What an assessment for CPPFES2039 must cover
28 assessable components: 4 elements (15 performance criteria), 1 performance evidence and 12 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Plan and prepare for service operation.
- 1.1Read work instructions to clarify service timeframes, client needs, and site and passive fire and smoke containment product and system locations.
- 1.2Discuss planned service procedures with relevant persons to clarify client needs and expectations.
- 1.3Plan work activities to comply with relevant Australian Standards, NCC, regulatory, work health and safety (WHS) and workplace requirements.
- 1.4Identify potential and actual breaches of rules and regulations associated with work instructions and take required action to ensure compliance according to regulatory and workplace requirements.
- 1.5Select and use required personal protective equipment (PPE).
- 1.6Arrange access to worksite and communicate with responsible entity and affected persons to advise duration and impact of planned service procedures and to ensure alternative safety arrangements are implemented.
- 1.7Identify and prepare to control hazards in the work area according to workplace requirements.
2 Identify passive fire and smoke containment installations and systems.
- 2.1Identify passive fire and smoke containment systems according to function, operation and location.
- 2.2Identify and locate installed product components of passive fire and smoke containment installations and systems according to design, operation and function.
3 Inspect and test passive fire and smoke containment installations and systems.
- 3.1Inspect passive fire and smoke containment system products according to the relevant maintenance schedule.
- 3.2Check passive fire and smoke containment system products for marking and labelling against requirements of the relevant Australian Standard.
- 3.3Identify potential or actual impediments to performance of passive fire and smoke containment system according to regulatory and workplace requirements.
- 3.4Record identified defects and non-compliances according to regulatory and workplace requirements.
4 Finalise service operation.
- 4.1Complete service documentation and report outstanding defects, non-compliances and potential or actual impediments to performance according to Australian Standards, regulatory and workplace requirements.
- 4.2Leave client premises in a clean and tidy condition.
Performance evidence
- To demonstrate competency, a candidate must meet the elements and performance criteria of this unit by identifying, inspecting and testing passive fire and smoke containment products and systems installed to protect service penetrations and control joints in five different buildings.
Knowledge evidence
- action to take when a breach of regulation, work health and safety (WHS) or other policy occurs when identifying, inspecting and testing passive fire and smoke containment products and systems
- dangers of incorrect installation of passive fire and smoke containment products and systems
- implications of not complying with regulatory requirements when inspecting and testing passive fire and smoke containment products and systems
- key features of legislation, regulations, codes and Australian Standards relevant to identifying, inspecting and testing passive fire and smoke containment products and systems: - maintenance schedules - National Construction Code (NCC) and deemed-to-satisfy requirements - records and documentation
- operational requirements for inspecting and testing passive fire and smoke containment products and systems
- passive fire and smoke containment variables, including types, products and solutions
- principles of passive fire protection related to overall fire safety systems
- procedures for determining fire resistance levels
- technical terms relating to inspecting and testing passive fire and smoke containment products and systems
- types of damage, defects and modifications to fire and smoke stopping products and systems that may cause loss of fire resistance
- types, purpose and key physical features of a range of passive fire and smoke containment products and systems: - access panels and hatches - ceiling and partition systems - control and expansion joints - duct and damper penetration protection - duct fireproofing and protection - fabric and timber protection, including impregnated or sprayed - fire-resistant mortars and grouts, including load bearing and non-load bearing - fire-resistant pillows, including intumescent and non-intumescent - fire stop collars, including cast in, retrofit and wall - fire-rated air transfer grilles - fire-rated sealants, caulks and putties, including acrylic, polyurethane and silicone - fire-resistant boards, including calcium silicate and vermiculite - industrial fire protection - intumescent dampers and seals - intumescent paints and coatings, other than those used for fireproofing structural steel - linear gaps seals, including impregnated foams, tapes, intumescent gaskets and sealants - materials into or onto which passive fire and smoke containment products are installed - mechanical and intumescent fire dampers - openings in structural elements - penetration solutions - protection against spread of flame - smoke dampers - structural steel fireproofing - unplasticised polyvinyl chloride (UPVC) and plumbing penetrations
- workplace requirements for identifying, inspecting and testing passive fire and smoke containment products and systems: - maintenance of tools and equipment - WHS, including hazard and risk identification and control.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing CPPFES2039
What does an assessment tool for CPPFES2039 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for CPPFES2039 needs to address all 28 unit components: 4 elements with 15 performance criteria, 1 performance evidence requirements, 12 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for CPPFES2039?
Auditori pulls the current release of CPPFES2039 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for CPPFES2039 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing CPPFES2039 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of CPPFES2039, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- CPPFES2003 — Safely move loads and dangerous goods
- CPPFES2004 — Identify and report on types of installed fire safety equipment and systems
- CPPFES2005 — Demonstrate first attack firefighting equipment
- CPPFES2006 — Prepare for installation and servicing operations
- CPPFES2007 — Maintain quality of work and promote continuous improvement
- CPPFES2010 — Inspect and test fire hose reels
- CPPFES2011 — Install portable fire extinguishers, fire cabinets and fire blankets
- CPPFES2016 — Inspect, test and maintain delivery layflat fire hoses
- CPPFES2020 — Conduct routine inspection and testing of fire extinguishers and fire blankets
- CPPFES2021 — Inspect, test and maintain fire extinguishers
- CPPFES2025 — Inspect, test and maintain gaseous fire-suppression systems
- CPPFES2026 — Inspect and test emergency and exit lighting systems
Your CPPFES2039 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate CPPFES2039 free