MSMBLIC002 — Licence to operate an advanced boiler
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for MSMBLIC002 must cover
73 assessable components: 5 elements (34 performance criteria), 16 performance evidence and 23 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Plan and prepare for work
- 1.1Follow standard operating procedures (SOPs)
- 1.2Comply with work health and safety (WHS) requirements at all times
- 1.3Identify potential workplace hazards and appropriate risk control measures consistent with appropriate standards to ensure the safety of personnel and equipment
- 1.4Locate and review appropriate records to prepare for boiler operation
- 1.5Identify the type of boiler with associated equipment and plan boiler operations according to procedures
- 1.6Identify appropriate personal protective equipment (PPE) in accordance with SOPs
- 1.7Identify suitable communication methods and confirm with appropriate personnel
2 Start up boiler
- 2.1Apply risk prevention and risk control measures to the work area according to procedures
- 2.2Select communication equipment and inspect for serviceability
- 2.3Select all necessary equipment and inspect for operational effectiveness according to procedures, including establishing water level
- 2.4Check boiler and associated equipment visually for any damage or defects and report and record any found according to procedures with appropriate action taken
- 2.5Vent boiler to atmosphere prior to start-up, as required
- 2.6Carry out pre-start up checks on the boiler and bring the boiler and associated equipment online safely according to procedures
- 2.7Start up boiler according to procedures
- 2.8Identify maintenance requirements and any visual faults and report according to procedures
- 2.9Confirm, complete and log all maintenance and/or repairs and associated isolations and make the equipment serviceable
3 Monitor boiler operation
- 3.1Diagnose operating status of the boiler and associated equipment
- 3.2Maintain operating log clearly and accurately according to procedures
- 3.3Monitor boiler, valves, fittings, pressure gauges combustion management systems, air heaters, superheaters and economisers (where fitted) according to procedures
- 3.4Blow boiler water level gauges through both steam and water sides
- 3.5Test standby plant and equipment according to procedures
- 3.6Conduct boiler water quality tests, where required, and record the results according to procedures
- 3.7Adjust boiler water chemicals after tests, where appropriate and required, according to procedures and notify downstream users, if necessary
- 3.8Activate the automatic blowdown and, where required, boiler is blown down to adjust total dissolved solids (TDS) levels to recommendations
- 3.9Communicate handover information regarding boiler status and associated equipment and operation clearly to relevant personnel according to procedures
- 3.10Respond immediately to any boiler emergency in accordance with procedures
4 Shut down boiler
- 4.1Shut down the boiler and associated equipment for inspection according to procedures, as required
- 4.2Identify maintenance requirements and report any visual faults according to procedures
- 4.3Clean boiler and associated equipment internally and externally to manufacturer recommendations and procedures, where required
- 4.4Complete isolations associated with in-service maintenance according to procedures
- 4.5Complete boiler operating log for shutdown
5 Store boiler in shutdown mode
- 5.1Identify storage time and condition of storage, where required
- 5.2Store boiler and associated equipment in safe condition for access in accordance with manufacturer recommendations and procedures
- 5.3Test stored boiler water and chemicals, where required, and handle in accordance with procedures, where storage is for extended periods
Performance evidence
- following work instructions, SOPs and safe work practices
- complying with Commonwealth, state and territory work, health and safety (WHS) legislation and regulations
- complying with Australian and industry standards, organisation workplace standards, policies, relevant codes of practice requirements at all times
- planning and preparing for work, including identifying potential hazards and implementing appropriate risk control measures
- identifying the type of standard or advanced boiler and associated equipment
- reading and interpreting maintenance records, operating logs and safety data sheets (SDS)
- conducting the appropriate pre-start up checks, including identifying all maintenance requirements and visual faults
- using appropriate tools, equipment and PPE in accordance with procedures
- completing all maintenance and rectification requirements in accordance with manufacturers’ and workplace procedures, including recording/reporting requirements
- completing the start-up procedures and bringing the boiler online
- monitoring the boiler and associated equipment, including conducting relevant tests and activities and adjusting boiler water quality in accordance with procedures
- interpreting advanced boiler operation tables and figures
- communicating handover of boiler status and associated equipment to appropriate personnel
- demonstrating emergency operating procedures
- identifying all boiler energy sources required to be isolated and made safe for maintenance, inspection and repairs
- applying advanced boiler cleaning and storage techniques.
Knowledge evidence
- safe work practices and procedures and use of PPE
- Commonwealth, state and territory WHS/OHS legislation and approved codes of practice relevant to standard and advanced boiler operation
- Australian and industry standards relevant to standard and advanced boiler operation
- basic principles of heat transfer and thermodynamics in relation to standard and advanced boiler operation
- standard and advanced boiler operation steam equipment operating principles and operating methods
- types and characteristics of multiple fuel systems for standard and advanced boilers
- types and characteristics of feedwater systems and treatment, including de-aerator
- types and use of equipment and fittings for operation and maintenance of boilers
- function, purpose and operation of the following: pre-heater superheater economiser air heater feedwater heater attemperator superheater safety valves economiser relief valves main steam stop valve
- standard and advanced boiler and auxiliary equipment characteristics and capabilities
- essential fittings required where more than one boiler is installed (e.g. battery of boilers)
- processes for confirming operational status of a boiler
- workplace communication techniques and procedures
- responsibilities for checking and testing advanced boilers
- location and inspection procedures and techniques for inspection and explosion doors
- steam and boiler hazards for cold start and handover
- hierarchy of risk control
- type and limitations of corrective action and/or adjustments that can be made in response to routine boiler operation problems and emergencies
- various harmful energy sources in standard and advanced boiler operation and the means to effectively isolate these energy sources and make them safe with particular consideration to advanced boilers
- modes of standard and advanced boiler storage and procedures for storing boiler in open or closed condition
- SDS and safe chemical handling and storage methods for boiler operation and cleaning
- procedures for cleaning boilers internally and externally, where required
- procedures for recording, reporting and maintenance of workplace records and information.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing MSMBLIC002
What does an assessment tool for MSMBLIC002 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MSMBLIC002 needs to address all 73 unit components: 5 elements with 34 performance criteria, 16 performance evidence requirements, 23 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for MSMBLIC002?
Auditori pulls the current release of MSMBLIC002 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MSMBLIC002 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing MSMBLIC002 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MSMBLIC002, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
Your MSMBLIC002 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate MSMBLIC002 free