PMAOPS347Create and conduct isolations in the workplace

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for PMAOPS347 must cover

64 assessable components: 4 elements (17 performance criteria), 1 performance evidence and 41 knowledge evidence requirements, plus 5 foundation skills. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Plan and prepare for isolations according to procedures

  • 1.1Communicate with relevant stakeholders to confirm the scope of work, and the need for timing of the isolation
  • 1.2Identify hazards in the system that need to be controlled to a state of zero energy
  • 1.3Create appropriate isolation documents using current workplace isolation procedures
  • 1.4Verify isolation design
  • 1.5Submit isolation documentation according to workplace isolation submission chain-of-custody requirements

2 Conduct isolations

  • 2.1Confirm with stakeholders that isolation is ready to proceed
  • 2.2Conduct the isolation according to isolation design and operating procedures
  • 2.3Remove energy input and hazardous inventory in accordance with operating procedures
  • 2.4Ensure isolation integrity is performed according to operating procedures
  • 2.5Participate in appropriate handovers of equipment and isolation documentation according to operating procedures

3 Maintain Isolations

  • 3.1Maintain isolation integrity according to operating procedures
  • 3.2Take corrective action when isolation integrity is no longer effective

4 Conduct de- isolations

  • 4.1Confirm process plant is mechanically complete
  • 4.2Obtain de-isolation documentation according to operating procedures
  • 4.3De-isolate and reinstate plant according to operating procedures
  • 4.4Maintain appropriate communication with relevant stakeholders
  • 4.5Finalise documentation according to operating procedures

Performance evidence

  • at least 2 times, each in a separate work context.

Knowledge evidence

  • physical plant and equipment including:
  • the equipment/process being isolated
  • energy sources relevant to plant equipment
  • policies and procedures including:
  • methods of creating isolations
  • methods of de-energising and isolating energy sources
  • the scope/boundaries of own role when creating and conducting the isolations
  • safety, emergency and hazard control
  • work permit systems
  • risk control measures and procedures
  • hierarchy of control
  • isolation requirements
  • methods of purging, venting, bleeding, draining and flushing
  • isolation chain of custody and handover protocols
  • communications
  • environmental management including controlling releases
  • duty of care requirements
  • standard operating procedures (SOPs)
  • work instructions
  • safe work method statements (SWMS)
  • document control
  • operational parameters including:
  • methods and equipment used for draining and purging to attain zero energy
  • decontamination methods and requirements for various materials and situations
  • significance of time allowed for draining, purging and ventilation
  • fluid dynamics relating specifically to draining piping systems, including:
  • the ability of a liquid to ‘hang-up’ in pipework
  • the importance of identifying high-point vents to release gas/vapours and low point drains to release liquids
  • how to determine the amount of liquid drained from a piping section to ascertain/prove that draining process has been effective
  • the potential effects of creating a vacuum by not draining correctly (e.g. by pulling a vacuum behind a slug of liquid)
  • the ALARP (as low as reasonably practicable) principle
  • importance of appropriate rates of change for pressure and temperature for vessels and other plant equipment
  • risk management including:
  • the chemical and physical properties of the energy sources being isolated including one or more of the following:
  • electricity (mains, solar and by generator)
  • chemicals and fuels
  • heat and steam
  • pressure, such as compressed air and water, hydraulic oil and other fluids under pressure
  • energy-storing devices such as batteries, springs, flywheels, accumulators and capacitors.
  • trapped pressure
  • site requirements in completion of bleed logs.

Foundation skills

  • Learning skills: to follow instructions, monitor process and select appropriate procedure.
  • Reading skills: to follow written procedures and documentation.
  • Writing skills: to complete workplace documentation.
  • Oral communication skills: to liaise and coordinate with team members and the control-room operator.
  • Numeracy skills: to monitor field data, instrumentation and process parameters.

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing PMAOPS347

What does an assessment tool for PMAOPS347 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for PMAOPS347 needs to address all 64 unit components: 4 elements with 17 performance criteria, 1 performance evidence requirements, 41 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for PMAOPS347?

Auditori pulls the current release of PMAOPS347 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for PMAOPS347 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing PMAOPS347 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of PMAOPS347, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your PMAOPS347 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate PMAOPS347 free