AVIJ0002Conduct quality control operations related to refuelling and defuelling aircraft

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for AVIJ0002 must cover

66 assessable components: 5 elements (29 performance criteria), 17 performance evidence and 20 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Conduct dispenser sampling processes

  • 1.1Fuel samples are taken from dispenser for visual testing at the commencement of routine operations in accordance with workplace procedures and regulatory requirements
  • 1.2Fuel samples are taken from dispenser for visual testing during fuelling operations in accordance with workplace procedures and regulatory requirements

2 Conduct fueller sampling processes

  • 2.1Fuel samples are taken from fueller for visual testing at the commencement of routine operations and during fuelling operations in accordance with workplace procedures and regulatory requirements
  • 2.2Additional samples are taken from fueller after defuelling operations, vehicle washing, maintenance and rain events

3 Conduct visual check of fuel samples

  • 3.1Fuel sample is inspected and colour identified and interpreted to determine grade of fuel in accordance with workplace procedures and established colour criteria
  • 3.2Sample is inspected for free water and dirt particles in accordance with workplace procedures and established manual or automated processes
  • 3.3Water detector capsules are used to check for suspended water in accordance with manufacturer instructions and workplace procedures
  • 3.4Results of visual checks are recorded and reported in accordance with workplace procedures and regulatory requirements

4 Test membrane filtration (millepore sampling)

  • 4.1Hydrant dispenser vehicle is positioned at test rig and is interlocked/chocked in accordance with workplace procedures
  • 4.2Fuellers are tested independent of test rig by circulating product through delivery hose back to tank to achieve required flow rates
  • 4.3Bonding leads are attached in accordance with workplace procedures
  • 4.4Fueller/dispenser delivery hoses are connected to achieve a flow rate of at least 50% of rated flow of filter
  • 4.5Hydrant dispenser lanyard is connected to pit valve and inlet hose is connected in accordance with workplace procedures
  • 4.6Colorimetric capsule is loaded in accordance with manufacturer instructions and workplace procedures
  • 4.7Checks are made to ensure capsule is located in housing with millepore monitor inlet facing upstream
  • 4.8Apparatus is connected to filter outlet millepore sample connection or nozzle millepore sample point
  • 4.9Pressure and flow rate are adjusted to workplace specifications
  • 4.10Apparatus is flushed
  • 4.11Calorimetric test samples are drawn monthly in accordance with sampling schedules
  • 4.12Gravimetric and microbiological tests are drawn every three months in accordance with sampling schedules, ensuring that initial sample is drawn for gravimetric test then gravimetric capsule is replaced with microbiological capsule, and another sample is drawn in accordance with workplace procedures
  • 4.13Apparatus is disconnected and capsule is removed
  • 4.14Gravimetric and microbiological samples are labelled and dispatched to laboratory in accordance with workplace procedures
  • 4.15Colorimetric assessment is conducted in accordance with manufacturer instructions and workplace procedures
  • 4.16Test results are documented in accordance with workplace procedures and regulatory requirements

5 Measure pressure differential on filter vessels

  • 5.1Gauge is checked in accordance with manufacturer instructions and workplace procedures
  • 5.2Flow through vessel into aircraft or test rig is started in accordance with workplace procedures
  • 5.3Pressure differential at maximum flow rate obtained is read
  • 5.4Results are analysed and recorded in accordance with workplace procedures and regulatory requirements
  • 5.5Where differential pressure exceeds filter manufacturer recommended differential pressure at flow rates above 50% of the maximum rated flow of filter vessel, situation is reported immediately to supervisor for investigation in accordance with workplace procedures and regulatory requirements

Performance evidence

  • adapting to differences in equipment and operating environment in accordance with standard operating procedures (SOPs)
  • applying precautions and required action to minimise, control or eliminate identified hazards related to fuel handling procedures
  • applying relevant legislation and workplace procedures
  • communicating effectively with others
  • completing relevant documentation
  • identifying and correctly using relevant
  • implementing contingency plans
  • implementing work health and safety (WHS) procedures and relevant regulations
  • modifying activities depending on workplace contingencies, situations and environments
  • monitoring and anticipating operational problems and hazards and taking appropriate action
  • monitoring work activities in terms of planned schedule
  • operating electronic communications equipment to required protocol
  • reading, interpreting and following relevant regulations, instructions, procedures, information and signs
  • reporting and/or rectifying problems, faults or malfunctions promptly in accordance with workplace procedures
  • selecting and using required personal protective equipment (PPE) conforming to industry and WHS standards
  • working collaboratively with others
  • working systematically with required attention to detail without injury to self or others, or damage to goods or equipment

Knowledge evidence

  • aircraft fuelling/defuelling operations quality control principles and processes
  • conduct of dispenser sampling processes
  • conduct of fueller sampling processes
  • conduct of visual check of fuel samples
  • correct fitment and wearing of required safety and PPE, including:
  • approved uniform/clothing
  • gloves
  • hearing protection
  • high visibility clothing
  • mask or respirator
  • safety glasses
  • safety headwear and footwear
  • safety vest
  • manufacturer instructions for equipment used in quality control processes
  • membrane filtration testing (millepore sampling) procedures
  • problems that may occur when conducting aircraft refuelling/defuelling quality control operations and appropriate action that should be taken in each case
  • relevant WHS and environmental procedures and regulations
  • relevant sections of Civil Aviation Safety Regulations (CASRs) and Civil Aviation Orders and other regulations for aircraft refuelling and defuelling quality control processes carried
  • risks that exist when conducting aircraft refuelling/defuelling quality control operations and related risk control procedures and precautions
  • workplace procedures for conducting aircraft refuelling and defuelling quality control operations

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing AVIJ0002

What does an assessment tool for AVIJ0002 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for AVIJ0002 needs to address all 66 unit components: 5 elements with 29 performance criteria, 17 performance evidence requirements, 20 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for AVIJ0002?

Auditori pulls the current release of AVIJ0002 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for AVIJ0002 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing AVIJ0002 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of AVIJ0002, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your AVIJ0002 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate AVIJ0002 free