AURKTR101 — Diagnose and repair electronic over hydraulic control systems
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for AURKTR101 must cover
38 assessable components: 4 elements (16 performance criteria), 7 performance evidence and 9 knowledge evidence requirements, plus 6 foundation skills. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to diagnose and repair electronic over hydraulic control system
- 1.1Identify job requirements from workplace instructions
- 1.2Identify required information for diagnosis activity
- 1.3Analyse diagnostic options and source testing strategy to identify cause of fault using workplace and manufacturer procedures
- 1.4Identify hazards and environmental issues associated with diagnose and repair activity, assess potential risks and implement control measures in line with workplace policies and procedures
- 1.5Identify tools and equipment required for testing strategy and establish serviceability according to workplace procedures
2 Diagnose electronic over hydraulic control system
- 2.1Implement diagnostic tests set out in testing strategy according to manufacturer and workplace procedures, and workplace health and safety requirements
- 2.2Identify cause of fault through analysis of diagnostic test results
- 2.3Confirm and report cause of fault according to workplace procedures
- 2.4Develop and report recommendations for necessary repairs according to workplace procedures
3 Repair electronic over hydraulic control system
- 3.1Identify required information for repair activity
- 3.2Identify tools, equipment and materials required for repair activity and establish serviceability according to workplace procedures
- 3.3Carry out repairs according to workplace and manufacturer procedures, manufacturer specifications, workplace health and safety and environmental requirements
- 3.4Carry out post-repair testing according to workplace procedures, workplace health and safety and environmental requirements
4 Complete work processes
- 4.1Conduct final inspection according to workplace procedures and confirm vehicle or machinery is ready for use
- 4.2Clear work area and dispose of or recycle materials according to workplace procedures
- 4.3Complete documentation according to workplace procedures
Performance evidence
- hydraulic proportional control solenoids (flow, pressure and directional)
- joysticks, potentiometer or touchscreens
- sensors and feedback devices
- electronic control amplifier units
- electronic over hydraulic circuitry
- servo control valves (flow, pressure and directional)
- electronic control unit (ECU)
Knowledge evidence
- methods to locate and interpret information required to diagnose and repair electronic over hydraulic control systems, including: information provided by customers and supervisors; manufacturer specifications and procedures or equivalent documentation
- workplace procedures required to diagnose and repair electronic over hydraulic control systems, including: establishing serviceability of tools and equipment; documentation procedures; housekeeping procedures, including: examination of tools and equipment; storage of equipment; identification, tagging and isolation of faulty equipment; disposal of excess materials; recycling procedures
- workplace health and safety (WHS) requirements relating to diagnosing and repairing electronic over hydraulic control systems, including procedures for: working with high pressure fluid hazards; isolating and stabilising machines
- environmental requirements relating to diagnosing and repairing electronic over hydraulic control systems
- operating principles of electronic over hydraulic control systems, including operating principles of flow, pressure and directional control in: electronic open loop circuits; electronic semi open loop circuits; electronic closed loop circuits
- purpose and operation of systems and components, including: hydraulic proportional control solenoids; servo control units; sensors; feedback devices; electronic control amplifier units; joysticks; electronic control units; electronic over hydraulic circuitry
- diagnostic testing procedures for electronic over hydraulic control systems, including: electronic system analysis while using industry-relevant test equipment; component wear analysis; system operation analysis
- repair procedures for electronic over hydraulic control systems, including procedures for: testing electronic devices; replacing electronic devices and adjusting the following: maximum and minimum flow points; dither; opening ramps; closing ramps
- post-repair testing procedures for electronic over hydraulic control systems.
Foundation skills
- Learning: • Locates required sources of information efficiently • Develops a sequenced plan for a specific task
- Reading: • Organises and interprets technical information from workplace procedures, manufacturer procedures and manufacturer specifications • Interprets electronic over hydraulic control symbols and circuits.
- Oral communication: • Clarifies instructions • Obtains information from customers and supervisors.
- Numeracy: • Measures electronic over hydraulic control system components • Uses mathematical operations • Calculates deviations and tolerances from manufacturer specifications • Interprets system hydraulic pressure gauges • Interprets electrical test meters.
- Planning and organising: • Plans own work requirements • Prioritises actions to achieve required outcomes • Ensures tasks are completed within workplace timeframes.
- Technology: • Operates diagnostic and testing equipment.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing AURKTR101
What does an assessment tool for AURKTR101 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for AURKTR101 needs to address all 38 unit components: 4 elements with 16 performance criteria, 7 performance evidence requirements, 9 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for AURKTR101?
Auditori pulls the current release of AURKTR101 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for AURKTR101 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing AURKTR101 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of AURKTR101, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Your AURKTR101 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate AURKTR101 free