC0030 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEEC0030 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEEEC0030 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEEC0030, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.