PMAOPS344 — Operate and troubleshoot flare systems
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for PMAOPS344 must cover
72 assessable components: 4 elements (21 performance criteria), 1 performance evidence and 45 knowledge evidence requirements, plus 5 foundation skills. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Operate flare system in accordance with procedures
- 1.1Receive and give shift handover
- 1.2Identify type of flare system and duty/standby status of relevant equipment
- 1.3Monitor flare system frequently and critically throughout shift using own senses, and measured and indicated data
- 1.4Ensure the flare system is running within stated operational tolerances as requested by the control room operator
2 Identify and respond to abnormal situations
- 2.1Identify problems within the flare system and problems in other units that will impact flare system operation
- 2.2Take action to remedy abnormal flare situations in according to operating procedures, and as required by control room
- 2.3Verify the asset integrity of all flare equipment and respond to integrity breaches according to operating procedures
- 2.4Maintain appropriate communication with control-room operator during abnormal flare situations
- 2.5Assess flare incidents and notify appropriate personnel of the incident according to operating procedures
- 2.6Complete required documents outlining abnormal flare situation management including corrective action taken
3 Shutdown and prepare flare system for maintenance
- 3.1Identify maintenance scope from workplace documentation
- 3.2Prepare flare system for duty changeover according to operating procedures
- 3.3Maintain appropriate communication with control-room operator during flare system duty changeover
- 3.4Identify, control and report shutdown hazards
- 3.5Isolate flare systems and utilities from operating sources according to operating procedures
- 3.6Leave the shutdown flare system in a safe state for handover to maintenance
4 Prepare and start up flare system
- 4.1Check that any maintenance or other performed work has been completed
- 4.2De-isolate flare system equipment according to operating procedures
- 4.3Complete flare system pre-start checks according to operating procedures
- 4.4Identify, control and report startup hazards
- 4.5Maintain appropriate communication with control-room operator during the flare startup
Performance evidence
- at least 2 times, each in a separate work context.
Knowledge evidence
- physical plant and equipment including: all items on flare system schematics and the function of each
- physical plant and equipment including: flare equipment terminology
- policies and procedures including: where to locate latest version of workplace maintenance documents and procedures
- policies and procedures including: required preparation and permits for different types of work to be done on the flare unit or its component items
- policies and procedures including: isolation requirements
- policies and procedures including: role within permit system when taking flare custody back from maintenance
- policies and procedures including: de-isolation principles
- operating parameters including: basic flare-specific physics and chemistry relevant to operation of the flare system equipment and of the relevant upstream processes, to the level of being able to interpret the science and extract factors controlling the flare operation:
- smokeless combustion
- negative pressures after flaring hot vapours
- Joule–Thompson effect
- air ingress
- operating parameters including: flare duty of care obligations
- operating parameters including: key operating principles of flare equipment and associated ancillary equipment
- operating parameters including: flare safe operating envelope for relevant process variables
- operating parameters including: interactions between plant items/processes and the flare
- operating parameters including: factors affecting efficient operation of the equipment
- operating parameters including: specific key alarms and appropriate actions
- operating parameters including: impact of external factors including variations in weather and feed
- operating parameters including: the following signs of flare unit upset and corrective actions:
- high level or low level in knockout drum
- icing up of flare lines or valves
- low flare header pressure
- loss of pilot gas or minimal gas flow
- oxygen alarm
- flame sensor alarm
- black smoke – understanding the Ringelmann scale
- extinguished pilot burners
- flare height and noise levels
- pulsing flame – relief valve chattering
- operating parameters including: flare integrity limits, regulatory specifications and tolerances
- operating parameters including: function and basic troubleshooting of major internal components
- operating parameters including: the advantages and disadvantages of changing each of the variables during flare operational upsets
- operating parameters including: correct methods of changing duty of flare equipment
- operating parameters including: correct methods of reinstating and starting flare systems
- risk management including: key safety systems and relevant procedures
- risk management including: knock on and escalation potential from process upsets and actions
- risk management including: emergency shutdown procedures and communication protocols
- risk management including: locations of muster points, spill kits, emergency response beacons and equipment relevant to the flare system
- risk management including: incident response role requirements within site safety management plan
- risk management including: appropriate application of hierarchy of control measures to control risks
- risk management including: flare system hazards: possible causes
- risk management including: flare system hazards: potential consequences
- risk management including: flare system hazards: appropriate risk controls
- risk management including: reporting and escalation procedures
Foundation skills
- Learning skills: to follow instructions, monitor process and select appropriate procedure.
- Reading skills: to follow written procedures and documentation.
- Writing skills: to complete workplace documentation
- Oral communication skills: to liaise and coordinate with team members and the control-room operator.
- Numeracy skills: to monitor field data, instrumentation and process parameters.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing PMAOPS344
What does an assessment tool for PMAOPS344 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for PMAOPS344 needs to address all 72 unit components: 4 elements with 21 performance criteria, 1 performance evidence requirements, 45 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for PMAOPS344?
Auditori pulls the current release of PMAOPS344 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for PMAOPS344 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing PMAOPS344 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of PMAOPS344, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- PMAOPS101 — Read dials and indicators
- PMAOPS105 — Select and prepare materials
- PMAOPS201 — Operate fluid flow equipment
- PMAOPS202 — Operate fluid mixing equipment
- PMAOPS204 — Select and use utilities and services
- PMAOPS205 — Operate heat exchangers
- PMAOPS208 — Operate chemical separation equipment
- PMAOPS210 — Operate solids handling equipment
- PMAOPS213 — Package product/material
- PMAOPS216 — Operate local control system
- PMAOPS217 — Operate wet milling equipment
- PMAOPS220 — Monitor chemical reactions in the process
Your PMAOPS344 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate PMAOPS344 free