What an assessment for CPPFES3040 must cover

32 assessable components: 5 elements (18 performance criteria), 2 performance evidence and 12 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Plan and prepare for installation operation.

  • 1.1Interpret work instructions to clarify client needs and installation timeframes and location.
  • 1.2Discuss planned installation procedures with relevant persons to select suitable passive fire and smoke containment system to meet client and regulatory requirements.
  • 1.3Plan work activities to comply with relevant Australian Standards, NCC, regulatory, work health and safety (WHS) and workplace requirements.
  • 1.4Arrange access to worksite and communicate with responsible entity and affected persons to advise duration and impact of planned installation procedures and to ensure alternative safety arrangements are implemented.
  • 1.5Select and use required personal protective equipment (PPE) and identify and control hazards in the work area according to workplace requirements.
  • 1.6Measure installation site and verify calculations against installation requirements for selected fire and smoke stopping products according to manufacturer requirements.
  • 1.7Identify and assemble required tools, equipment, components and fireproofing or fire-stopping materials according to manufacturer and workplace requirements.

2 Prepare fireproofing substrate or fire-stopping opening.

  • 2.1Check structural or penetrated elements to confirm compliance with required smoke resistance or fire resistance level.
  • 2.2Prepare fireproofing substrate or fire-stopping opening according to manufacturer requirements.
  • 2.3Measure and prepare materials for installation of fireproofing or fire-stopping system according to manufacturer requirements.

3 Install passive fire and smoke containment system.

  • 3.1Install passive fire and smoke containment system according to manufacturer requirements.
  • 3.2Inspect and test passive fire and smoke containment system to verify quality of installation and workmanship to meet client, NCC and workplace requirements.
  • 3.3Take actions required to rectify quality issues or defects to meet client, NCC and workplace requirements.

4 Label or mark and certify passive fire and smoke containment system.

  • 4.1Assess installation and label or mark according to the relevant Australian Standard, NCC and manufacturer requirements.
  • 4.2Complete relevant schedule of evidence of compliance according to the relevant Australian Standard, NCC and workplace requirements.

5 Finalise installation operation.

  • 5.1Complete and distribute installation documentation according to workplace requirements.
  • 5.2Check tools and equipment for faults, wear or damage and rectify or report problems according to workplace requirements.
  • 5.3Leave client premises in a clean and tidy condition.

Performance evidence

  • installing different types of fireproofing to structural steel and ductwork: spray, intumescent paint, board
  • installing fire-stopping systems

Knowledge evidence

  • action to take when a breach of regulation, work health and safety (WHS) or other policy occurs when installing fire and smoke stopping products and systems
  • dangers of incorrect installation of passive fire and smoke containment systems
  • implications of not complying with National Construction Code (NCC) and manufacturer requirements when installing fire and smoke stopping products and systems
  • key features of legislation, regulations, NCC and Australian Standards relevant to the installation of fire and smoke stopping products and systems: - design, construction, selection, installation and performance requirements for installed fire and smoke stopping products and systems - requirements for labelling and certifying installed fire and smoke stopping products and systems, including types of labels and documents to be used when marking and certifying products and systems - records and documentation
  • meaning of common technical terms used in the installation of passive fire and smoke containment systems: - plumb, level, square and perpendicular - mix ratio, density, wet film thickness, dry film thickness, section factor (Hp/A), exposed surface to mass (ESM) ratio and critical temperature - fire-rated walls, masonry, concrete, plasterboard and shaft wall - fire-rated floors and floor ceiling systems - penetration dimensions, i.e. width, height, depth and orientation - ambient and cold smoke, medium smoke and elevated and hot smoke - intumescent products and ablative products - clearance, field of application, fire resistance levels, incipient spread of fire, spread of flame indices, fire test report, assessments and letters of opinion - passive fire and smoke containment labelling types
  • principles of passive fire protection related to overall fire safety and containment systems specific to passive fire and smoke containment systems
  • procedures for determining fire resistance levels and smoke resistance levels
  • fireproofing and fire-stopping variables, including types, components and fire barrier types
  • types and purpose of tools and equipment used when installing fire and smoke stopping products and systems: - hand and power tools - personal protective equipment (PPE)
  • types of quality defects that may cause loss of fire or smoke resistance when installing fire and smoke stopping products and systems
  • types, purpose and key physical features of a range of fire and smoke stopping products and systems: - access panels and hatches - ceiling and partition systems - control and expansion joints - duct and damper penetration protection - duct fireproofing and protection - fabric and timber protection, including impregnated or sprayed - fire-resistant mortars and grouts, including load bearing and non-load bearing - fire-resistant pillows, including intumescent and non-intumescent - fire stop collars, including cast in, retrofit and wall - fire-rated air transfer grilles - fire-rated sealants, caulks and putties, including acrylic, polyurethane and silicone - fire-resistant boards, including calcium silicate and vermiculite - industrial fire protection - intumescent dampers and seals - intumescent paints and coatings, other than those used for fireproofing structural steel - linear gaps seals, including impregnated foams, tapes, intumescent gaskets and sealants - materials into or onto which passive fire and smoke containment products are installed - mechanical and intumescent fire dampers - openings in structural elements - penetration solutions - protection against spread of flame - smoke dampers - structural steel fireproofing - unplasticised polyvinyl chloride (UPVC) and plumbing penetrations
  • workplace requirements for installing fire and smoke stopping products and systems: - maintenance of tools and equipment - WHS, including hazard and risk identification and control.

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing CPPFES3040

What does an assessment tool for CPPFES3040 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for CPPFES3040 needs to address all 32 unit components: 5 elements with 18 performance criteria, 2 performance evidence requirements, 12 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for CPPFES3040?

Auditori pulls the current release of CPPFES3040 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for CPPFES3040 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing CPPFES3040 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of CPPFES3040, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.