MSL974029 — Operate an automated mineral analysis system
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for MSL974029 must cover
38 assessable components: 4 elements (20 performance criteria), 1 performance evidence and 16 knowledge evidence requirements, plus 1 foundation skills. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare automated analysis system for operation
- 1.1Confirm equipment status, shift priorities, work flow issues and/or specific client requirements with supervisor and other operators
- 1.2Plan or adjust work flow to suit maintenance or servicing as required
- 1.3Review job requests to identify samples/batches, required operating parameters and any special instructions/analyses for each
- 1.4Identify hazards, safety equipment and safe work procedures associated with samples, reagents, analytical methods and operating robotic arms
- 1.5Perform routine system checks at start of shift
2 Conduct or monitor loading of samples into system
- 2.1For systems with a manual in-feed station, prepare vials with the specified sample volume and load them in the correct sequence
- 2.2For fully automated systems, monitor sample in-feed station to ensure vials contain specified minimum volumes
3 Monitor and adjust system operation
- 3.1Adjust system operating parameters, such as furnace temperature, to suit specific batch requirements
- 3.2Monitor control screens continuously and respond promptly to error codes
- 3.3Conduct regular visual checks to ensure that system elements are operating correctly
- 3.4Interpret routine error codes to identify faulty system elements
- 3.5Take control of system and activate interlocks to isolate relevant system elements before investigating faults
- 3.6Clean and reposition robots, vials, crucibles or other system elements as necessary
- 3.7Use appropriate system checks and commands to reset system elements, re-enter sample data and resume operations
- 3.8Seek advice about dealing with any situation beyond scope of responsibility or knowledge
- 3.9Liaise with and assist relevant service personnel to ensure major breakdowns are rectified promptly
4 Maintain a safe work environment
- 4.1Use safe work practices, safety equipment and personal protective equipment (PPE) to ensure personal safety and that of others
- 4.2Clean and maintain system elements, maintain consumable stocks, and care for and store equipment as required
- 4.3Minimise the generation of waste and environmental impacts
- 4.4Segregate and dispose of wastes in accordance with workplace requirements
Performance evidence
- operated an automated mineral analysis system safely, reliably and efficiently for at least 3 different sets of operating conditions or 3 different types of samples.
Knowledge evidence
- importance of good customer relations, achieving production targets and minimising costs and rework
- purpose of analytical tests conducted in job role
- function and operation of automated system elements and flow chart for automated analysis process
- common mineral samples: pulverised solids, such as rocks, minerals, soils, sands and stream sediments; pulverised core and other drill samples
- automated analytical methods: thermal gravimetric analysis (TGA); x-ray fluorescence (XRF)
- workplace procedures for: specific samples, batches and clients (such as labelling, preparation, analysis, storage, transport and disposal); computer operation, including use of specific control screens, menus and control commands; common faults, routine system error codes and specified corrective actions for each
- cleaning/maintaining equipment and instruments used in job role
- preventing contamination of samples and equipment
- ensuring traceability of samples
- automated system elements: sample in-feed station, weigh stations, mould table, furnaces, robotic arms, conveyor belts, acid/ultrasound baths for cleaning crucibles, compressed air system
- routine system checks
- visual checks: presence of surface dust on system elements, particularly sensors; sample contamination during sample extraction from vials; cleanliness of crucibles before re-use
- typical routine system faults and corrective actions
- workplace and/or legal traceability requirements
- awareness of environmental sustainability issues as they relate to the work task
- legal, ethical and work health and safety (WHS) requirements specific to the work task.
Foundation skills
- Problem solving: to recognise potential issues caused by prior sample handling and/or preparation and rectify.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing MSL974029
What does an assessment tool for MSL974029 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MSL974029 needs to address all 38 unit components: 4 elements with 20 performance criteria, 1 performance evidence requirements, 16 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for MSL974029?
Auditori pulls the current release of MSL974029 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MSL974029 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing MSL974029 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MSL974029, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- MSL904003 — Perform standard calibrations
- MSL905004 — Perform non-standard calibrations
- MSL905005 — Create or modify calibration procedures
- MSL912002 — Work within a laboratory or field workplace
- MSL913004 — Plan and conduct laboratory/field work
- MSL914002 — Prepare practical science classes and demonstrations
- MSL915003 — Provide information to customers
- MSL915004 — Schedule laboratory work for a small team
- MSL916011 — Develop and maintain laboratory documentation
- MSL916012 — Manage and develop teams
- MSL916013 — Supervise laboratory operations in work or functional area
- MSL916014 — Maintain compliance in work or functional area
Your MSL974029 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate MSL974029 free