UEEEC0022Diagnose and rectify faults in camera circuits and equipment

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UEEEC0022 must cover

57 assessable components: 3 elements (19 performance criteria), 9 performance evidence and 29 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to diagnose and rectify camera circuits and equipment faults

  • 1.1Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for a given work area are identified and applied
  • 1.2WHS/OHS risk control measures and workplace procedures are followed in preparation for camera circuits and equipment work
  • 1.3Safety hazards that have not previously been identified are risk assessed, documented and risk control measures devised and implemented in consultation with appropriate person/s
  • 1.4Extent of faults is determined from reports, documentation and discussions with appropriate person/s
  • 1.5Appropriate person/s is consulted to ensure the camera circuits and equipment work is coordinated effectively with others involved on the worksite
  • 1.6Tools, equipment and testing devices needed to diagnose faults are obtained in accordance with workplace procedures and checked for correct operation and safety

2 Diagnose and rectify camera circuits and equipment faults

  • 2.1WHS/OHS risk control measures and workplace procedures for carrying out camera circuits and equipment work are followed
  • 2.2Need to test and measure live work is determined in accordance with WHS/OHS requirements and, as required, conducted within workplace safety procedures
  • 2.3Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
  • 2.4Logical diagnostic methods are applied to diagnose camera circuit faults using measurements of circuit operating parameters in accordance with camera operating specifications
  • 2.5Suspected fault scenarios are tested as being the source of camera circuit problems
  • 2.6Faults in the electronic components of the camera circuits are rectified to camera circuits operation and industry standards
  • 2.7Circuits are inspected and tested to verify that the camera operates to specified requirements
  • 2.8Unplanned situations are responded to in accordance with workplace procedures, discussions with appropriate person/s and consistent with job specifications and requirements in a manner that minimises risk to personnel and equipment
  • 2.9Diagnosis and rectification activities are carried out efficiently without waste of materials or damage to apparatus, the surrounding environment or services using sustainable energy practices

3 Complete and report fault diagnosis and rectification activities

  • 3.1WHS/OHS work completion risk control measures and workplace procedures are followed
  • 3.2Worksite is made safe in accordance with workplace safety procedures
  • 3.3Rectification of faults is documented in accordance with workplace procedures
  • 3.4Appropriate person/s is notified in accordance with workplace procedures that camera circuit faults have been rectified

Performance evidence

  • applying logical diagnostic methods
  • using fault scenarios to test the source of circuit faults
  • identifying the cause faults using logical diagnostic methods
  • rectifying faults effectively
  • verifying that the camera operates correctly
  • documenting fault rectification
  • dealing with unplanned events
  • applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, workplace procedures and practices, including using risk control measures
  • applying sustainable energy principles and practices

Knowledge evidence

  • camera circuits and equipment diagnostics safe working practices and relevant standards, codes and regulations, including:
  • operation of camera circuits
  • recording media, standards and formats
  • pick-up tubes and charge coupled devices
  • operation of optical transducers and lenses
  • colour separation techniques and signal processing
  • charge coupled devices
  • mechanics and adjustments
  • power supplies and batteries
  • MPEG capability
  • camera circuit diagnosis encompassing:
  • sub-system components (i.e. functional blocks) and their operating parameters
  • environment factors effecting system performance
  • typical faults, their symptoms and cause
  • fault diagnosis procedures and testing
  • sub-system adjustments
  • WHS/OHS enterprise responsibilities encompassing:
  • provisions of relevant WHS/OHS legislation
  • principles and practice of effective WHS/OHS management
  • management arrangements relating to regulatory compliance
  • enterprise hazards and risks, control measures and relevant expertise required
  • characteristics and composition of workforce and their impact on WHS/OHS management
  • relevance of enterprise management systems to WHS/OHS management
  • analysis of working environment and design of appropriate WHS/OHS management systems
  • analysis of relevant data and evaluation of WHS/OHS effectiveness
  • assess resources to establish and maintain WHS/OHS systems
  • relevant manufacturer specifications
  • relevant workplace documentation
  • relevant workplace policies and procedures

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEEEC0022

What does an assessment tool for UEEEC0022 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEEC0022 needs to address all 57 unit components: 3 elements with 19 performance criteria, 9 performance evidence requirements, 29 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEEEC0022?

Auditori pulls the current release of UEEEC0022 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEEC0022 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEEEC0022 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEEC0022, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEEEC0022 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEEEC0022 free